• 제목/요약/키워드: 스터링 냉동기

검색결과 40건 처리시간 0.026초

충진압력에 따른 KIMM-E1 스터링 극저온 냉동기에 관한 연구 (Study of KIMM-E1 Stirling Cryocooler Performance with Different Charging pressure)

  • 박성제;홍용주;고득용;김효봉;오군섭;염한길;김종학
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.33-36
    • /
    • 2001
  • A free piston and free displacer(FPFD) Stirling cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM(Korea Institute of Machinery & Materials). The FPFD Stirling cryocooler employs 1) the Stirling cycle for refrigeration, 2) linear motors for driving the cryocooler, 3) spring and gas support systems, and 4) fine gap for clearance seals. It is the most suitable design for a mechanical cryocooler utilized in night vision environment. The experimental results show KIMM-E1 Stirling cryocooler (with expander manufactured by KIMM) has the higher cooling power and faster response time at optimum charging pressure.

  • PDF

스터링 극저온 냉동기 성능의 운전주파수 의존성에 관한 연구 (Study of the Dependency of the Stirling Cryocooler′s Thermodynamic Performance on the Operating Frequency)

  • 홍용주;박성제;김효봉;유병건;최영돈
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.140-144
    • /
    • 2002
  • A free piston and free displacer (FPFD) Stirling cryocooler has been widely used for the cooling infrared and cryo-sensor. The thermodynamic performance of the free piston and free displacer type (FPFD) Stirling cryocooler is highly dependent on the operating frequency of the linear compressor and the natural frequency of the displacer. In this study, to find optimal relation between operating and natural frequency of the displacer the dynamic characteristics of the displacer in the expansion space of the Stirling cooler was investigated by experiment. The experimental results show that the Stifling cryocooler has maximum cooling capacity at the operating frequency of about 0.8 times of the natural frequency of displacer. Therefore the operating frequency of the Stirring cryocooler should be determined by natural frequency of the linear compressor and displacer.

적외선 센서 냉각용 스터링 냉동기의 수명/신뢰성 시험 (Reliability Test of the Stirling Cryocooler for cooling infrared detector)

  • 박성제;홍용주;김효봉;유병건;이기백
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.156-159
    • /
    • 2003
  • A free piston and free displacer(FPFD) Stirling cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM(Korea Institute of Machinery & Materials). Our coolers are specifically designed to work in the thermal imaging device and to meet requirements such as cooling capacity, COP and high reliability. In this work, Stirling cryocooler is designed, manufactured and fabricated, and performance characteristics are investigated. This cooler delivers approximately 0.5W cooling at 77K for 30W ∼ 40W of input power from AC power supply. And, after the climate performance and reliability for the cryocooler is discussed, operating test without cooling load at the cold end is performed.

  • PDF

열상장비용 스터링 극저온 냉동기 특성평가 (III) : 열환경시험 (The performance evaluation of Stirling cryocooler for thermal imaging system (III) : Thermal environmental test)

  • 김양훈;박성제;홍용주;김효봉;고득용;이승홍;나종문
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.163-166
    • /
    • 2003
  • This paper presents the results of a series of performance tests for the Stilting cryocooler. Infrared sensor systems incorporating cryocoolers are required to be qualified to the appropriate environmental specification. Linear drive Stilting cryocooler have matured to the stage of undergoing formal qualification test program The thermal environmental test of the Stilting cryocooler is presented in this paper. We performed that low and high temperature keeping test from -4$0^{\circ}C$ to +6$0^{\circ}C$ and operating test at high and low temperature cyclic range with acceptance tests performed at scheduled intervals. Cooling capacity was determined as a function of cooler components temperatures at the compressor, hot end and cold tip. Tests performed on this cooler have been successful with a measured cooling performance of more than 0.8W@80K for 23$^{\circ}C$ ambient temperature with 40 $W_{ac}$ input power.

  • PDF

열상장비용 스터링 극저온 냉동기 특성평가 (II) : 수명시험 (The performance evaluation of Stirling cryocooler for thermal imaging system (II) : Life test)

  • 홍용주;박성제;김효봉;김양훈;권영주
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.324-327
    • /
    • 2003
  • The needs for the cryocooler which has high reliability and long MTTF are increased in the military and commercial thermal imaging system The gas contamination wear, leakage of the working fluid, fatigue and etc. have the significant effects on the reliability and MTTF(Mean Time To Failure) or MTBF(Mean Time Between Failure) of the Stirling cryocooler. In the KIMM, the Stilting cryocooler with the linear compressor was released after the several performance tests were performed. This paper describe the experimental facility for the MTTF evaluation and some typical results of the Stilling cryocooler.

