• Title/Summary/Keyword: 습도 변화

Search Result 1,142, Processing Time 0.033 seconds

Humidity Dependence of the Residual Stress of Diamond-like Carbon Film (습도에 따른 다이아몬드성 카본필름의 잔류응력 변화에 대한 연구)

  • Lee Young-Jin;Kim Tae-Young;Lee Kwang-Ryeol;Yang In-Sang
    • Journal of the Korean Vacuum Society
    • /
    • v.13 no.4
    • /
    • pp.157-163
    • /
    • 2004
  • Dependence of residual compressive stress of diamond-like carbon (DLC) films on relative humidity was investigated. Polymeric, graphitic and diamond-like carbon films were prepared by r.f.-PACVD using methane or benzene with the negative self bias voltage of the substrate ranging from -100 to -800 V. In-situ measurements of the residual stress were carried out in an environment chamber where the relative humidity was varied from 10% to 90%. In dense DLC film of high residual compressive stress and hardness, we could not observe any change in the residual compressive stress with relative humidity. However, in the cases of graphitic and polymeric DLC films, abrupt change in the residual stress occurred by changing the relative humidity. The quantity of the stress change was inversely proportional to the film thickness, which means that the stress change with humidity is not due to the penetration of the water molecule into the film structure, but due to surface interaction between water molecules and film surface.

Changes in the Amount of PEG Free-Flowing Back from PEG-Treated Waterlogged Archaeological Wood and the Compressive Strength According to Relative Humidity Conditions (습도조건에 따른 PEG 처리 수침고목재의 PEG 용출량 및 압축강도 변화)

  • Jo, Ah Hyeon;Lee, Kwang-Hee;Choi, Tae-Ho;Go, In Hee;Seo, Jeong-Wook
    • Journal of Conservation Science
    • /
    • v.36 no.3
    • /
    • pp.225-235
    • /
    • 2020
  • The present study aimed to monitor changes in the amount of PEG free-flowing back from PEG-treated woods and compressive strength changes with change in relative humidity from 90% to 30%. The change in the relative humidity was done 3 times. For the current study, water-logged wood (Prinus group) was used and the wooden blocks cut out of it were subjected to 3 different impregnation methods combined with different drying conditions as follows: 1) impregnating with 80% PEG#4000 followed by drying in nature (hereafter PEG80), 2) impregnating with 40% PEG#4000 and then drying in vacuum freeze drying equipment (hereafter PEG40), and 3) impregnating with 40% PEG#4000 in t-butanol, followed by drying in the vacuum freeze drying equipment (hereafter TB40). It was verified that most of the PEG was free-flowing back from the PEG-treated woods; however, a small amount of left PEG was observed on the lumen surface. The amount of PEG free-flowing back from the PEG-treated woods increased whenever the relative humidity changes from 90% to 30%. The compressive strengths of PEG80 and TB40 were increased whenever the relative humidity changed from 90% to 30%, whereas PEG40 decreased. The current study showed how to control the relative humidity to effectively manage PEG-treated waterlogged woods.

Analysis of Thermal Performance of Ardisia Species Used for Improvement of Indoor Environment (실내환경 개선을 위한 Ardisia속 식물의 열 성능 평가)

  • Lee, Na Young;Han, Seung Won;Joo, Na Ri;Lee, Jong Suk
    • FLOWER RESEARCH JOURNAL
    • /
    • v.16 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • This study investigated the changes of indoor thermal environment by Ardisia species planted in indoor space. Three Ardisia species (Ardisia japonica, Ardisia crenata and Ardisia pusilla) were used in this study and differences of temperature and relative humidity were ascertained in an empty chamber with and without plants. In high temperatures over $24^{\circ}C$, Ardisia species cooled down chamber more as compared to the control without plants, but there were no significant differences among Ardisia species. Ardisia crenata showed high relative humidity of $57.3{\pm}3.1%$ during most of the day time and $60.8{\pm}2.5%$ at low temperatures. However, Ardisia japonica and Ardisia pusilla showed $54.7{\pm}1.18%$ and $52.5{\pm}2.4%$, respectively, on the average, and they maintained comfortable relative humidity during most of the day time. When the setting temperature was decreased from 28 to $26^{\circ}C$, Ardisia species showed 7.5~13.6 times greater cooling efficiency as compared to the control without plants, and at low temperatures the chamber without plants showed higher themal energy than the chamber with plants. Ardisia species were effective on cooling down the temperature at high temperatures and they showed a tendency to maintain proper temperatures at low temperatures.

