Purpose : A new inhomogeneity correction method based on two-point Dixon sequence is proposed to obtain water and fat images at 0.35T, low field magnetic resonance imaging (MRI) system. Materials and Methods : Joint phase-magnitude density function (JPMF) is obtained from the in-phase and out-of-phase images by the two-point Dixon method. The range of the water signal is adjusted from the JPMF, and 3D inhomogeneity map is obtained from the phase of corresponding water volume. The 3D inhomogeneity map is used to correct the inhomogeneity field iteratively. Results : The proposed water-fat imaging method was successfully applied to various organs. The proposed 3D inhomogeneity correction algorithm provides good performances in overall multi-slice images. Conclusion : The proposed water-fat separation method using JPMF is robust to field inhomogeneity. Three dimensional inhomogeneity map and the iterative inhomogeneity correction algorithm improve water and fat imaging substantially.
Spin echo gradient moment nulling pulse sequences were designed and implemented on a clinical magnetic resonance imaging system. A new technique was introduced for flow compensation that minimized echo time and effectively suppresses unwanted echoes on the slice selection gradient axis in spin echo sequences. A unified gradient shape was used in all orders of flow compensation up to the third order. A dual-purpose gradient was applied for flow compensation and to reduce unwanted artifacts. The sequences were used to generate images of phantoms and/or human brains. This technique was especially good at reducing eddy currents and artifacts related to imperfection of the refocusing pulse. The developed sequences were found to have shorter echo times and better flow compensation in through-plane flow than those of the previous models that were used by other investigators.
Computed tomography (CT) has been increasing in frequency and indications for use in clinical diagnosis and treatment decisions. Multidetector CT has the advantage of shortening the inspection time and obtaining a high resolution image compared to a single detector CT, but has been pointed out the disadvantage of increasing the radiation exposure. In addition, when the low tube voltage is used to reduce the exposure dose in the CT, noise increases relatively. In the existing method, the method of finding the optimal image quality using the method of adjusting the parameters of the image reconstruction method is not a fundamental measure. In this study, we applied a double-tree complex wavelet algorithm and analyzed the results to maintain the normal signal and remove only noise. Experimental results show that the noise is reduced from 8.53 to 4.51 when using a complex oriented 2D method with 100kVp and 0.5sec rotation time. Through this study, it was possible to remove the noise and reduce the patient dose by using the optimal noise reduction algorithm. The results of this study can be used to reduce the exposure of patients due to the low dose of CT.
A research for middleware of WSN can provide sensor applications with avoiding tight coupling of hardware, ease of development, and abstract data access. However, previous works have some limitations which should install their own middleware onto the all sensor nodes resulting in computational and communication overhead. In order to address it, we proposed a virtual sensor overlay network, called TinyONet-Lite which introduced virtual sensors to model a virtual counterpart of physical sensors. These virtual sensors dynamically grouped into an overlay network, Slice, which provides middleware services. We implemented TinyONet-Lite on mote class hardware with TinyOS. In accordance with experiments and comparison with existing researches, TinyONet-Lite was proved to show advantages of extensibility, dynamic service composition and reducing overhead.
This paper introduces effective noise removal method for medical ultrasound volume data. Ultrasound volume data need to be filtered because it has a lot of noise. Conventional 2d filtering methods ignore information of adjacent layers and conventional 3d filtering methods are slow or have simple filter that are not efficient for removing noise and also don't equally operate filtering because that don't take into account ultrasound' sampling character. To solve this problem, we introduce method that fast perform in parallel bilateral filtering that is known as good for noise removal and adjust proportionally window size depending on that's position. Experiments compare noise removal and loss of original data among average filtered or biliteral filtered or adaptive biliteral filtered ultrasound volume rendering images. In this way, we can more efficiently and correctly remove noise of ultrasound volume data.
H.264/AVC compresses video data by applying DCT transform, quantization and entropy coding processes to the residual signal obtained by inter/intra prediction. This paper proposes a method enhancing an existing DC offset adjustment technology which uses information of neighboring blocks to reduce residual information for improving coding efficiency. DC offset information is not sent over bitstreams, but calculated in the same way both in the decoder and in the encoder. Experimental results show that the proposed method enhances coding efficiency by 0.25% in average BD-Rate compared to H.264/AVC and gives better or worse coding efficiency compared to the existing DC offset method depending on video sequences with coding efficiency degradation by 0.09% in average BD-Rate. This experimental results also show that further coding efficiency improvement is possible by applying the proposed method adaptively to slice or macroblock coding units.
