• Title/Summary/Keyword: 스펙트럼가속도

Search Result 165, Processing Time 0.021 seconds

Ground Motion Evaluation from the Fukuoka Earthquake (후쿠오카 지진('05. 3. 20, M=7.0)의 지진동 감쇠특성 분석)

  • Park, Dong-Hee;Yun, Kwan-Hee;Chang, Chun-Joong;Choi, Weon-Hack;Lee, Dae-Soo
    • Journal of the Korean Geophysical Society
    • /
    • v.8 no.3
    • /
    • pp.109-113
    • /
    • 2005
  • The ground-motion (GM) attenuation relations available in Korea has required the validation process for large earthquakes since most of them were developed based on small earthquake database. The Fukuoka earthquake (M=7.0) that occurred near the Korean Peninsula provides invaluable data to indirectly evaluate the attenuation characteristics of the strong GM in Korea. The GM levels (PGA, SA) obtained from the KIK-net downhole stations near the epicenter (R<100km) are reasonably predicted by the GM attenuation relation developed by KEPRI in 2003 for the Kori NPP site, the result of which validates the use of KEPRI GM attenuation relation for predicting GM induced by future large earthquakes. Also, the comparison between the Osaki spectra and response spectra of KIK-net downhole data reveals that the amplitude levels of Osaki spectra are higher than the spectra from KIK-net stations which are believed to be installed at the seismic basement.

  • PDF

Design Methods of the Longitudinal Motion-Limiting Devices in Multi-Span Continuous Bridges (다경간연속교의 교축방향 이동제한장치의 설계방법)

  • 전귀현;이지훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.4
    • /
    • pp.145-154
    • /
    • 1998
  • The motion-limiting devices can be used for reducing the maximum and residual displacements of the multi-span continuous bridges with inelastic elements such as isolation bearings and plastic hinges formed in piers. For the design of motion-limiting device, the nonlinear time history analysis is required. But the time history analysis is time consuming and very complex. This study suggests the simple design procedure of the motion-limiting devices using the equivalent elastic analysis method and the acceleration-displacement spectrum concept. The suggested design procedure can be used very effectively for determining the location and gap size of the motion-limiting devices.

  • PDF

Evaluation of Subsurface Liquefaction through Spectrum Intensity at Surface (지표면 스펙트럼 강도를 통한 지반의 액상화 평가에 대한 연구)

  • ;Towhata, Ikou
    • Geotechnical Engineering
    • /
    • v.14 no.2
    • /
    • pp.9-20
    • /
    • 1998
  • The earthquake-induced liquefaction of ground brings high possibility of failure of lifeline. If subsurface liquefaction is detected immediately after an earthquake the damage caused by the failure of lifeline can be reduced. The goal is achieved by deploying many accelerometers in the area of possible liquefaction and collecting records through a wireless network. This paper attempts to develop a measure to interpret the collected data oft surface motion and to assess the thickness of liquefied layers. For this purpose. both analysis of earthquake records and shaking table tests on model ground were carried out. It was shown that the thickness of liquefied layers can be assessed by using the maximum acceleration and the spectrum intensity at the surface.

  • PDF

Dynamic Analysis of Fixed Offshore Structures Subjected to Random Waves (불규칙파에 대한 고정해양구조물의 동적해석)

  • Yun, Chung Bang;Choi, Jung Ho;Ryu, Jeong Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.5 no.2
    • /
    • pp.1-9
    • /
    • 1985
  • Two methods for the dynamic analysis of fixed offshore structures subjected to random waves are studied. They are the frequency domain method using the equivalent linearization of the nonlinear drag force, and the time domain method utilizing the Monte Carlo simulation technique for time series of random wave particle velocities and accelerations. Example analyses are carried out for two structures with different structural characteristics and for various wave conditions. A comparison has been made between the results obtained by two methods.

  • PDF

Evaluations of Velocity Response Spectrum of Seismic Base and Response Displacement for the Seismic Design of Underground Structures (지중구조물 내진설계를 위한 기반면의 속도 응답스펙트럼 및 응답변위 산정기법에 대한 연구)

  • 윤종구;김동수;유제남
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.211-221
    • /
    • 2003
  • The response displacement method is the most frequently used method for seismic design of underground structures. This method is pseudo-static method, and the evaluations of velocity response spectrum of seismic base and response displacement of surrounding soil are the most important steps. In this study, the evaluation of velocity response spectrum of seismic base according to the Korean seismic design guide and the simple method of calculating the response displacement were studied. It was found that velocity response spectrum of seismic base can be estimated by directly integrating the ground-surface acceleration response spectrum of soil type S$_A$, and the evaluation of the response displacement using double cosine method assuming two layers of soil profile shows the advantages in the seismic design.

