• Title/Summary/Keyword: 스텝

Search Result 834, Processing Time 0.023 seconds

A New Resource Allocation Algorithm of Functional Units to Minimize Power Dissipation (전력소비 최소화를 위한 새로운 펑션유닛의 자원 할당 알고리듬)

  • Lin, Chi-Ho
    • Journal of IKEEE
    • /
    • v.8 no.2 s.15
    • /
    • pp.181-185
    • /
    • 2004
  • This paper reduces power dissipation with the minimum switching activity of functional units that have many operators. Therefore, it has more effects of power dissipation that operator dissipation to reduce power dissipation of whole circuit preferentially. This paper proposes an algorithm that minimize power dissipation in functional units operations that affect much as power dissipation in VLSI circuit. The algorithm has scheduled operands using power library that has information of all operands. The power library upgrades information of input data in each control step about all inputs of functional units and the information is used at scheduling process. Therefore, the power dissipation is minimized by functional units inputs in optimized data. This paper has applied algorithm that proposed for minimizing power dissipation to functional unit in high level synthesis. The result of experiment has effect of maximum 9.4 % for minimizing power dissipation.

  • PDF

Design and Fabrication of a 3-dimensional Diagnostic Ultrasonic Probe (3차원 입체 영상 진단용 초음파 프로브의 설계 및 제작)

  • Eun, Hong;Lee, Su-Sung;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.8
    • /
    • pp.766-771
    • /
    • 2002
  • In this study, we have developed a 3-dimensional diagnostic ultrasonic sector probe using a convex type ultrasonic probe with 128 active elements. The probe was made to operate at the center frequency of 4.5㎒ with the bandwidth of 66%. The driving part was designed to rotate the axis of the convex probe by means of a step motor equipped with reduction gears and spur gears attached to the motor so that the probe could enable us to acquire a series of 2-dimensional images to construct a 3-dimensional image. Acoustic cover of the probe was made of polymers to have the same radius of rotation as that of the convex probe. The controllability of the rotation angle and the structural stability of the probe were confirmed through experimental 3-dimensional images obtained using the developed 3-dimensional sector probe.

A Survey on Neural Networks Using Memory Component (메모리 요소를 활용한 신경망 연구 동향)

  • Lee, Jihwan;Park, Jinuk;Kim, Jaehyung;Kim, Jaein;Roh, Hongchan;Park, Sanghyun
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.7 no.8
    • /
    • pp.307-324
    • /
    • 2018
  • Recently, recurrent neural networks have been attracting attention in solving prediction problem of sequential data through structure considering time dependency. However, as the time step of sequential data increases, the problem of the gradient vanishing is occurred. Long short-term memory models have been proposed to solve this problem, but there is a limit to storing a lot of data and preserving it for a long time. Therefore, research on memory-augmented neural network (MANN), which is a learning model using recurrent neural networks and memory elements, has been actively conducted. In this paper, we describe the structure and characteristics of MANN models that emerged as a hot topic in deep learning field and present the latest techniques and future research that utilize MANN.

The Effect of Stair Depth on Ground Reaction Force Parameters - Asymmetric and Variability Indices - (계단보행 시 계단 너비가 지면반력 파라미터에 미치는 영향 -비대칭 지수 및 일관성 지수-)

  • Yoon, Suk-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.1
    • /
    • pp.169-178
    • /
    • 2008
  • The goals of this study were to provide data of 3 dimensional ground reaction force(GRF) parameters during stair ascent and descent on three different stair runs and to investigate variability and asymmetry index of them. 10 healthy adults participated in this study and performed 7 different types of gait with 10 trials each. After data analysis, following results were found. Firstly, stair run did not affect on the pattern of GRF parameters, coefficient of variation and asymmetry index. Secondly, a significant different GRF pattern was found between level walking and stair walking. Especially, ascending stair walking has only large Fz1 and small Fz3 while level walking and descending stair walking have a "M" shape connected by Fz1, Fz2 and Fz3. Thirdly, only vertical GRF parameters of stair walking revealed acceptable coefficient of variation and asymmetry index.

A Study on Partial Resonant AC-DC Chopper of Power Factor Correction (역률개선형 부분공진 AC-DC 초퍼에 관한 연구)

  • Kwak, Dong-Kurl
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.3
    • /
    • pp.19-25
    • /
    • 2008
  • In this paper, author proposes a novel step-up AC-DC chopper operated with power factor correction(PFC) and with high efficiency. The proposed chopper behaves with discontinuous current control(DCC) of input current. The input current waveform in the proposed chopper is got to be a discontinuous sinusoid form in proportion to magnitude of ac input voltage under the constant duty cycle switching. Therefore, the input power factor is nearly unity and the control method is simple. In the general DCC chopper, the switching devices are turned-on with the zero current switching, but turn-off of the switching devices is switched at current maximum value. To achieve a soft switching of the switching rum-off, the proposed chopper is used a new partial resonant circuit. The result is that the switching loss is very low and the efficiency of chopper is high.

