• Title/Summary/Keyword: 스프링클러설비

Search Result 111, Processing Time 0.022 seconds

Development of Performance Index for Ubiquitous Building Fire Safety System - Focused on Sprinkler System - (유비쿼터스 건물 화재안전시스템을 위한 성능지수 개발 - 스프링클러 시스템을 중심으로 -)

  • Kim, Jong-Hoon;Roh, Sam-Kew
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.23-30
    • /
    • 2009
  • For managing fire safety system in building by ubiquitous management system, the index system to express the performance level of fire protection system is demanded. If some component formed fire protection system such as sprinkler water supply system is breakdown, that will fall down the performance of fire protection capacity. Consequently, it will affects the level of fire safety of building management and energy response. Consequently, Building fire protection system could give performance level of fire protection condition and the level of fire safety in building. It will also contribute to the development of wide area fire safety management. This development of index system has been developed as a part of the development project of Ubiquitous building fire management system.

Evaluation on Fire Spread Speed of Standard Rack in Korea for Performance based Fire Extinguishing System (성능위주 소화설비 적용을 위한 표준랙크의 화재확산속도 평가)

  • Cho, Gyu-Hwan;Yeo, In-Hwan
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.84-91
    • /
    • 2016
  • In case of fire, vertically and intensively loaded rack warehouses are faced with a severe status due to the rapid increase in fires. In this regard, there have been trials to prevent fires from spreading by applying fire extinguishing systems, such as ESFR and In-Rack Sprinklers, vertical and horizontal barriers, etc.; however, it is difficult to calculate and design proper fire extinguishing systems caused by various composition conditions, such as the size and loading density of the rack, types of loading commodities, etc. Therefore, in this study, a standard rack was manufactured, incorporating a rack warehouse in Korea by site investigations, surveys, etc. In addition, a full scale fire test was executed to check the fire characteristics depending on the conditions of the ignition points. As a result, the extracted fire spread speed is expected to be utilized as a reference for performance comparisons of the fire extinguishing systems to be developed and applied in the future.

A Study on the Application of Hydraulic Calculations considering the Corrosion Coefficient of Steel Piping for Fire Protection (소방용 강관배관 부식계수를 고려한 수리계산 적용방안에 관한 연구)

  • Mun, Chul-Hwan;Kang, Ho-Jung;Choi, Jae-Wook
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.69-77
    • /
    • 2020
  • With the recent enlargement and complication of buildings, damage caused by the incidents of fires breaking out are escalating. Consequently, the use of sprinkler facilities is increasing among water-based fire extinguishing systems. Piping materials used in fire prevention systems include carbon steel (for general or pressure pipeline), CPVC, copper, and stainless-steel. Among these, the steel and CPVC pipes, which are commonly employed in fire prevention, were considered for testing the reliability of the water-based systems. This analysis was performed using the PIPENET software to perform hydraulic calculations in order to examine the flow and pressure at the terminal head when the corrosion coefficient was applied; this coefficient was applied considering the aging of pipes. Assuming a uniform pipe diameter in the steel pipes, the rated flow in the pump installed on the first floor of the basement was reduced by over 10% after 20 years had passed (C value of 90); moreover, the reduction in pressure and flow at its terminal head exceeded 30% and 16.5%, respectively. The results indicate that it is difficult to ensure the reliability of these fire prevention facilities. Furthermore, according to our estimation, considering 30 years had passed (C value of 80), the rated flow of the pump was reduced by over 15%, and the corresponding reduction in pressure and flow at its terminal head exceeded 42% and 24%, respectively.

A Study on a Method for Fire Suppression in a Central Area inside the Roof of a Wooden Cultural Property using a Gas Extinguishing Apparatus (가스소화설비를 이용한 목조 문화재 적심부 화재진압 방법에 관한 연구)

