• Title/Summary/Keyword: 순상대효과

Search Result 2, Processing Time 0.014 seconds

Characteristic Analysis of Industrial Structure in Jeju Special Self-Governing Province Using Dynamic Shift-Share Analysis (동태적 변이할당분석을 이용한 제주특별자치도 산업구조 특성 분석)

  • Yang, Young-Jun
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.8
    • /
    • pp.181-193
    • /
    • 2019
  • The regional economy growth of Jeju has seen higher than national growth since 2011 by the establishment of Jeju Special Self-Governing Province and the increase of incoming population, but its economic growth has slowed after 2016. This study conducted the dynamic shift-share analysis using the production and employees of each industry from 2010 to 2016, targeting Jeju with many factors of regional economic change. In the results of empirical analysis, the regional economy of Jeju was not the industrial structure depending on the national growth, but the industrial structure by the competitiveness and industrial structure of Jeju region. The industries having positive(+) effects of industrial mix effect and competitive effect on the production and the number of employees were the electricity/gas/heavy equipments & waterworks, construction, accommodation & restaurants, and service industry. These industries have positive effects on the regional industry of Jeju. The above-mentioned industries are not only more likely to grow than other regions, but also to drive the local economy of Jeju. In order for these industries to continuously contribute to the regional economy of Jeju, it would be necessary to have the policy/institutional support in the long-term perspective.

The Comparison of Image Quality and Quantitative Indices by Wide Beam Reconstruction Method and Filtered Back Projection Method in Tl-201 Myocardial Perfusion SPECT (Tl-201 심근관류 SPECT 검사에서 광대역 재구성(Wide Beam Reconstruction: WBR) 방법과 여과 후 역투영법에 따른 영상의 질 및 정량적 지표 값 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Shim, Dong-Oh;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.122-127
    • /
    • 2010
  • Purpose: The Xpress3.$cardiac^{TM}$ which is a kind of wide beam reconstruction (WBR) method developed by UltraSPECT (Haifa, Israel) enables the acquisition of at quarter time while maintaining image quality. The purpose of this study is to investigate the usefulness of WBR method for decreasing scan times and to compare to it with filtered back projection (FBP), which is the method routinely used. Materials and Methods: Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on an equality with counts from patient's body. The Tl-201 concentrations in the compartments were 74 kBq (2 ${\mu}Ci$)/cc in myocardium, 11.1 kBq (0.3 ${\mu}Ci$)/cc in soft tissue, and 2.59 kBq (0.07 ${\mu}Ci$)/cc in lung. The non-gated Tl-201 myocardial perfusion SPECT data were acquired with the phantom. The former study was scanned for 50 seconds per frame with FBP method, and the latter study was acquired for 13 seconds per frame with WBR method. Using the Xeleris ver. 2.0551, full width at half maximum (FWHM) and average image contrast were compared. In clinical studies, we analyzed the 30 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center from January to April 2010. The patients were imaged at full time (50 second per frame) with FBP algorithm and again quarter-time (13 second per frame) with the WBR algorithm. Using the 4D MSPECT (4DM), Quantitative Perfusion SPECT (QPS), and Quantitative Gated SPECT (QGS) software, the summed stress score (SSS), summed rest score (SRS), summed difference score, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were analyzed for their correlations and statistical comparison by paired t-test. Results: As a result of the phantom study, the WBR method improved FWHM more than about 30% compared with FBP method (WBR data 5.47 mm, FBP data 7.07 mm). And the WBR method's average image contrast was also higher than FBP method's. However, in result of quantitative indices, SSS, SDS, SRS, EDV, ESV, EF, there were statistically significant differences from WBR and FBP(p<0.01). In the correlation of SSS, SDS, SRS, there were significant differences for WBR and FBP (0.18, 0.34, 0.08). But EDV, ESV, EF showed good correlation with WBR and FBP (0.88, 0.89, 0.71). Conclusion: From phantom study results, we confirmed that the WBR method reduces an acquisition time while improving an image quality compared with FBP method. However, we should consider significant differences in quantitative indices. And it needs to take an evaluation test to apply clinical study to find a cause of differences out between phantom and clinical results.

  • PDF