  • PDF

Electromyographic Analyses of the effects of different foot positions during exercise on a stair-climbing machine (스텝 운동 기구를 사용한 운동 시 발의 위치가 하지 근육 활동에 미치는 영향 분석)

  • Chae, Woen-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.1
    • /
    • pp.207-219
    • /
    • 2005
  • The purpose of this study was to determine the effect of the foot rotation on the lower limb muscles. Fourteen subjects performed step-up/step-down at a cadence of 80 beats/min, exercises with the foot neutral, $35^{\circ}$ internally rotated, and $35^{\circ}$ externally rotated, respectively. For each variable, a one-way analysis of variance (ANOVA) was used to determine whether there were significant differences between genders and among the eight types of jump. When a significant difference was found in jump type, post hoc analyses were performed using the Tukey procedure. A confidence level of p < .05 was used to determine statistical significance. The results showed that significant changes in averaged IEMG values occurred with the internal rotation of the foot in the lateral gastrocnemius during the knee extension, and in the semitendinosus during the knee flexion. During the knee extension, however, the internal rotation of the foot produced a significantly lower Averaged IEMG values than the neutral foot position in the medial gastrocnemius. The results also found that the peak IEMG activity of the rectus femoris during the knee extension for the external rotation of the foot was Significantly higher than the corresponding values in the neutral position of the foot, while the intenal rotaion of the foot exhibited a significant difference with the neutral position of the foot in the semitendinosus during the knee flexion. In general, the foot rotation position did not influence the average IEMG and Peak IEMG values of most muscles. The practice of adopting foot rotation to selectively strengthen individual muscles of the lower limb was not supported by this study. The external rotation of the foot produced high muscle activities in the quadriceps during the knee extension. For the knee extension, therefore, maintaining a laterally rotated position should be need for stable and comfortable position.

The Effect of Upper Extremity Usage on the Soccer Instep Kick Motion (축구 인스텝 킥 시 상지의 이용 유무가 하지의 운동학적 변인에 미치는 영향)

  • Chae, Woen-Sik;Kang, Nyeon-Ju;Kim, Jong-Woo;Yun, Chang-Jin;Chae, Su-Duk;Seok, Chang-Huk;Park, Gi-Yong;Lim, Young-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.1
    • /
    • pp.41-47
    • /
    • 2010
  • The purpose of this study was to evaluate the kinematic effect of upper extremity usage for the scoccer instep kick motion. Ten male university students were recruited as the subjects. Temporal parameters, ball velocity, velocity of CG, angle of segment, angular velocity, and trunk orientation angle were determined for each trial. The results showed that temporal parameters in WU and WORU were significantly less than those found in WOU during pre impact phase. These indicated that no usage of upper extremity may increase excessive setup time in order to improve the accuracy of instep kick. Angle of right knee in WOU at LC was significantly greater than corresponding value for WU since angular momentum contributions of the lower limb were not effectively balanced by contributions of the upper limb. We found that the lower extremity movement was controlled by lateral movement in the trunk as a result of no usage of the upper extremity, resulting in the relatively greater trunk rotation in WOU.

Design and Implementation of 3-Dimensional Laminated Dielectric Ceramic Filter in Waveguide Using a DWFD Program (DWFD 프로그램을 이용한 3차원 적층 유전체 세라믹 도파관 필터의 설계 및 제작)

  • Kim, Jong-Chel;Jang, Young-Soo;Kim, Seung-Wan;Lee, Kie-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.5
    • /
    • pp.515-524
    • /
    • 2013
  • The program for dielectric ceramic waveguide filter was developed based on the direct coupled filter of ${\lambda}/2$ step impedance prototype. This developed program was called DWFD(Direct coupled Waveguide Filter Design). The filter was designed by 3-dimensional laminated type to reduce the size at the 1 GHz. S scattering matrix for this filter was calculated using the DWFD program. The width of inductive irises for laminated filter was computed by HFSS simulation tool. This waveguide filter was designed by 8 poles with bandwidth 25 MHz at the center frequency 881.5 MHz. By using a dielectric constant 35.4 and laminated type, the size of filter was reduced with width 50 mm and height 48 mm rapidly. We can see that the measured results agree well with the HFSS simulation result. Finally, this paper is shown that the design and implementation of waveguide filters can be presented by using DWFD program simply.

Analysis of Body Induced Current in Middle Frequency Range Using Quasi-Static FDTD (중간주파수 대역에서 준정적(Quasi-Static) FDTD 기법을 이용한 인체 유도전류 분석)

  • Byun, Jin-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.141-149
    • /
    • 2009
  • In this paper, quasi-static FDTD method is implemented by FORTRAN programming, and it is used for analysis of body induced current in middle frequencies. The quasi-static FDTD program is validated by comparing the calculation result with analytic solution of the test model, to which it is difficult to apply conventional FDTD. It is confirmed that the time-step is reduced by $5.68{\times}10^6$ times. Using validated numerical technique, body induced current distribution in high resolution 3-D human model is calculated for 20[kHz] magnetic field exposure and 1[MHz] electric field exposure. Also, the effect of grounding condition of both feet on the distribution and amplitude of the induced current is analyzed. It is expected that this research can be applied to various fields including safety assessment of body induced current and development of diagnosis devices using bio-electricity.

A New Sensorless Control Scheme Using Simple Duty Feedback Technique in DC/DC Converters (DC/DC 컨버터에서 Duty Feedback을 이용한 새로운 센서리스 제어기법)

  • 이동윤;노형주;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.6
    • /
    • pp.554-562
    • /
    • 2002
  • This paper presents a new sensorless control scheme using simple duty signal feedback technique in DC/DC converters. The proposed Duty Feedback Control(DFC) has the characteristics that they show the same as operation performance of current mode control by using duty feedback technique without current sensor as well as present faster dynamic response performance than conventional Sensorless Current Mode(SCM) control in case that input source is perturbed by step change or DC input source includes the harmonics. Also, the proposed control scheme has good noise immunity and simple control circuits since they have one feedback loop, and can be applied to all DC/DC converters. The concept and control principles of the proposed control scheme are explained in detail and the validity of the proposed control scheme is verified through several interesting simulated and experimental results.