Instrumental Seismic Intensity based on Fourier Acceleration Spectra of the earthquake ground-motion (지진파의 가속도 푸리에스펙트럼 크기를 이용한 계측진도 평가)

  • Yun, Kwan-Hee;Park, Dong-Hee;Park, Se-Moon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.6
    • /
    • pp.27-37
    • /
    • 2009
  • A method of instrumentally estimating seismic intensity (MMI) based on the Fourier Acceleration Spectrum of earthquake ground-motion, the so-called 'FAS MMI method' of Sokolov and Wald (2002), was evaluated for its applicability to Korea based on the empirical models of mean (m) and standard deviation (${\sigma}$) for Korea according to individual seismic intensity for MMI ${\leq}$ IV (Yun et al., 2009). This evaluation showed that the error in estimating the seismic intensity using the FAS MMI method is ${\sigma}$ = 0.74 MMI, and was further reduced to ${\sigma}$ = 0.61 MMI if the dependency of the error on earthquake magnitude and distance is additionally corrected. It is also shown that FAS MMI based on the FAS semi-empirically evaluated from small earthquakes for damaging earthquakes in Korea with maximum MMI ${\geq}$ VI could predict the observed MMI with the maximum error of 0.63 by using the combined FAS m-${\sigma}$ models of Korea for MMI ${\leq}$ IV and global region for MMI ${\geq}$ V.

Evaluation of Peak Ground Acceleration Based on Seismic Design Standards in Sejong City Area Using Gyeongju-Pohang Type Design Seismic Waves (경주·포항형 설계지진파를 활용한 세종시 지역의 내진설계기준 지표면최대가속도 성능평가)

  • Oh, Hyun Ju;Lee, Sung Hyun;Park, Hyung Choon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.41-48
    • /
    • 2024
  • In 2017, the Ministry of the Interior and Safety conducted research for the revision of seismic design standards and performed studies on standard design response spectra. As a result, the Common Application Guidelines for Seismic Design Standards were introduced, and these guidelines have been implemented in the national design standards of the Ministry of Land, Infrastructure, and Transport for practical use. However, it should be noted that the research for proposing standard design response spectra during the 2017 revision was conducted before the occurrence of the significant seismic events in South Korea, such as the 2016 Gyeongju Earthquake and the 2017 Pohang Earthquake. To account for these recent major earthquakes, this study adjusted the standard design spectra based on the records of the 2016 Gyeongju Earthquake and the 2017 Pohang Earthquake and conducted ground response analyses accordingly. The results revealed variations in peak ground acceleration (PGA) at the ground surface even within the same ground classification. It was confirmed that this variation can lead to overestimation or underestimation of seismic loads.

Dynamic Analysis of Steel Jackets under Wave and Earthquake Loadings I : Linear and Non-linear F. E. Formulation (파랑 및 지진하중을 받는 스틸자켓의 동적해석 I : 선형 및 비선형 유한요소 정식화)

  • 김문영;백인열;고진석
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.5
    • /
    • pp.1-11
    • /
    • 2001
  • The purpose of this study is to develop the main program and pre/post processor for the geometric and plastic non-linear analysis of steel jacket structures subjected to wave and earthquake loadings. In this paper, steel jackets are modelled using geometric non-linear space frames and wave loadings re evaluated based on Morrison equation using the linear Airy theory and the fifth Stokes theory. Random wave is generated using JONSWAP spectrum. For earthquake analysis, dynamic analysis is performed using artificial earthquake time history. Also the plastic hinge method is presented for limit analysis of steel jacket. In the companion paper, the pre/post processor is developed and the numerical examples are presented for linear and non-linear dynamic analysis of steel jackets.

  • PDF

Seismic Response Estimation of Water Extinguishing Facilities using Shaking Table Tests (진동대 실험을 통한 수계 소화설비의 지진응답평가에 관한 연구)

  • Nam, Min-Jun;Park, Seung-Hee;Kim, Dong-Joon;Choi, Jun-Sung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.9-18
    • /
    • 2012
  • In this study, a shaking table test was performed for the evaluation of water extinguishing facilities. Water extinguishing facilities, such as a general pipe, a seismic pipe (Loof type) and a pump, were used in the experiment. This captured the dynamic characteristics of water extinguishing systems by earthquake records at El-Centro with a 50%, 70%, 100%, 120% level. As a result, seismic type facilities have excellent seismic performance compared to general facilities. By using the acceleration response spectrum, not only is the performance evaluation of water extinguishing facilities able to be determined, but also the deformation of facilities in low earthquake levels can be known. This proposed approach can determine the seismic performance evaluation of water extinguishing facilities and verify seismic performance criteria.

Generation of Artificial Time History Covering Design Response Spectrum by Two Modification Functions (이중 수정함수 적용을 통한 설계응답스펙트럼 포괄 인공지진파의 생성)

  • Park, Gun;Hong, Ki Nam;Han, Sang Hoon;Kim, Jae Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.1
    • /
    • pp.1-11
    • /
    • 2016
  • The domestic and foreign seismic design codes have specified that time history covers design response spectrum when the response spectrum, which calculated from the time history, is smaller than the design response spectrum at five points or less. In order to verify the design codes, time history analysis for a pier was performed by using five artificial time histories conforming design code with various characteristics and its member forces were evaluated according to them. It was confirmed from analysis results that, regardless of the conformity to design code requirement, seismic design using the artificial time histories could not guarantee earthquake resistant design if the response spectrum from them is lower than design response spectrum at the similar period to the natural frequency of structure. Thus, the time history generating method to make its acceleration response spectrum to be greater than design response spectrum at all period was proposed by two modification function in this study. It was also verified whether time histories from the proposed method satisfy the seismic design codes or not.