• Title/Summary/Keyword: 수평 급기

Search Result 4, Processing Time 0.023 seconds

Study on the Optimal Velocity of Horizontal Air Jet of a Range hood system (주방용 후드 수평급기의 최적속도 결정에 관한 연구)

  • Kim, Sang-Gyu;Park, Sung-Geun;Yong, Ho-Taek;Kim, Dong-Yoon;Choi, Hyoung-Gwon
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.63-68
    • /
    • 2005
  • In the present paper, the study on the optimal horizontal air jet velocity of a range hood system has been studied by three dimensional numerical simulation. It has been shown that the air jet of a range flood system generates coanda effect confining the contaminated (high temperature) air in a certain region while the jet pushes out more contaminated air into a room as the jet velocity increases. Therefore, the optimal jet velocity has been determined by the combination of the two mechanism.

  • PDF

Horizontal Air-Jet Effect on the Natural Convection around a Range-Hood System (수평 급기가 레인지 후드 주위의 자연대류에 미치는 영향)

  • Kim Byoung Guk;Choi Hyoung Gwon;Yong Ho Taek;Lee Myeong Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.333-340
    • /
    • 2005
  • Horizontal air-jet effect has been utilized in some air conditioning systems in order to control the contaminated air indoor. In the present study, the flow and heat transfer of the contaminated air from a range hood system has been investigated with or without horizontal air-jet effect when the hood fan is on or off. For the present numerical experiment, PAT Flow code has been used. From the present numerical simulations, it has been shown that the air jet of a range hood generates coanda effect confining the contaminated air in a certain region. Furthermore, the qualitative relation between the flow rate of the capture air jet and the distribution pattern of the contamination has been discussed.

Characteristices of Temperature Distribution in a Closed Space with Heat Source and Porous Horizontal Partition (유공성 수평격판을 가진 열원이 있는 밀폐공간내의 온도분포 특성)

  • Park, Chan-Su;Cho, Dae-Hwan;Jeon, Cheol-Kyun
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.3B
    • /
    • pp.29-37
    • /
    • 1999
  • Ventilation of the marine engine room is very important for the health of the workers as well as the normal operation of machines. To find proper ventilation conditions of this engine room, numerical simulation with standard k-${\epsilon}$ model was carried out. In the present study, the marine engine room is separated to two floors with porus horizontal partition and considered as a closed space with a heat source and forced ventilation ducts. The porosity of horizontal partition is found to be important. For the engine room with 2 supply ports & 2 exhaust ports, the increasing of the porosity of horizontal partition is effective to reduce the recirculation flow zone in the second floor. When the engine room is ventilated with three supply air ports & one exhaust port, the increasing of the porosity of horizontal partition is effective to reduce the recirculating flow zone in the exhaust air area, but there is a possibility of local extreme heating at the lower side of engine near bottom.

  • PDF

Fire Modeling and Smoking Control Characteristic Analysis of Electric Room by Using FDS (FDS를 이용한 전기실의 화재모델링 및 연기제어 특성 분석)

  • Choi, Jeong-A;Lee, Min-Gu;Lee, Dae-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.662-668
    • /
    • 2018
  • Most electric rooms are located in the underground spaces of buildings. When a fire occurs in electrical equipment, the fire expands to cable insulation material, resulting in toxic smoke and combustion products. If the smoke and combustion products quickly move vertically and horizontally, the evacuation of occupants and firefighting activities will be hindered. Therefore, it is necessary to design optimal equipment for smoke control in cases of fires in electric rooms. This study analyzes the characteristics of smoke and combustion products in fires in a cubicle-type switchboard in an electric room using PyroSim, which is based on the program Fire Dynamics Simulator (FDS). The fire modeling consists of four scenarios according to the operation mode of the mechanical ventilation equipment, the amount of air supply and exhaust, and the location of the air supply slot. The analysis shows that the mechanical ventilation equipment improves the smoke density, visibility, carbon monoxide concentration, and temperature characteristics. The visibility and temperature characteristics were improved when the air flow rate and the location of the air supply slot from fire defense regulations were applied.