  • Kim, Hyunsung;Kim, Byung Sean;Cho, Woncheol;Lim, Yun Mook
    • Journal of Korean Society of societal Security
    • /
    • v.3 no.2
    • /
    • pp.65-71
    • /
    • 2010
  • This study was conducted to provide a method for fire suppression in a central area inside the roof of a wooden cultural property using a gas extinguishing apparatus, which is used as one of fire suppression methods with view to preventing valuable wooden properties inherited from ancestors from being destructed by fire. For a wooden property, it is very difficult to suppress fire when combustion spreads to a central area inside its roof, so it is impossible to put out a fire without destructing it. Such a fire fighting apparatus as a sprinkler, etc., installed in modern structures, is very effective, but the possibility of damaging a cultural property is highly probable after installment and operation, which leads to its low adaptability to a wooden property. Thus, the necessity of developing a fire suppress ion apparatus was raised to minimize the said problem and to obtain the desired results, and the need of making a plan on the installment was also raised based on the results of a test whose validity was proven. The central area inside a roof is a traditional - architectural style which is found in Korean wooden structures only, so it is impossible to discover similar cases in foreign countries. For this reason, this study was conducted to verify the effectiveness by developing a fixed fire suppression apparatus designed considering the speed and effectiveness in fire suppression. This study was sequentially carried out in the following steps. First, a frame for this study was made and the specific plan on a fire suppression method was established. Then, a fire suppression apparatus was installed. In the first step, the effectiveness for fire suppression was tested by installing valve open - punched - main water pores, and in the second step, the same effectiveness was tested by valve opened - punched - injection ports. For a wooden property similar to "Sungnyemun"(Gate of Exalted Ceremonies), its central area of the roof decides whether the fire suppression is successful or not, so the opinions on how to put out a fire were presented in this study, and thus the objective data to establish a method on fire suppression in a wooden structure(cultural property) was secured. Lastly, a scientific verification in the effectiveness for fire suppression measures was presented by installing a gas - fixed fire suppression apparatus.

  • PDF

Improvement of Citadel Structure on Board Ship Using FDS (화재 시뮬레이션을 이용한 선원대피처의 구조 개선에 관한 연구)

  • Kim, Won Ouk;Kim, Jong Su;Park, Woe Chul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.306-311
    • /
    • 2015
  • Recently, vessel hijacking by pirates has been a big issue around the world. In case of the hostages of M/V "SAMHO Jewelry" on January 20, 2011, the Korean Navy has rescued 21 seafarers by first naval operation with somalia pirates since establishment of the Navy. Also, in case of the "HANJIN Tianjin", all crews evacuated to the Citadel promptly when being attacking by pirates and were safely rescued by the navy. By the accident, Necessity of Citadel for seafarer on board ship came to the fore against pirates. Taking in account increasing pirates accident at sea, many research relating to pirates has been implementing with a view to responding to them so far. By amending the ship facility regulation in the domestic law on Jan. 2011, the installment of Citadel on board ship became mandatory for ocean going vessel serving pirates area. Hence, this paper provides new model of Citadel structure based on an Fire Dynamic simulation in order to improve personal safety in case of vessel hijacking.

Performance-based Fire Protection Design of Domestic Super High-rise Buildings - Evaluation by ASET and RSET -

  • Roh, Hyeong-Ki
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.2
    • /
    • pp.9-13
    • /
    • 2011
  • The Performance-based fire protection design required to construct super high-rise building is the active measure for the evaluation of fire risks and the establishment of fire protection systems on the basis of engineering analysis, which is more efficient and proper than existing prescriptive-based design. This study applied time-line analysis of RSET is required safe egress time and ASET is available safe egress time with the fire and evacuation simulation to analyze. The result of this study showed the sprinkler system increased ASET and fire detection and alarm system reduced RSET efficiently. Reduced evacuation time influences to secure the life safety. Also it is essential to maintain the fire suppression system and fire detection & alarm system properly. Database of fire movement and evacuation action program are useful for the performance-based design.

Extinguishing Charactristics of Water Mist by Discharge Properties (방사특성 변화에 따른 미세물분무의 소화특성)

  • 이경덕;신창섭
    • Fire Science and Engineering
    • /
    • v.15 no.4
    • /
    • pp.41-48
    • /
    • 2001
  • Halogen-based fire suppressing agents have been the most effective fire suppressants and widely used for flammable liquid and electric fire. However they have environmental problems causing stratospheric ozone depletion and globe warming. As a substitution of halon, fire suppression system using fine water mist is one of an effective fire suppressant. Suffocating and cooling effects of water mist are increased by the evaporation characteristics because it has droplet size less than 1,000 $\mu{m}$ and very large surface area. In this study, the extinguishing characteristics of fire was measured with changing of water mist droplet size, flow density; discharge pressure, and fire size. As a result, the extinguishing time of pool fire was shortened with the increase of flow density and in case of low flow density less than 0.5$\pm$0.05 ml/$\textrm{cm}^2$ . min, the extinguishing time was shortened with the increase of droplet size. The cycling discharge was effective for $\eta$-heptane pool fire, and total amount of water mist required to extinguish fire was reduced to a quarter compare with continuous discharge.

