• Title/Summary/Keyword: 순환유동층

Search Result 275, Processing Time 0.025 seconds

Research on the Replacement of Bed Material and Multifunctional Additives in Circulating Fluidized Bed Combustion Using Solid Fuels (고형연료사용 순환유동층 연소로에서의 유동사 대체 및 다기능성 첨가제에 관한 연구)

  • Park, In su;Nam, Jeong soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.115-116
    • /
    • 2023
  • In this study, it was confirmed whether kaolin can play a role as a bed materials and a role in reducing clinkers by using kaolin with a bed materials for the purpose of removing clinkers such as slagging and fouling generated in circulating fluidized bed combustion furnaces using solid fuel.

  • PDF

Effect of equivalence ratio on operation of 3MWth circulating fluidized bed for biomass gasification (3MWth급 순환유동층 바이오매스 가스화기의 운전에서 Equivalence ratio 영향)

  • Park, Seongbum;Lee, Jeoungwoo;Song, Jaehun;Pak, Daewon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.58-65
    • /
    • 2017
  • Fluidized bed gasification is technically and economically proven technology, which shows the high possibility of realization and commercialization. However, in Korea, development of FBG to the commercial scale for power generation and industry is mainly blocked by the fact that there is no experience of design, troubleshooting and operation of even pilot scale fluidized bed gasifier. In this study, a $3MW_{th}$ circulating fluidized bed(CFB) was newly developed for biomass gasification. The fluidized bed was mainly composed of circulating and bubbling fluidized reactors integrating in-situ tar removal step in the system. For cleaning of the tar and acid gas in the product gas, the sequential gas cleaning process comprised of a ceramic filter, rapid quencher and wet scrubber was adopted. Effect of equivalence ratio was investigated to find the optimal operating conditions for the $3MW_{th}$ integrated system of fluidized bed gasification.

Axial Solid Holdup in a Circulating Fluidized Bed Plasma Reactor under Reduced Pressure (감압 순환유동층 플라즈마 반응기의 축방향 고체체류량)

  • Park, Sounghee
    • Korean Chemical Engineering Research
    • /
    • v.54 no.4
    • /
    • pp.527-532
    • /
    • 2016
  • The effects of gas velocity and solid circulation rate on the axial solid holdup distribution have been determined in a 10 mm-I.D. ${\times}$ 800 mm-high circulating fluidized bed plasma reactor under reduced pressure (1torr). Polystyrene polymer powder and nitrogen gas are used as solid and gas materials respectively. The change of solid circulation rate by a large gas flow rate of the riser (40~80 sccm) is also possible by a relatively small gas flow rate of the solid recirculation part (6.6~9.9 sccm). The solid circulation rate in the reactor under reduced pressure increases with increasing aeration velocity in the solid recirculation part. The axial solid holdup in the riser decreases from the dense at the bottom to the dilute phase at the top section of the riser. Solid holdups at the axial positions in the riser increase linearly with increasing solid circulating velocity. From these results, we could determine the position of plasma load for good plasma ignition, maintain and plasma reaction.

A Study on Gas Mixing in a Circulating Fluidized Bed (순환유동층에서 기체의 혼합특성에 관한 연구)

  • 남궁원;김상돈
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.11a
    • /
    • pp.23-26
    • /
    • 1995
  • 내경 0.1 m, 높이 5.3 m 의 순환유동층 반응기를 사용하여 기체의 역혼합특성을 조사하였다. 기체의 역혼합은 동일한 기상유속일때 고체순환속도가 증가할수록 증가하였다. 희박상영역에서 일정한 고체체류량에서는 기상유속이 증가할수록 벽면에서의 하강흐름도 증가되어 기체의 역혼합은 증가되었다. Tracer 주입위치가 반응기 벽면에서 중심으로 이동할수록 빠른 기체와 고체의 흐름으로 인하여 기체의 역혼합은 상당히 감소하였다. 그리고, 희박상영역에서 core-annulus 구조를 기초로 하여 기체역혼합과 core 와 annulus 간의 물질전달계수를 예측할 수 있는 모델식을 제안하였다.

  • PDF

Conceptual Design of 50 kW thermal Chemical-Looping Combustor and Analysis of Variables (열량기준 50kW급 매체순환식 가스연소기의 개념설계 및 변수해석)

  • 류호정;진경태
    • Journal of Energy Engineering
    • /
    • v.12 no.4
    • /
    • pp.289-301
    • /
    • 2003
  • To develop a chemical-looping combustion technology, conceptual design of 50 kW thermal chemical-looping combustor, which is composed of two interconnected pressurized circulating fluidized beds, was performed by means of mass and energy balance calculations. A riser type fast fluidized bed was selected as an oxidizer and a bubbling fluidized bed was selected as a reducer by mass balance for the chemical-looping combustor. Calculated values of bed mass, solid circulation flux, and reactor dimension by mass and energy balance calculations were suitable for construction and operation of chemical-looping combustor. It is concluded from the comparison of the design results and operating values of commercial circulating fluidized bed that the process outline is realistic. Moreover, the previous results support that oxygen carrier particle, NiO/bentonite, fulfills the conversion rates needed for the proposed design. The effects of system capacity, metal oxide content in a oxygen carrier particle, amount of steam input, gas velocity, and solid depth on design values were investigated and the changes in the system performance can be estimated by proposed design tool.

