• Title/Summary/Keyword: 스토커소각로

Search Result 11, Processing Time 0.024 seconds

A Numerical Study of the 2-D Cold Flow for a Qubec City Stoker Incinerator (큐벡시 스토커 소각로 2차원 비반응 유동장 수치해석)

  • 박지영;송은영;장동순
    • Journal of Energy Engineering
    • /
    • v.2 no.3
    • /
    • pp.268-275
    • /
    • 1993
  • A series of parametric investigations are performed in order to resolve the flow characteristic of a Quebec city stoker incinerator. The parameters considered in this study are five internal configurations of the Quebec city stoker itself and its modified ones, primary air velocity, the injection velocity and angle of the secondary air, and the reduction of the stoker exit area. A control-volume based finite-difference method by Patankar together with the power-law scheme is employed for discretization. The resolution of the pressure-velocity coupling is made by the use of SIMPLEC algorithm. The standard, two equation, k-$\varepsilon$ model is incorporated for the closure of turbulence. The size of recirculation region, turbulent viscosity, the mass fraction of the secondary air and pressure drop are calculated in order to analyze the characteristics of flow field. The results are physically acceptable and discussed in detail. The flow field of the Quebec city stoker shows the strong recirculation zone together with the high turbulence intensity over the upper part of the incinerator.

  • PDF

Secondary Air Nozzle Design of Combustion Chamber of 50 ton/day Commercial Incinerator (50톤/일 상업용 소각로 연소실 2차 공기 노즐 설계)

  • 박병수;이진욱;서정대;허일상
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.05a
    • /
    • pp.127-132
    • /
    • 1999
  • 우리나라의 도시폐기물 소각로는 화격자 위에 폐기물을 공급하고 화격자 밑에서 공기를 공급하는 스토커식 소각로를 대부분 채택하고 있다. 이러한 스토커 소각로 연소실내에서는 매우 복잡한 연소현상이 발생하는데, 연소실로 투입된 쓰레기는 먼저 건조부에서 수분의 건조가 일어나고, 화격자의 구동에 의해 쓰레기가 혼합 및 이송되면서 열분해, 가스화, 가연성분의 탈휘발화 및 연소, 일부 고정탄소의 표면연소 등의 반응이 일어난다. 그리고 1,2차 연소실에서는 휘발분 및 비산된 고체의 연소가 일어나는데, 이때 대류 및 복사열전달 등의 복잡한 현상을 수반하는 유동장이 형성된다. 더욱이 불균질한 특성을 갖는 쓰레기층 내에서의 복잡한 현상으로 인하여 발생하는 경계조건 설정의 불확실성으로 연소실내의 연소 현상을 전산해석하는 데에는 상당한 어려움이 있다.(중략)

  • PDF

차세대 도시폐기물 소각설비의 이해

  • Seong, Baek-Nam
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.38 no.10
    • /
    • pp.5-11
    • /
    • 2009
  • 본 내용은 당사가 Turn-key방식으로 설계시공일괄입찰방식으로 시공후 현재 운영중인 C시 광역소각시설의 설계 시공 및 운영을 중심으로 개요와 특징에 대해서 소개하고자 한다. 본 프로젝트는 현재 시공이 완료되어 정상가동중에 있으며 사업의 배경 및 목적 개요, 그리고 이 프로젝트에서 국내 최초 적용한 병행류식 스토커 타입 소각로 및 처리프로세스를 소개하고자 한다.

  • PDF

Evaluation of Operation Status for Incineration Facility Using Performance Index (소각시설 이행지표를 활용한 운영 현황 평가)

  • Kim, Jong-Hwan;Park, Joon-Seok;Phae, Chae-Gun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.507-520
    • /
    • 2016
  • This research was performed to evaluate incineration facilities with different scale and type using performance index. Incineration facilities of 28 units, which occupying about 15% of 184 units in nationwide, were selected for questionnaire survey. The facilities were classified in scale with large(${\geq}100t/d$), middle(50~<100 t/d), small(<50 t/d) ones, and in type with stoker, pyrolysis, fluidized bed. Performance index was composed of technological, economical, and environmental items, which have 6, 10, and 30 kinds of questions, respectively. As a result of scale evaluation, large scale facility has higher score than small one in all technological, economical, and environmental items. In overall evaluation of the facilities with different type, stoker incinerator has higher score of 65.3 than 59.0 of fludized bed and 58.3 of pyrolysis. It was shown that there was significant difference in economical evaluation field, in all technological, economical, and environmental items.