Compressive Strength Reduction Characteristics of Linerboard as Influenced by Temperature and Humidity (온도 및 습도 변화에 따른 라이너원지의 압축강도 열화에 관한 연구)

  • 이준호;김수일;하영선
    • Food Science and Preservation
    • /
    • v.6 no.3
    • /
    • pp.303-307
    • /
    • 1999
  • Compressive strength reduction characteristics of 4 different linerboards(SC, KA, SK and IK) as influenced by temperature and humidity were investigated by ring crush test. No significant effect of temperature on the reduction of compressive strength was found for samples prepared at 5$^{\circ}C$ and 30$^{\circ}C$. At the relative humidity of 66 percents, IK linerboard showed the lowest reduction of the compressive strength. At the relative humidity of 93 percents, KA linerboard lost 40 percents of its initial compressive strength while SK linerboard lost its strength up to 56 percents. The result indicated that KA linerboard was the most cost effective and material with the highest compressive strength among tested linerboards.

  • PDF

Micro humidity sensor with poly imide sensitive layer (폴리이미드를 감지막으로 한 마이크로 정전용량형 습도센서)

  • Shin, P.K.;Cho, K.S.;Park, G.B.;Yuk, J.H.;Park, J.K.;Im, H.C.;Ji, S.H.;Kim, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1898-1899
    • /
    • 2005
  • 반도체 집적회로 공정에서 사용되는 폴리이미드 포토레지스트(P12723, Dupont)를 감습막으로 사용하는 마이크로 습도센서 소자를 제작하였다. 마이크로 습도센서는 실리콘 웨이퍼 기판 위에 $SiO_2$ 박막을 건식열산화 공정으로 제작하고, Al 박막을 포토리소그라피 공정으로 패터닝 한 IDT (Interdigital Transducer)를 전극 위에 폴리이미드 포토레지스트를 공정변수를 다양하게 조절하면서 감습막으로 제작하였다. 폴리이미드 감습막은 스핀코팅법으로 제작하였으며, 회전수를 조절하여 두께를 변화시켰다. 완성된 마이크로 습도센서 소자의 상대습도 변화$(10{\sim}90% RH)$에 따른 정전용량 값 변화를 항온항습조 내에서 다양한 온도에서 HP4192A Impedance Analyzer를 사용하여 조사함으로써, 폴리이미드 포토레지스트를 사용하는 마이크로 정전용량형 습도센서의 제작 가능성을 검토하였다. 폴리이미드 정전용량형 마이크로 습도센서는 다양한 인가 전원 주파수에서 기준 센서로 사용된 상용 Vaisala Hygrometer와 유사한 감습특성 및 응답특성을 보였다.

  • PDF

A Study on the Change of Humidity by City Size in South Korea (한국의 도시 규모별 습도 변화에 관한 연구)

  • Ko, Myungchan;Lee, Seungho
    • Journal of the Korean Geographical Society
    • /
    • v.48 no.1
    • /
    • pp.19-36
    • /
    • 2013
  • This study aimed to investigate the change of humidity by city size in South Korea. Using daily mean relative humidity and water vapor pressure during the period of 1954~2011 for 14 weather stations in South Korea, the change of humidity by city size was analyzed. The change of relative humidity had a continuous decreasing trend for the period of 1954~2011. The decreasing trend in large city was bigger than these of rural one. The seasonal relative humidity was significantly changed in spring and winter. The change of water vapor pressure was rarely changed significance of the results by city size. It was not shown the result to constant trend by city size. There was a negative correlation between relative humidity and mean temperature. And change of relative humidity was correlated with city size. Moreover, there was not correlation between relative humidity and water vapor pressure by city size. The decreasing trend of relative humidity was similar to increasing trend of temperature by urbanization. However, there was not shown significant result of water vapor pressure.

