• Title/Summary/Keyword: 스핀변조

Search Result 8, Processing Time 0.04 seconds

A Dual-channel Receiver for Spintronics Oscillator Array (Spintronics 발진기 어레이에 적합한 듀얼채널 수신기)

  • Oh, Inn-Yeal;Park, Seung-Young;Park, Chul-Soon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.4
    • /
    • pp.66-75
    • /
    • 2013
  • The spin modulation is proposed with modulating frequency and amplitude simultaeously, and realized with the array sturcture easily located due to the nanometer size of the spintronics oscillator. In this paper, the dual-channel receiver is deisgned for detecting the spin modulated signal. Resultly, we confirmed the dual-channel recevier well detected the data sent through the spintronics oscillator array, and processed up to 200 kbps on each channel. Distance is limited up to 1 cm due to the low level signal under -60 dBm. The realized dual-channel receiver has the size of $56{\times}33mm^2$.

$^{1}H$ Nuclear Magnetic Relaxation in Impure $CuF_{2}.2H_{2}O$ (비자성 불순물을 갖는 $CuF_{2}.2H_{2}O$의 수소 핵자기완화 연구)

  • C. H. Lee;C. E. Lee;S. J. Noh
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.854-857
    • /
    • 1995
  • We have studied the temperature dependence of the $^{1}H$ NMR spin-lattice relaxation for the impure $CuF_{2}.2H_{2}O$ over a temperature range from 77 K to room temperature. We find that the remperature dependence of the $^{1}H$ spin-lattice relaxation is dominated by the eletron spin-flip and the Raman process of eletron spin-lattice relaxation. The electron spin-flip exchange energy was calculated to be $1.8(\pm0.04)$ K.

  • PDF

Study on NMR Measurment of Flowing Water by a Separated Detector (분리형 감지기를 이용한 흐르는 물의 핵자기공명 측정연구)

  • ;;;;V. Ya. Shifrin
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.3
    • /
    • pp.165-170
    • /
    • 1995
  • NMR measurement has been studied for protons in pre-polarized flowing water by a separated detector working at high field far away from the measured field region where the transition of protons is occurred by the pertur-bation of RF energy. The conditions for NMR signal were optimized on the amplitude and frequency of modulation field, the RF field of detector, water speed, and RF field at the measured field region. The NMR signal with the full width of 320 nT at the half maximum in Lorentzian curve and with signal to noise ratio of 10.5 was measured in the range from a few ${\mu}T$ to mT, and its shape and amplitude were independent of the measured field intensity and its uniformity.

  • PDF

A Study on the Magnetic and Magneto-Optical Properties of Tb/Co Composition Modulated Multilayer Films (Tb/Co 조성변조 다층박막의 자기 및 광자기적 성질에 관한 연구)

  • 홍석지;김상록;이성래
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.3
    • /
    • pp.158-164
    • /
    • 1996
  • The magnetic and magneto-optical properties of the Tb/Co multilayers as a function of the layer thickness and the ratio of Tb/Co thicknesses were studied. When the thickness of Tb layer was $12{\AA}$, the maximum perpendicular anisotropy energy and the maximum thickness ratio which displays the perpendicular anisotropy were obtained. This result indicated that the Tb-Tb and Co-Co pairs as well as the Tb-Co pairs contribute to the perpendicular anisotropy. The Kerr rotation angle, $({\theta}_k)$ was proportional to the perpendicular anisotropy energy and was inversely proportional to the average spin dispersion angle, $(\alpha)$. The maximum $({\theta}_k)$ of $0.28^{\circ}$ was obtained in the film of $12{\AA}$ Tb and the thickness ratio of 1.55. The abnormal hysteresis loops were appeared during the aging treatment because the coercivity difference between the Co layer and the Tb layer was increased by the preferential oxidation of Tb.

