An Investigation on the Thermal Characteristics of Heat-Responsive Element of Sprinkler Head (스프링클러헤드 감열부의 열적 특성에 관한 연구)

  • You, Woo-Jun;Moon, Hyo-Jun;Youm, Moon-Cheon;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.79-84
    • /
    • 2012
  • In this study thermal characteristics of heat-responsive element considering conduction, convection and rate of change of element using Response Time Index (RTI) applied to sensitivity test of sprinkler head at home and aborad are theoretically investigated. Analytic solution of temperature distributions with radial direction and time is obtained form energy transport equations, non-homogeneous 2th order partial differential equation, applying to constant wall temperature and symmetric condition in order to analyze thermal characteristics of heat-responsive element for circular cylindrical geometry. Base on the results, the analytic method of this study is fundamental data to practical use for sensitivity test of sprinkler head and design of heat-responsive element.

A Study about Introductory Plan of Automatic Wet Pipe Sprinkler System to Hydraulically Designed System (습식 스프링클러설비의 수리계산방식 도입방안에 관한 연구)

  • Park, Bong-Rae;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.69-77
    • /
    • 2007
  • Our country automatic wet pipe sprinkler system of hydraulically designed system has not deviated from the pipe regulation process, therefore we face limitations when using an independent method to hydraulically designed system. Therefore. after reviewing a developed country's methods using the drainage-density concept, we found it necessary for our country to introduce the drainage-density concept. Currently, under the National Fire Safety Codes(NFSC), this does not solve the problem and the limitation of hydraulically designed system because different problems arise depending on where the head was installed. To make improvements, first, such as the developed country, overcome the difference by introducing the drainage-density concept to determine the amount of drainage. Second, by using diverse head caliber and decreasing the limits on the amounts of distribution, we can expect a leveling off of the drainage density. Third, using the increase of hydraulically designed system through the application of the rule to hydraulically designed system, finally, development to performance based fire protection design.

A study on the Comparison of High-rise building Egress Safety Rule in Countries for improvement of High-rise evacuation safety design criteria (초고층 피난안전설계 기준 개선을 위한 국내외 피난관계법령 비교에 관한 연구)

  • Hwang, EunKyung;Park, SuRoh
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.429-438
    • /
    • 2013
  • In this study, compare and analyze for high-rise evacuation safety design criteria improvement about internal high-rise building egress safety rule. To the result, high-rise evacuation safety design criteria improvement data can be summarized as follows. First, should compute the evacuation capacity about the number of persons and when more than 2 exits are requested, over 50% of evacuation capacity must be satisfied even approaching to 1 exit is unable. Second, 2 ways of evacuation can be made smoothly by the stair or exit separation-distance standard regulation. Third, regulate the length limitation of dead-end corridor or passageway and it should give grades in limitation of whether the spring-cooler has been installed. Fourth, must secure the evacuation way and do the evacuee guidance when it's safety area and elevator or stair. Also needs to provide extra safety area to secure horizontal direction Escape Safety except fire escaping floor.

A Proposal on the Pipe Schedule Sprinkler System of NFSC 103 (NFSC 103 스프링클러설비의 배관스케줄방식에 대한 제안)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.40-47
    • /
    • 2014
  • Design by means of the pipe schedule sprinkler system of NFSC 103 results in insufficient pressure and flow rate about 50% sprinklers of operating area. In order to solve the lack of pressure and flow rate, This paper compare and analyzed NFSC 103, National Fire Safety Code of Sprinkler System, with NFPA 13, Standard for the Installation of Sprinkler Systems, and suggested an alternative proposal. Changing the flow rate of each sprinkler from existing 80 L/min to 120 L/min, All of the operating sprinklers are fulfilled the minimum demands on 80 L/min and 1 bar. It is easy for everyone to design of the pipe schedule sprinkler system and it is optimum method that all sprinklers in design area are satisfied with minimum criteria.

Simulation of Fire in Large Cleanrooms (대규모 클린룸 화재의 시뮬레이션)

  • Park, Woe-Chul
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.29-33
    • /
    • 2014
  • Cleanroom fires were simulated by using Fire Dynamics Simulator. A grid size of $0.5{\times}0.5{\times}0.2m^3$ was selected following review of grid sizes. Fires in three large cleanrooms were investigated to confirm safety by applying the requirements on temperature, visibility, and carbon monoxide concentration in performance based design. The worst situation without sprinkler system and air flow of 0.1 m/s downward in the cleamrooms was considered. It was confirmed that all the three cleanrooms were safe in case without sprinklers since the temperature was below the safety requirement. Decrease in visibility and carbon monoxide concentration due to the fires were negligible.

A Study on Hydraulic Calculation Procedure of Fire Sprinkler System Design (스프링클러설비 설계의 수리계산 절차에 대한 연구)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.24-32
    • /
    • 2018
  • There are two kinds of method on hydraulic calculation of fire sprinkler system design. The one is using the computational program and the other is designer calculate system for oneself. In case of using the computational program, putting the input data in, the program calculate the friction loss, water flow, total height and so forth. If program user or designer doesn't know the basic idea and procedure of hydraulic calculation. Then, the outputs are different from each other. This paper suggests the hydraulic calculation procedure in design area as follow. Equivalent lengths of tees on the branch are selected base on the same pipe diameter which the tees are established, although the diameter of tee outlet is different. Even though there is a different friction loss of head from the other head, the pressure from the hydraulic end is bigger than a head loss, discharge flow is calculated by pressure from the hydraulic end.