  • PDF

Experimental Study on Capacity Variation of Paving Materials with TiO2 in Wet Condition (광촉매 이산화티타늄(TiO2)을 혼합한 도로 포장재의 습윤 조건에서의 성능 변화에 관한 실험적 연구)

  • Seo, Dawa;Yun, Tae Sup
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.5
    • /
    • pp.49-55
    • /
    • 2016
  • This study aims to present the practical Nitrogen monoxide (NO) removal capacity of cement mortar with Titanium dioxide ($TiO_2$) which is one of the paving materials by considering the environment of pavement in urban areas. NO removal capacity test under designated conditions of humidity of inflow gas and the test with variation of the degree of saturation of specimen were conducted. In the test for humidity, dry specimen is subject to the test and NO removal ratio was observed. Humidity-NO removal ratio curve is a log normal distribution in shape, and the maximum NO removal ratio appears at specific humidity. NO removal capacity test relying on the degree of saturation was carried out with wet specimen to reflect the unsaturated pavement by rainfall and domestic sewage. Wet specimen presents less NO removal capacity than dry specimen and the recovering evolution of NO removal capacity follows evaporation. Moreover, $TiO_2$ under the specific depth of specimen hardly contributes to NO removal capacity.

Damage of Overlaid Concrete Structures Subjected to Humidity Changes in the Atmosphere (습도 변화에 따른 콘크리트 덧씌우기 보수체의 손상분석)

  • 윤우현
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.766-773
    • /
    • 2002
  • The failure phenomenon of overlaid concrete structures, such as surface crack, and peel-off failure, shear bond failure in the end contact zone, was investigated due to humidity changes. To investigate this failure phenomenon, the surface tensile stress, and the shear stress, the vertical tensile stress in the contact zone were analysed using the non-linear stress-strain relationship of material such as strain-hardening- and strain-softening diagrams. Overlay thickness and overlay material were the main variables in the analyses. It is assumed that the initial surface humidity of overlaid concrete structures was 100% r.H. With a atmospheric humidity of 55% r.H. and two load cases for drying(LCI), curing and drying(LC2), the stress states of overlaid concrete structures were calculated. The result shows that only fictitious cracks occurred in the overlay surface of CM2O, ECM25, and no shear bond failure occurred in the contact zone without CM2O. The peel-off failure was proved to be the main cause of the damage in the overlaid concrete structures. Only for overlay thickness of 1cm occurred no peel-off failure in the case of drying after a long-term public use(LC1). In the case of curing and drying during overlay work(LC2) occurred the peel-off failure within 1.5days for all the overlaid concrete structures.

Humidity Sensor using Polyvinylpyrrolidone-Coated Mach-Zehnder Interferometer in Planar Lightwave Circuit (폴리비닐피롤리돈이 코팅된 마하젠더 간섭계 기반의 평판형 광도파로 습도센서)

  • Kim, Ju Ha;Kim, Myoung Jin;Jung, Eun Joo;Hwang, Sung Hwan;Lee, Woo Jin;Choi, Eun Seo;Rho, Byung Sup
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.5
    • /
    • pp.251-255
    • /
    • 2013
  • In this paper, the characteristics of a humidity sensor implemented by Mach Zehnder Interferometer (MZI) in a Planar Lightwave Circuit (PLC) have been designed and demonstrated. The humidity outside is detected with polyvinylpyrrolidone (PVP) coated on the etched arm of the MZI. The length of the etched arm is 10 mm and the PVP was coated by dip-coating into the etched region. As the refractive index of the PVP changes with the surrounding humidity, the PVP-coated humidity sensor presented changes in the interferogram depending on RH (Relative Humidity) around the PLC. The measured results show that the proposed humidity sensor works successfully in the range of 30% to 80% of RH.

Component-Level Humidity Correction for Gas Turbine Engine Using Map Transposition Technique (특성 곡선 전치 기법을 이용한 가스 터어빈 엔진의 구성품 수준 습도 보정)

  • 이시우;정명균;임진식
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.3
    • /
    • pp.83-94
    • /
    • 2000
  • A systematic humidity correction technique that can be used for any type of engine control mode is developed to predict the variation of engine performance due to inlet humidity. Limitation of conventional method is rot identified and then, a new method is proposed to take into account the humidity effects on each engine component characteristics and to find the variation of equilibrium running point through a re-match process between the components with a given engine control variable depending on the humidity of inlet. Comparisons are made between two methods for a single spool gas turbine engine, and it was found that the conventional method leads to invalid correction when a physical variable such as rotational speed is controlled for engine operation in humid environment. It was also found that the accuracy of the conventional method depends on the engine control mode and the engine configuration whereas the proposed method can be used for any type of engine control mode and engine configuration.

  • PDF