Lee, Jae Choon;Kim, Ae Ran;Ji, Young Hoon;Kwon, Soo-Il
Progress in Medical Physics
/
v.27
no.2
/
pp.72-78
/
2016
A CCD camera and an LED light source were combined to fabricate a compact optical CT scanner for the therapeutic radiation dose evaluation of a polymer gel dosimeter. After the collimated beam emitted by the LED passed through aquarium, gel phantom, and telecentric lens, an image was collected by the CCD camera and reconstructed using MATLAB. By using a stepping motor and LabVIEW, the gel dosimeter was rotated at every $0.72^{\circ}$, and the time for collecting 500 slice images per a revolution was within 20 min. At a spatial frequency of 4.5 lp/mm of the optical CT scanner, the modulation transfer function value was 72%. The linear correlation coefficient of the optical CT scanner for the polymer gel dosimeter was 0.987.
Transactions of the Korean Society of Mechanical Engineers A
/
v.35
no.12
/
pp.1635-1640
/
2011
The objective of this study is to design of a cooling system of the over-molding mold for a socket component of an automobile wiper by performing numerical analyses. Hot spots in which the temperature distributions are higher than those of other region, were estimated by an initial over-molding analysis for the initial design of the mold. On the basis of the initial over-molding analysis, two types of cooling system designs with a linear cooling channel and a volumetric heat sink, were considered to improve the cooling characteristics of hot spots. To obtain an appropriate cooling system design, the effects of the diameter and the position of the linear cooling channels on the cooling characteristics and the product qualities were quantitatively examined. In addition, the effects of the design of the volumetric heat sink on the cooling characteristics and deformation distributions in the molded product were investigated. The results of the over-molding analysis of the two types of cooling systems showed that the multi-sliced over-molding mold with a volumetric heat sink can improve both the product quality and the cooling characteristics of the mold.
The dependence of CT scanning parameters on the CT number to physical density conversion from the CT image of CT and CBCT electron density phantom acquired by the CT scanner using in radiotherapy were analyzed by experiment. The CT numbers were independent of the tube current product exposure time, slice thickness, filter of image reconstruction, field of view and volume of phantom. But the CT numbers were dependent on the tube voltage and cross section of phantom. As a result, for physical density range above 0, the maximum CT number difference observed at the tube voltage between 90 and 120 kVp was 27%, and the maximum CT number difference observed between CT body and head electron density phantom was 15%.
고압처리로 멸균된(high-pressure- sterilized) 저산성 식품은 아직 본격적으로 시장에 나오지는 않고 있다. 그러나 고압처리로 살균시켜(high-pressure-pasteurized) 제품의 부가가치를 높인 상품들은 일부 시판되고 있다. 미국시장에는 구아카몰(guacamole),굴 등이 있고, 일본과 유럽에는 잼, 젤리, 생선제품, 육제품, 슬라이스 햄, 샐러드 드레싱, 쌀떡, 주스, 요구르트 등이 판매되고 있다. 기술이 발전되어 처리비용이 떨어짐에따라 우유나 오렌지 주스 같은 저부가가치의 제품(high-volume commodity products)에도 고압처리 기술이 적용되는 예를 보게 될 것이다.미국 FDA의 "열처리된 저산성식품은 용접밀봉된 용기(캔, hermetically sealed container)에 포장되어야 한다." 는 규정(Title 21, Part 113 of the Code Federal Regulations)은 고압처리 식품을 염두에 두고 만들어진 규정은 아니지만, 저산성식품의 고압처리 공정(high-pressure processing)은 강력한 살균력을 제공하고 있다. 따라서 위의 FDA 규정(21 CFR 113)의 모든 조항은 고압처리 저산성 식품이 상업적인 생산에 들어가기 전에 시행되어야만 하는 것이다. 그 규정의 주요 조항중의 하나는 고압처리 공정에 대한 전문적인 지식을 가진 전문가나 위원회 등에 의하여 세부적인 고압처리공정 절차를 확립하는 것이다. 공정의 전문가들은 안전성을 증명하기 위해서 적합한 과학적인 방법을 사용하여 고압처리 공정을 확립해야만 한다. 저산성 식품에 대한 고압처리 공정은 주의깊게 설정된 공정조건하에서 재현성 있게 안전한 식품을 생산할 수 있어야 한다. 살균에 대한 안전성과 재현성이 입증되면 고압에 의한 살균처리공정 설계는 일반적인 대량생산 공정으로 활용될 수 있게 된다. PP(고압처리공정)의 유효성이 보다 확실하게 입증되고 널리 활용되려면, 공정의 살균력과 일관성(uniformity)을 증명하는 미생물적, 물리적, 화학적, 공학적인 여러 분야가 통합된 검증방법이 필요하다. 전통적인 열처리 공정은 스팀열의 가열시간으로 설명이 충분하다. 물론 HPP살균에서도 시간과 온도는 주요 변수이지만, 압력에 의한 미생물살균도 고려되어야만 한다. 또한 점도, 밀도, 구성성분, pH, 수분활성도 같은 해당제품의 특성도 제품의 고압처리 살균공정, 특히 미생물의 사멸에 영향을 미칠 수도 있다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.