A Numerical Study for Effective Operation of MSW Incinerator for Waste of High Heating Value by the Addition of Moisture Air (함습공기를 이용한 고발열량 도시폐기물 소각로의 효율적 운전을 위한 수치 해석적 연구)

  • Shin, Mi-Soo;Shin, Na-Ra;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.115-123
    • /
    • 2013
  • Stoker type incinerator is one of the most popular one used as municipal solid waste (MSW) incineration because, in general, it is quite suitable for large capacity and need no preprocessing facility. Nowadays, however, since the combustible portion of incoming MSW increases together with the decrease of the moisture content due to prohibition of directly burying food waste in landfill, the heating value of waste is remarkably increasing in comparison with the early stage of incinerator installation. Consequently, the increased heating value in incinerator operation causes a number of serious problems such as reduction of waste amount to be burned due to the boiler heat capacity together with the significant NO generation in high temperature environment. Therefore, in this study, a series of numerical simulation have been made as parameters of waste amount and the fraction of moisture in air stream in order to investigate optimal operating condition for the resolution of the problems associated with the high heating value of waste mentioned above. In specific, a detailed turbulent reaction flow field calculation with NO model was made for the full scale incinerator of D city. To this end, the injection method of moisturized air as oxidizer was intensively reviewed by the addition of moisture water amount from 10% and 20%. The calculation result, in general, showed that the reduction of maximum flame temperature appears consistently due to the combined effects of the increased specific heat of combustion air and vaporization heat by the addition of water moisture. As a consequence, the generation of NOx concentration was substantially reduced. Further, for the case of 20% moisture amount stream, the afterburner region is quite appropriate in temperature range for the operation of SNCR. This suggests the SNCR facility can be considered for reoperation. which is not in service at all due to the increased heating value of MSW.

A Numerical Study on the Combustion Characteristics for Stoker Type Incinerator with Various Injection Type of Secondary Air (2차 공기 주입방식에 따른 스토커형 소각로의 연소특성에 관한 수치해석적 연구)

  • Jung, Jin;Kim, Chang-Nyeong;Cho, Young-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.10
    • /
    • pp.835-842
    • /
    • 2003
  • A three dimensional numerical analysis has been conducted for a stoker type incinerator which has the capacity of 1.5 ton/hr. The objective of the present study is to predict the effects of swirl induced by secondary air and to find an optimal operating condition of the incinerator. In this study, combustion characteristics such as distributions of temperature, velocity and concentration of each species have been examined with various injection types of secondary air and with different flow rates of secondary air in the incinerator. It is found that the secondary air injection on the combustion process makes the path of fluid particle longer in the combustor and enhances the mixing between air and combustion gas by arousing a swirl. Therefore, the injection type of secondary air can be an important key in the design process of incinerator.

Optimal Operation of Medium Sized Incinerator to Minimize PCDD/Fs Emission (중형 소각로 다이옥신 배출 저감을 위한 최적 운전인자)

  • Yoo, Dong-Joon;Koo, Ja-Kong;Jeong, Seung-Ik
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.21 no.4
    • /
    • pp.44-49
    • /
    • 2013
  • An establishment of dioxin-reduction operating skill for medium sized incineration facility is urgently needed in Korea with nearly 90% of medium sized incineration. Using lattice stoker incineration processing the capacity of 20 tons industrial general waste per day, similar properties of the household waste, dioxin-reduction is derived in optimum operating condition and parameters. As a result, CO haunting which is the minimization of frequency is found as the major parameter to minimize dioxin.

The Study of Numerical Simulation on the Thermal Flow Performance for the Design of Low Emission Stoker Type Municipal Waste Incinerator (저공해 스토커형 도시폐기물 소각로 설계를 위한 열유동 수치해석 연구)

  • 전영남;송형운;김미환
    • Journal of Environmental Science International
    • /
    • v.11 no.6
    • /
    • pp.543-551
    • /
    • 2002
  • A Numerical simulation on the thermal flow performance was carried out to propose the incinerator type for the domestic refuses and to investigate the design factor and operating conditions. The SSTI(Standard Stoker Type Incinerator) proposed in this study was modified from the type with central f)ow. It has the characteristics of good mixing between refuse and hot combustion gas in primary combustion chamber and between unburned gas inflowing and secondary air jet in secondary chamber. By predictive results, the SSTI was no recirculation zone in secondary chamber so that mixing time was increased with high residence time. It has good characteristics of combustion and low emission. Parametric screening studies have been understood with phenomenon of combustion in incinerator.

The study on the combustion model and combustion characteristics for stoker type incinerator (스토커형 소각로의 연소특성 및 연소 모델에 관한 연구)

  • Kim, Ho-Yeong;Hwang, Ho-Yeong;Jeon, Cheol-Gyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.5
    • /
    • pp.627-639
    • /
    • 1998
  • A combustion model for the incineration of municipal solid waste(MSW) in the stoker type incinerator was developed by considering the variation of physical composition of MSW. Theoretical analysis and numerical simulation for the combustion characteristics in incinerator were conducted by using the present model and the effects of compositional variation on the incineration characteristics of MSW was examined theoretically. It is found that large excess air enhances drying, but depresses volatilization. For the large value of moisture content, pyrolysis is fast but drying is slow. As the value of plastic content increases, devolatilization becomes slower. Larger amount of primary air supply to the rear side of stoker leads to increase the possibility of delaying the combustion.