• Title/Summary/Keyword: 순환 Loop

Search Result 180, Processing Time 0.03 seconds

Bacterial Distribution and Relationship with Phytoplankton in the Youngsan River Estuary (영산강 하구의 박테리아 분포 및 식물플랑크톤과의 관계)

  • Kim, Se Hee;Sin, Yong Sik
    • Journal of Marine Life Science
    • /
    • v.4 no.2
    • /
    • pp.53-62
    • /
    • 2019
  • Heterotrophic bacteria are a major member of the microbial loop in the marine ecosystem and play an important role in the biogeochemical cycle decomposing organic matter. Therefore study of bacterial variation is important to understand the material cycle and energy flow of marine ecosystems. We investigated the monthly variations of bacteria and environmental factors in the Youngsan River estuary, and the correlation between bacteria and phytoplankton biomass (chlorophyll-a) including size-structure. As a result, bacteria of the Youngsan River estuary were higher in the surface than in the bottom layer, and higher in the summer than in winter. And the closer to the dike, the abundance increased, and it increased to the peaks in August, September, and June 2019 at the station closest to the dike. The chlorophyll-a also increases at the stations and time when the bacterial abundance was high and they correlates positively displaying no difference between size fractions. The results indicate that organic matter derived from phytoplankton has an effect on bacterial variation but no size-dependent effects. In addition, the seasonal pattern of bacteria increasing in proportion to the water temperature suggests the effect of water temperature on the growth of bacteria. No association of bacterial abundance variation with nutrient supply due to freshwater input was observed. In this study, dissolved oxygen was depleted and hypoxia was observed for a short time when a strong stratification was not developed. This may be resulted from the supply of organic matter from phytoplankton and the consumption of oxygen due to bacterial decomposition.

Optimum Pumping Rates of Ground-Water Heat Pump System Using Groundwater or Bank Infilterated Water (강변여과수와 천부 지하수를 이용하는 지하수 열펌프시스템의 적정유량)

  • Hahn, Jeong-Sang;Han, Hyuk-Sang;Hahn, Chan;Jeon, Jae-Soo;Kim, Hyong-Soo
    • Economic and Environmental Geology
    • /
    • v.40 no.6
    • /
    • pp.833-841
    • /
    • 2007
  • The groundwater heat pump system(GWHP) is one of the most efficient ground source heat pump system(GSHP) which uses low grade and shallow geothermal energy for cooling and heating purpose. The GWHP system shall be designed properly based on peak block load performance and optimum pumping rate of groundwater comparable to ground coupled heat pump system(GCHP). The optimum pumping rate depends on groundwater temperature at a specific site, size of plate heat exchanger, and total head loss occurred by whole system comprising pumps and pipings. The required optimum flow rates of the system per RT are ranged from 3.8 to 9.8lpm being less than the typical building loop flow of 9.5 to 11.4lpm.

Security Verification of FTP-Proxy Security Model Coloured Petri Net (컬러드 페트리 네트를 기반으로 한 FTP 프록시 보안 모델의 안전성 검증)

  • Lee, Moon-Ku;Jun, Moon-Seog
    • Journal of KIISE:Information Networking
    • /
    • v.28 no.3
    • /
    • pp.369-376
    • /
    • 2001
  • The firewall systems can be installed between the intemal network and the extemal network. The firewall systems has the least privilege, so its does not provide transparency to user. This problem of transparency can be solved by using the proxy. In this thesis, I have designed and verified the FTP-PSM(FTP-Proxy Security Mode]) which provides transparency for the firewall systems and has a strong security function. FTP-PSM doesn't finish its work after implementing a command. Instead, its does several security functions such as user authentication, MAC(MandatOlY Access Controll, DAC(Discretionary Access Controll and authentication of user group. Those data must not be lost under any circumstances in order to implement the above security functions. So, the security against such problems as falling into deadlock or unlimited loop during the implementation must be verified. Therefore, FTP-PSM suggested in thesis was verified its security through PHPlace Invariant) based on CPNlCo]oured Petri Net).