  • PDF

A Study on the Recording Technology of Fire Propagation Prevention Wall Using Horticultural Plants (원예식물을 식재한 화재확산 방지용 벽면녹화 기술연구)

  • Moon, Jong-Wook;Lim, Seo-Hyung
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.2
    • /
    • pp.107-114
    • /
    • 2018
  • Purpose : This study is to develop walls using wall recording technology applied on roofs to prevent fire spread in traditional markets. Method : The spray head installed on the developed wall was designed so that the fire does not spread to adjacent buildings after being used for plants. In addition, a spray head was attached to the upper section and some sections for the growth of plants planted on the wall to prevent the spread of fire. Results : These technologies suggested the development of walls that can be installed at the upper level of buildings, such as traditional markets, and separate isolation facilities were not necessary because they are integrated with structures and sprinklers. In addition, sprinklers can perform both the plant spray and fire spread prevention functions. It is believed that this is the only alternative technology proposed in Korea to prevent the spread of fire. Conclusion : In this study, the wall design, designed directly to derive the quantitative performance of the fire spread reduction effect, demonstrated the fire suppression method of the wall system, the durability of the wall itself, and the flame retardability performance.

A study on the standard of effective fire facilities for the Atrium (아트리움 공간의 효과적인 방화설비 기준연구)

  • Choi, Don-Mook;Kim, Jae-Woon;Min, Se-Hong
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.6 no.1
    • /
    • pp.49-66
    • /
    • 2005
  • The purpose of this study is to present reference data to be considered in designing fur the fire safety of atrium buildings. This study deals with the characteristics of atrium buildings in the fire safety aspect, analysis of fire examples and foreign fire codes of atrium space. And con-crete factors to be consigning fur the fire facilities of atrium buildings are presented. Recently many atrium spaces have been built in Korea. They provide new experience of space with resident and pedestrians. However, because of the lack of knowledge in design principle and disaster prevention, large loss of lives is expected in an emergency situation. cion. Therefore safety ensuring from the case is urgently needed. The following is the summary on the standard of effective fire facilities for the atrium. 1. The smoke control. inside atrium must use the machine ventilation in the atrium. 2. It is desirable to divide the section between atrium and nearby living room by anti-smoke screen in order to prevent damage by smoke when fire break out. 3. It is desirable to instill an excellent fire detector like infrared light detector as a replacement of old one. 4. It is desirable to transfer from closed operating sprinkler to fire-cycle sprinkler equipment or ablative sprinkler when the height is lower than 20m.

  • PDF

Project of Improving Good Agriculture Practice and Income by Intergrated Agricultural Farming (미얀마 우수농산물 재배기술 전수사업)

  • Lee, Young-Cheul;Choi, Dong-Yong
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.16 no.1
    • /
    • pp.193-206
    • /
    • 2014
  • The objectives of the project are to increase farmers' income through GAP and to reduce the loss of agricultural produce, for which the Korean partner takes a role of transferring needed technologies to the project site. To accomplish the project plan, it is set to implement the project with six components: construction of buildings, installation of agricultural facilities, establishment of demonstration farms, dispatching experts, conducting training program in Korea and provision of equipments. The Project Management Committee and the Project Implementation Team are consisted of Korean experts and senior officials from Department of Agriculture, Myanmar that managed the project systematically to ensure the success of the project. The process of the project are; the ceremony of laying the foundation and commencing the construction of training center in April, 2012. The Ribbon Cutting Ceremony for the completion of GAP Training Center was successfully held under PMC (MOAI, GAPI/ARDC) arrangement in SAl, Naypyitaw on June 17, 2012. The Chairman of GAPI, Dr. Sang Mu Lee, Director General U Kyaw Win of DOA, officials and staff members from Korea and Myanmar, teachers and students from SAl attended the ceremony. The team carried out an inspection and fixing donors' plates on donated project machineries, agro-equipments, vehicles, computers and printer, furniture, tools and so forth. Demonstration farm for paddy rice, fruits and vegetables was laid out in April, 2012. Twenty nine Korean rice varieties and many Korean vegetable varieties were introduced into GAP Project farm to check the suitability of the varieties under Myanmar growing conditions. Paddy was cultivated three times in DAR and twice in SAl. In June 2012, vinyl houses were started to be constructed for raising seedlings and finished in December 2012. Fruit orchard for mango, longan and dragon fruit was established in June, 2012. Vegetables were grown until successful harvest and the harvested produce was used for panel testing and distribution in January 2013. Machineries for postharvest handling systems were imported in November 2012. Setting the washing line for vegetables were finished and the system as run for testing in June 2013. New water tanks, pine lines, pump house and electricity were set up in October 2013.