• 제목/요약/키워드: 습공기선도

검색결과 4건 처리시간 0.024초

습공기선도 상에 20 종류의 상태 및 과정 값의 작도 (Drawing of Twenty Kinds of State and Process on Psychrometric Chart)

  • 김덕진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1201-1206
    • /
    • 2008
  • Psychrometric chart displays graphically the thermophysical properties of moist air, so it is very conveniently used in air-conditioning and refrigeration. On general psychrometric chart, there are dry bulb temperature, web bulb temperature, absolute humidity ratio, relative humidity, specific enthalpy, specific volume, sensible heat factor, and enthalpy-humidity difference ratio. However, various state and process values besides aboves can be plotted on psychrometric chart. In this study, we developed the software drawing twenty kinds of lines, that is vapor pressure, mole fraction ratio of vapor, dew point temperature, degree of saturation, density, specific entropy, specific exergy, contact or bypass factor, uncomfort index, discomposition index, predicted mean vote index, predicted percent dissatisfied, and so on. We wish to this software is a help to design, analysis and education.

  • PDF

입구공기 안개법에 의한 공기압축기의 증발냉각도와 출력이득에 관한 연구 (ANALYTICAL STUDY ON EVAPORATIVE COOLING POTENTIAL AND POWER GAINS OF AIR COMPRESSORS BY INLET FOGGING)

  • ;김동선;이해동;권준경;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2637-2641
    • /
    • 2008
  • The ever increasing demand for power and the shortages encountered during summer calls for the implementation of strategies for power saving in industry. Inlet fogging of gas turbine engines is quite popular due to the ease of installation and the relatively low initial cost compared to other inlet cooling methods. In the present investigation, a detailed analysis is carried out on the basis of coincident wet bulb and dry bulb temperature data of a compressed air plant from April to October, 2007 to determine the evaporative cooling potential for the period. The power gain that can be obtained by employing inlet fogging of the air compressors is analyzed based on the real climatic data at several sites in Korea. An experimental set-up was constructed and tests were carried out with the standard impaction pin nozzle. The experimental results were found to match with the theoretical calculations.

  • PDF

기화방열식 Cool Roof Fan의 냉풍효과에 대한 연구 (A Study of the Cooling Effect of an Evaporation-Type Cool Roof Fan)

  • 김영식;정한식;정효민;최순호
    • 대한기계학회논문집B
    • /
    • 제40권3호
    • /
    • pp.191-200
    • /
    • 2016
  • 환기는 자연환기와 강제환기로 분류되며, 최근에는 하절기에 작업장의 환경개선을 위해 냉각된 공기를 공급하는 환기를 적용하는 경우가 많아지고 있다. 하지만 대규모의 작업장에 냉각된 공기를 공급하기 위해서는 많은 에너지가 필요하며, 이를 보완하기 위해 물의 증발열을 이용하여 공기를 냉각시킨 후 공급하는 환기장치의 도입사례가 증가하고 있으며, 본 실험연구는 부산의 모 신발공장에 실제 적용된 기화방열식 환기장치의 성능을 평가한 사례연구로서 하절기에 외부의 대기온도에 대해 어느 정도의 냉각능력을 구현할 수 있는지 측정하였다. 실험결과로부터 하절기에 약 $6{\sim}7^{\circ}C$ 정도의 냉각효과를 구현하지만 급기의 상대습도가 매우 높아짐을 정량적으로 측정할 수 있었다. 실험결과에 의하면 기화방열식 전체환기 설비가 타방식과 비교하여 작동방식이 단순하며, 에너지 소비가 적은 경제적인 냉각설비이며, 급기의 습도 제어기능만 부가되면 매우 효율적인 환기 - 냉각기능을 동시에 수행할 수 있는 설비임을 확인하였다.