Reaction Characteristics of Oxygen Carrier Perticle for Chemical-Looping Combustor in Fixed Bed and Pressurized Fluidized Bed (고정층과 가압유동층에서 매체순환식 가스연소기 산소공여입자의 반응특성)

  • 류호정;배달희;진경태
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.05a
    • /
    • pp.173-177
    • /
    • 2002
  • 두 개의 유동층 사이를 순환하는 금속매체(Metal or Metal oxide)를 이용하여 공기에 의한 금속매체의 산화와 기체연료(H$_2$, CO, CH$_4$등)에 의한 금속산화물의 환원반응이 별개의 반응기에서 일어나게 하는 새로운 개념의 연소기술인 매체순환식 가스연소기술은 공기와 기체연료를 직접 접촉시켜 반응하는 기존의 가스연소기에 비해 많은 장점을 가지고 있다.(중략)

  • PDF

A Study on Two-interconnected Fluidized Beds System for Selective Solid Circulation (선택적 고체순환을 위한 2탑 유동층 시스템 연구)

  • Ryu, Ho-Jung;Jang, Myoung-Su;Kim, Hong-Ki;Lee, Dong-Kyu
    • Korean Chemical Engineering Research
    • /
    • v.47 no.3
    • /
    • pp.337-343
    • /
    • 2009
  • To apply to novel two-interconnected fluidized beds system for selective solid circulation, a solid separator and a solid circulation system were developed. The solid separation rate increased as the gas velocity through the solid injection nozzle, solid height, and diameter of solid injection nozzle increased. However, the effect of the fluidization velocity was negligible. Coarse($212{\sim}300{\mu}m$) and fine($63{\sim}106{\mu}m$) particles were separated using the solid separator and the solid separation rate was ranged from 66 to 453 g/min. The solid circulation rate increased as the gas velocity through the solid injection nozzle, solid height, and the number of solid intake holes increased. However, the effect of the fluidization velocity was negligible. Fine particle was circulated using the solid circulation system and the solid circulation rate was ranged from 65 to 390 g/min. We also proposed two interconnenced fluidized beds system for selective solid circulation equipped with the developed solid separator and the solid circulation system. Long-term operation of continuous solid circulation up to 20 hours has been performed to check feasibility of stable operation. The pressure drop profiles in two beds and the solid separation rate were maintained steadily, and therefore, we could conclude that solid circulation was smooth and stable.

Reaction Characteristics of Desulfurization and Reduction of Calcium Oxide in a Circulating Fluidized Bed (순환유동층에서 석회석에 의한 탈황과 환원반응 특성)

  • 배달희;류호정;선도원;이창근;손재익;이동규
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.05a
    • /
    • pp.219-222
    • /
    • 2002
  • 석탄연소 순환유동층 연소로에서 석회석을 이용한 SO$_2$의 제거는 이미 기술적으로 입증된 방법이다. 연소로에 투입된 석회석은 식(1)과 같은 소성반응을 거친 후 CaO로 변화하며 식(2)와 같은 황화(sulfation)반응에 의해 SO$_2$를 흡수하여 CaSO$_4$ 형태로 변화한다.(중략)

  • PDF

A Study on Dioxin Reduction Characteristics of Rapid Cooling Type Circulating Fluidized Bed Heat Exchanger (급속냉각형 순환유동층 열교환기의 다이옥신 저감성능 연구)

  • Park, Sang-il
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1231-1236
    • /
    • 2008
  • The flow and heat transfer performance were measured at high temperatures in CFB heat exchanger with multiple risers and downcomers. The theoretical model for predicting heat exchanger performance was developed in this study. The model predictions were compared with the measured heat transfer rates to show relatively good agreement. The maximum gas cooling rate was $20,300^{\circ}C/sec$, and the dioxin reduction rate was 68%.

  • PDF

초임계압 유동층보일러 2대, 1,000MW 증기터빈 조합 신개념 발전 플랜트 소개

  • Kim, Hyeon-Cheol
    • Journal of the KSME
    • /
    • v.56 no.10
    • /
    • pp.44-48
    • /
    • 2016
  • 에너지 생태계의 급변하는 환경속에 고효율, 대용량, 연료 유연성을 확보하기 위한 새로운 도전이 펼쳐지고 있다. 이 글에서는 세계 최대, 최초 초임계 순환유동층 보일러 2대와 1,000MW 증기터빈을 조합한 신개념 설계의 2개 호기(2,000MW) 건설, 한국남부발전(주) 삼척그린파워를 중심으로 내용을 기술하고자 한다.

  • PDF