  • PDF

The estimation of river discharge by using the mean velocity equation in a unsteady condition (평균유속공식을 이용한 부정류 하천유량 산정)

  • Choo, Tai Ho;Chae, Soo Kwon;Yoon, Hyeon Cheol;Yun, Gwan Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6558-6564
    • /
    • 2013
  • As the average indicator for amount of water flowing in any cross section of a river, the mean discharge has been reported to be a very important factor for examining water circle constructions in a river basin, the design and construction of a hydraulic structure, and water front area use and management. The stage-discharge curve based on discharge and stage data measured in a normal season were basically derived. Using this derivation, the necessary discharge data was obtained. The values produced in this manner corresponded to the measured data in a uniform flow state well, but showed limited accuracy in a flood season (unsteady flow). In the present paper, the mean velocity in unsteady flow conditions, which exhibited loop form properties, was estimated using the new mean velocity formula derived from Chiu's 2-D velocity. The results of RMSE and Polar graph analyses showed that the proposed equation exhibited approximately nineteen times the accuracy compared to the Manning and Chezy equations.

Improvement and Expected Effect of Construction Supervision System for Mix-Use Residential Building (주상복합건물의 감리제도 개선방안과 기대효과)

  • Son, Bo-Sik;Bu, Seung-Hyon;Kim, Kyung-Whal;Lee, Hyun-Soo;Ryu, Han-Guk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.7 no.2 s.30
    • /
    • pp.62-70
    • /
    • 2006
  • As buildings are changing variously from the side of use, efficiency and size, the construction qualities are more importantly recognized. Supervision system was enacted in the Residential Building Law in 1990 and responsibility supervision system in the Construction Engineering Management Law in 1994, respectively. However, recently revised supervision system in 2003 has some limitations: the present problems of appointing supervisor, disposing the supervisors, supervisor's works. Therefore, the aim of this study is to improve the present supervision system for mix-use residential building. By implementing the proposed revised supervision system, it will be able to expect quality improvement, confidence of the owner and the user, development of construction technology, and increase international competitiveness of supervision company.

A Study on Incident Detection Model using Fuzzy Logic and Traffic Pattern (퍼지논리와 교통패턴을 이용한 유고검지 모형에 관한 연구)

  • Hong, Nam-Kwan;Choi, Jin-Woo;Yang, Young-Kyu
    • Journal of Korea Spatial Information System Society
    • /
    • v.9 no.1
    • /
    • pp.79-90
    • /
    • 2007
  • In this paper we proposed and implemented an incident detection model which combines fuzzy algorithm and traffic pattern in order to enhance the efficiency of incident detection for the highways with lamps. Most of the existing algorithms dealt with highways without lamps and can not be used for detecting incidents in the highways with lamps. The data used for model building are traffic volume, occupancy, and speed data. They have been collected by a loop sensor at 5 minutes interval at a point in the Internal Circular Highway of Seoul for the period of 3 months. In this model, the three parameters collected by sensor were fuzzified and combined with the daily traffic pattern of the link. The test of efficiency of the propsed model was performed by comparing the result of proposed model with traditional APID algorithm and fuzzy algorithm without the pattern data respectively. The result showed significant amount of improvement in reducing the false incident detection rate by 18%.

  • PDF

A MIMO LTE Precoding Codebook Based on Fast Diagonal Weighted Matrices (고속 대각 하중 행렬을 이용한 MIMO LTE 프리코딩 코드북)

  • Park, Ju-Yong;Peng, Bu Shi;Lee, Moon-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.3
    • /
    • pp.14-26
    • /
    • 2012
  • In this paper, a fast diagonal-weighted Jacket matrices (DWJMs) is proposed to have the orthogonal architecture. We develop the successive DWJM to reduce the computational load while factorizing the large-order DWJMs into the low-order sparse matrices with the fast algorithms. The proposed DWJM is then applied to the precoding multiple-input and multiple output (MIMO) wireless communications because of its diagonal-weighted framework with element-wise inverse characteristics. Based on the properties of the DWJM, the DWJM can be used as alternative open loop cyclic delay diversity (CDD) precoding, which has recently become part of the cellular communications systems. Performance of the DWJM-based precoding system is verified for orthogonal space-time block code (OSTBC) MIMO LTE systems.