  • PDF

Comparison Study of the Modulation Transfer Function of a Prototype a-Se based Flat Panel Detector with Conventional Speed Class 400 Film/screen System (비정질 셀레늄을 이용한 직접방식의 디지털 방사선 검출기와 X-ray film과의 MTF측정을 통한 영상 질(quality) 비교평가에 관한 연구)

  • Park, Jang-Yong;Park, Ji-Koon;Kang, Sang-Sik;Moon, Chi-Woong;Lee, Hyung-Won;Nam, Sang-Hee
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.3
    • /
    • pp.163-171
    • /
    • 2003
  • To evaluate the performance of the digital radiography(DR) system developed in our group, the modulation transfer function(MTF) was measured and compared with that of an analog X- ray detector, film/screen system. The DR system has an amorphous selenium(a-Se) layer vacuum-evaporated on a TFT flat panel detector. The speed class 400 film/screen (Fuji) system has been being used in the clinical field as analog X-ray detectors. Both the square wave and slit method were used to evaluate their MTF. The square method was applied to both film/screen and the DR system. The slit method, however, was applied to only DR system. The full-width half maximum resolution of film/screen was 357${\mu}{\textrm}{m}$(1.4 lp/mm at 50% spatial frequency), and the resolution of DR was limited to 200${\mu}{\textrm}{m}$(2.5 lp/mm at 30%). These results indicate the measured resolution limitations approximate to the pixel pitch, 139 ${\mu}{\textrm}{m}$ of TFT. The MTF of DR is higher than that of film/screen by the factor of 1.785. It is proved that our a-Se based DR system has potential usefulness in the clinical field.

Refractive index change of nonlinear polymer thin films induced by corona poling and quantitative evaluation of poling effect (코로나 극성배향이 비선형 고분자박막의 복소굴절율에 미치는 영향 및 배향효과의 정량화)

  • 길현옥;김상준;방현용;김상열
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.3
    • /
    • pp.181-187
    • /
    • 1999
  • We prepared the side-chain type nonlinear optical NPP(N-(6-nitrophenyl)-(L)-prolinol) polymer films by spin coating method. Ellipsometric spectra were in situ collected by using spectroscopic phase modulated ellipsometer while the NPP polymer films were being corona poled at the temperature above glass transition. We calculated film thickness and the refractive index dispersion by modeling the spectro-ellipsometry data in transparent region. We also calculated the refractive index and the extinction coefficient of the polymer films by numerically inverting the spectro-ellipsometry data in absorbing region, while the previously determined film thickness was used. The independently determined extinction coefficient spectra from the analysis of transmission spectra were compared with those by spectro-ellipsometry and they showed an excellent agreement with each other. From the analysis of the complex refractive index change of the NPP polymer thin films induced by the corona poling, we could determine the vertical complex refractive index and the horizontal complex refractive index separately. Using the volume fraction of the vertical component f⊥, the degree of poling of poled NPP polymer films was quantitatively addressed. It is suggested that the present method can be used to quantitatively address the degree of poling in an absolute manner and to depth profile the poled fraction of thick polymer films. It will be useful to understand the structural change of polymer films and hence the poling mechanism during the poling process.

  • PDF

Cell-cultivable ultrasonic transducer integrated on glass-coverslip (세포 배양 가능한 커버슬립형 초음파 변환자)

  • Keunhyung Lee;Jinhyoung Park
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.412-421
    • /
    • 2023
  • Ultrasound brain stimulation is spot-lighted by its capability of inducing brain cell activation in a localized deep brain region and ultimately treating impaired brain function while the efficiency and directivity of neural modulation are highly dependent on types of stimulus waveforms. Therefore, to optimize the types of stimulation parameters, we propose a cell-cultivable ultrasonic transducer having a series stack of a spin-coated polymer piezoelectric element (Poly-vinylidene fluoride-trifluorethylene, PVDF-TrFE) and a parylene insulating layer enhancing output acoustic pressure on a glass-coverslip which is commonly used in culturing cells. Due to the uniformity and high accuracy of stimulus waveform, tens of neuronal cell responses located on the transducer surface can be recorded simultaneously with fluorescence microscopy. By averaging the cell response traces from tens of cells, small changes to the low intensity ultrasound stimulations can be identified. In addition, the reduction of stimulus distortions made by standing wave generated from reflections between the transducers and other strong reflectors can be achieved by placing acoustic absorbers. Through the proposed ultrasound transducer, we could successfully observe the calcium responses induced by low-intensity ultrasound stimulation of 6 MHz, 0.2 MPa in astrocytes cultured on the transducer surface.