Performance-based Fire Protection Design of Domestic Super High-rise Buildings - Evaluation by ASET and RSET -

  • Roh, Hyeong-Ki
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.2
    • /
    • pp.9-13
    • /
    • 2011
  • The Performance-based fire protection design required to construct super high-rise building is the active measure for the evaluation of fire risks and the establishment of fire protection systems on the basis of engineering analysis, which is more efficient and proper than existing prescriptive-based design. This study applied time-line analysis of RSET is required safe egress time and ASET is available safe egress time with the fire and evacuation simulation to analyze. The result of this study showed the sprinkler system increased ASET and fire detection and alarm system reduced RSET efficiently. Reduced evacuation time influences to secure the life safety. Also it is essential to maintain the fire suppression system and fire detection & alarm system properly. Database of fire movement and evacuation action program are useful for the performance-based design.

Proposal for Evacuee Guidance of Cloud-based Elevator System in Emergency Situation (클라우드 기반 비상탈출 시 피난유도 승강기시스템 제안)

  • Choi, Jun-Ho;Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.1
    • /
    • pp.25-28
    • /
    • 2015
  • Lifts are used as an essential means of transportation within the building in an emergency situation, when used as a means of escape, so expect a lot of research has been conducted high effect. Number of stories in the Seoul-rise building guidelines underground 7th floor, 53 ground floor, floor area $6,800m^2$, floor area $127,050m^2$, use is cultural and convention facilities and sales facilities, business facilities and accommodation (hotel), the construction of public housing (apartments) hagieneun not efficient to install elevators for evacuation mothada was determined separately in designing the lift is designed according to the standards of passenger lifts installed under a judgment as to use for evacuation. However, this does not include detailed design guidelines so far.[1] We propose the Evacuee Guidance of Elevator System that can be used as entering air equipment, sprinkler and smart phone evacuation system.

A study on the standard of effective fire facilities for the Atrium (아트리움 공간의 효과적인 방화설비 기준연구)

  • Choi, Don-Mook;Kim, Jae-Woon;Min, Se-Hong
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.6 no.1
    • /
    • pp.49-66
    • /
    • 2005
  • The purpose of this study is to present reference data to be considered in designing fur the fire safety of atrium buildings. This study deals with the characteristics of atrium buildings in the fire safety aspect, analysis of fire examples and foreign fire codes of atrium space. And con-crete factors to be consigning fur the fire facilities of atrium buildings are presented. Recently many atrium spaces have been built in Korea. They provide new experience of space with resident and pedestrians. However, because of the lack of knowledge in design principle and disaster prevention, large loss of lives is expected in an emergency situation. cion. Therefore safety ensuring from the case is urgently needed. The following is the summary on the standard of effective fire facilities for the atrium. 1. The smoke control. inside atrium must use the machine ventilation in the atrium. 2. It is desirable to divide the section between atrium and nearby living room by anti-smoke screen in order to prevent damage by smoke when fire break out. 3. It is desirable to instill an excellent fire detector like infrared light detector as a replacement of old one. 4. It is desirable to transfer from closed operating sprinkler to fire-cycle sprinkler equipment or ablative sprinkler when the height is lower than 20m.

  • PDF

Classification of Fire Causes in Warehouses Using the TRIZ Technique and Analysis of Preventive Measures Accordingto 4M (TRIZ기법에 의한 물류창고의 화재원인 및 4M에 따른 예방대책 분석)

  • Han, Sang-Hun;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.3
    • /
    • pp.401-412
    • /
    • 2020
  • This study analyzed the causes of warehouse fires using a creative problem-solving technique called TRIZ. It identified preventive measures by applying 4M. The results are as follows. First, this study examined the inconsistency among the causes of warehouse fires using TRIZ. Second, it analyzed human factors and fire prevention measures in warehouses such as safety standards for managers, and methods for the promotion of safety consciousness among workers, and for the reinforcement of construction technology for sandwich panel workers. Third, it identified the mechanical and facility factors and fire prevention measures in warehouses such as safety facilities, the expanded installation of safety devices, the adoption and development of fire suppression equipment, and the deployment of methods to improve the fire resistance of sandwich panels. Fourth, it presented working and environmental factors and fire prevention measures in warehouses such as the tightening of safety precautions and the supervision of working methods, and setting fire partitions both in loading places and based on performance-based design. Finally, it proposed managerial factors and fire prevention measures in warehouses such as specific targeting for firefighting with low fire hazards, reviewing the material quality regulations of non-combustible or higher for sandwich panels in the specific target of firefighting that cannot apply fire safety standards, installing sprinklers in cold storage, and mandating the installation of automated facilities with retroactive application regardless of the floor area in the warehouse with a sandwich panel structure.