The Condensation Heat Transfer of R-22 and R-410A in an Inner Diameter Tube of 1.77 mm (내경 1.77 mm관내 R-22와 R-410A의 응축열전달)

  • Son, Chang-Hyo;Roh, Geon-Sang
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.1
    • /
    • pp.48-53
    • /
    • 2008
  • The condensation heat transfer coefficients of R-22 and R-410A in a small diameter tube were investigated. The main components of the refrigerant loop consist of a receiver, a variable-speed pump, a mass flowmeter, an evaporator (preheater), and a condenser (test section). The test section consists of smooth, horizontal copper tube of 3.38 mm outer diameter and 1.77 mm inner diameter. The refrigerant mass fluxes varied from 450 to $1050\;kg/(m^2s)$ and the average inlet and outlet qualities were 0.05 and 0.95. The main results were summarized as follows : the condensation heat transfer coefficient also increases with increasing mass flux and quality. The condensation heat transfer coefficient of R-410A was slightly higher than that of R-22. Most of correlations proposed in the large diameter tube showed significant deviations with experimental data except for the ranges of low quality and low mass flux.

  • PDF

A Static Analyzer for Detecting Memory Leaks based on Procedural Summary (함수 요약에 기반한 메모리 누수 정적 탐지기)

  • Jung, Yung-Bum;Yi, Kwang-Keun
    • Journal of KIISE:Software and Applications
    • /
    • v.36 no.7
    • /
    • pp.590-606
    • /
    • 2009
  • We present a static analyzer that detects memory leaks in C programs. It achieves relatively high accuracy at a relatively low cost on SPEC2000 benchmarks and several open-source software packages, demonstrating its practicality and competitive edge against other reported analyzers: for a set of benchmarks totaling 1,777 KLOCs, it found 332 bugs with 47 additional false positives (a 12.4% false-positive ratio), and the average analysis speed was 720 LOC/sec. We separately analyze each procedure's memory behavior into a summary that is used in analyzing its call sites. Each procedural summary is parameterized by the procedure's call context so that it can be instantiated at different call sites. What information to capture in each procedural summary has been carefully tuned so that the summary should not lose any common memory-leak-related behaviors in real-world C program. Because each procedure is summarized by conventional fixpoint iteration over the abstract semantics ('a la abstract interpretation), the analyzer naturally handles arbitrary call cycles from direct or indirect recursive calls.

The Effects of Distal Sinus on the Hydrodynamic Performance of the Prosthetic Heart Valves (인공판막 후부 공동부가 판막의 수력학적 성능에 미치는 영향)

  • 이계한;서종천
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.297-303
    • /
    • 1998
  • The sinus distal to the prosthetic heart valve influences the valve closure behavior and velocity field near the valve, therefore affects the hydrodynamic performance of the prosthetic heart valve. In order to study the effects of valve distal geometry on the hydrodynamic performance of the prosthetic valves, mechanical bileaflet valve(SJMV), monoleaflet polymer valve(MLPV) and trileaflet polymer valve(FTPV) are inserted in the test sections which have the straight and the sinus shape distal to the valve. Leakage volumes and systolic mean pressure drops are measured in the pulsatile mock circulation flow loop. Leakage volumes are slightly less and systolic mean pressure drops are higher in the sinus test section comparing to those in the straight test section, but the differences are statistically insignificant. Flow waveforms are analyzed in order to predict the valve closure behavior. The distal sinus does not affect the closure of the MLPV, but early valve closure of SJMV is observed in the sinus test section. This effect is more significant in FTPV, and the reverse flow peak of FTPV is reduced in the sinus test section. Therefore the sinus distal to the valve can reduce the reverse flow jet caused by sudden valve closure.

  • PDF