  • PDF

열상장비용 스터링 극저온 냉동기 특성평가 (I) : 성능시험 (The performance evaluation of Stirling cryocooler for thermal imaging system (II) : Performance test)

  • 박성제;홍용주;김효봉;김양훈;이성래;이기백;나종문
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.320-323
    • /
    • 2003
  • This paper presents the results of a series of performance tests for the Stilting cryocooler. A free piston and free displacer(FPFD) Stilting cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM. Our coolers are specifically designed to work in the thermal imaging device and to meet requirements such as cooling capacity, COP and high reliability. In this work, Stilting cryocooler is designed, manufactured and fabricated, and performance characteristics for the cooling capacity / applied input power and cool down time are investigated. This cooler delivers approximately 0.9W cooling at 80K for 30W ~ 40W of input power. And, It takes approximately 2 minutes to cool down to 80K at the ambient temperature of 23$^{\circ}C$.

  • PDF

열상장비용 스터링 극저온 냉동기 특성평가 (IV) : 진동, 소음, 누설시험 (The performance evaluation of Stirling cryocooler for thermal imaging system (IV) : Vibration, Noise, Leak test)

  • 박성제;홍용주;김효봉;김양훈;최상규;나종문
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.167-170
    • /
    • 2003
  • This paper presents the results of a series of performance tests for the Stilting cryocooler. A free piston and free displacer(FPFD) Stilting cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM. Our coolers are specifically designed to work in the thermal imaging device and to meet requirements such as cooling capacity, COP and high reliability. In this work, Stilting cryocooler is designed, manufactured and fabricated, and performance characteristics for the vibration, acoustic noise, EMI and leak rate are evaluated. Vibration outputs are measured to 20KHz for compressor and expander, respectively. And, the objective of noise test is a noise level, less than 30㏈ at 5 m. EMI tests are carried out according to the standard MIL-STD-461C tests RE01 and RE02. Leak test for the Stilting cryocooler is performed by bombing method.

  • PDF

일체형 스터링 냉동기 성능에 미치는 주요 인자에 관한 연구 (A Study on the Principal Factors for the Stirling Refrigerator Performance)

  • 김대웅;박성제;홍용주;김효봉;고상철
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권1호
    • /
    • pp.67-70
    • /
    • 2008
  • Performance of integral type Stirling refrigerator used for cooling infrared detector is affected by principal factors such as design factors and operating factors. Operating factors include charging pressure and operating frequency. The purpose of this paper is to examine the basic design analysis on the integral type Stirling refrigerator and the changes in performance through experiments on operating factors.

일체형 스터링 냉동기의 설계, 제작 및 성능특성에 관한 연구 (A study on the performance characteristics of rotary type Stirling cryocooler)

  • 박성제;홍용주;김효봉;김양훈
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권1호
    • /
    • pp.54-58
    • /
    • 2006
  • Stirling cryocooler is relatively compact, reliable, commercially available. and uses helium as a working fluid. Over the past decade and a half, there has been rapid development of Stirling cryocooler, mainly for military and space applications. Stirling cryocoolers have been widely used lot the cooling of infrared sensors and high temperature superconducting filters to the temperature of the liquid nitrogen. The Stirling cryocooler with the rotary compressor is applicable to the cooling device for the compact mobile thermal imaging system, because the cryocoolers have the compact structure and light weight. In this paper, integral Stirling cryocooler is designed, manufactured and fabricated, and performance characteristics are investigated. This cooler delivers approximately 0.6W cooling at 80K for 20W of input power from 24V DC power supply.

적외선 우주망원경 냉각시스템 시험모델 열설계 (THERMAL DESIGN OF A PROTOMODEL SPACE INFRARED CRYOGENIC SYSTEM)

  • 양형석;김동락;이병섭;김건희;이대희;박수종;남욱원
    • Journal of Astronomy and Space Sciences
    • /
    • 제23권2호
    • /
    • pp.153-160
    • /
    • 2006
  • 이 논문에서는 적외선 우주관측을 위한 냉각시스템 시험모델(PSICS, Protomodel Space Infrared Cryogenic System)의 설계를 위해 수행된 열해석 및 열설계 내용을 논의한다. 이 냉각시스템은 장래 진행될 위성 탑제용 적외선 우주 망원경의 냉각시스템 계발을 위한 예비연구를 위한 시스템이며, 테스트는 지상에서의 관측을 통해 수행된다. 냉각목표 온도는 80K이고, 80K에서 500mW의 냉각능력을 갖는 스터링 냉동기 1대가 냉각에 사용된다. 저열침입과 열부하의 바른 예측을 위해 냉각시스템의 전도, 복사 등의 각 열전달 모드에 대해 열부하를 산출하였고, 총 열부하는 복사열 차단 정도에 따라 $42{\sim}149mW$임을 알았다. 또한 냉각박스 표면의 온도분포는 0.12K 이하의 균일한 온도분포로 유지될 수 있음을 알았다. 이를 통해 80K에서 500mW의 냉동기를 이용하여 충분히 냉각시킬 수 있음을 확인하였다.