• Title/Summary/Keyword: 수평사위

Search Result 33, Processing Time 0.018 seconds

Research About Students' Horizontal Heterophoria in Near Distance with Maddox Rod (Maddox Rod를 사용한 대학생의 근거리 수평사위에 대한 고찰)

  • Choi, Kyong-Seo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.59-63
    • /
    • 2009
  • Purpose: To investigate the near horizontal heterophoria of the college students in their twenties on north Kyonggi Province. Methods: The all subjects had not experienced any ocular surgery and have no disease and their mean age is 22.9. As 122 subjects, they are 50 emmetropes and 72 ametropes. The ametropes are all myopia. After distance visual acuity correction with subjective and objective refraction test, evaluated their horizontal heterophoria with red maddox rod. Results: In maddox rod test, the subjects consist of orthophoria 4.9%, esophoria 9.8% and exophoria 85.3%. In the emmetropes orthophoria is 8%, esophoria is also 8% and exophoria is 84%. In the ametropes orthophoria is 2.8%, esophoria is 11.1% and exophoria is 86.1%. The mean size of horizontal heterophoria is esophoria 3.59PD (prism diopter), exophoria 7.04PD and in the emmetropes esophoria is 3.25PD, exophoria is 6.60PD. In the ametropes esophoria is 3.75PD and exophoria is 7.34PD. Conclusions: In the emmetropoes the orthophoria is more than in the ametropes and the esophoria and exophoria is more in the ametropes. But the differences between the heterophoria and emmetropia or ametropia were not significant (p>0.05). The mean size of heterophoria is higher in the ametropes than in the emmetropoes. The distribution range of heterophoria is wider in the male subjects than the female subjects.

  • PDF

A study on the distance and near horizontal phoria of the young people in Korea (한국 청년의 원거리와 근거리 수평사위에 관한 연구)

  • Kim, Hye-Dong;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.251-255
    • /
    • 2004
  • Our research is about the measurement of the distance & near horizontal phoria by the Von Graefe test. The inspection was processed about normal 60 subjects(120eyes) aged from 20 to 30) years old by the subjective method of refraction. Among 120 eyes, the myopia is 64eyes(53%) and the emmetropia is 56eyes(47%). In the measurement of the distance horizontal phoria, we could know that the exophoria is 40%(24 subjects), the esophoria is 40%(24 subjects), and the orthophoria is 20%(12 subjects). In case of the near horizontal phoria, we could know that the exophoria is 65%(39 subjects), the esophoria is 23.3%(14 subjects), and the orthophoria is 11.7%(7 subjects).

  • PDF

Analysis of far & near distance of lateral phoria by various testing methods (검사 방법에 따른 원·근거리 수평사위의 분석)

  • Hong, Dong-Gyun;Jung, Han-Sub;Park, Sang-An
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.423-430
    • /
    • 2004
  • This Study on three different methods which are Von Graefe test, Maddox Rod test and Howell card test of measuring far and near lateral phoria investigated. It reviewed that 420 subjects aged from 15 to 35 years old. The result were as follows; 1. Using Von Graefe lateral phoria measurement, they were measured 6% for orthophoria, 62% for exophoria, 32% for esophoria at far distance. 2. Using Von Graefe lateral phoria measurement, they were measured 2% for orthophoria, 74% for exophoria, 24% for esophoria at near distance. 3. Using Maddox Rod lateral phoria measurement, they 59% for exophoria, 37% for esophoria at far distance. 4. Using Maddox Rod lateral phoria measurement, they 67% for exophoria, 30% for esophoria at near distance. 5. Using Howell card lateral phoria measurement, they 60% for exophoria, 32% for esophoria at far distance. 6. Using Howell card lateral phoria measurement, they 69% for exophoria, 27% for esophoria at near distance.

  • PDF

A study on the measurement and tendency of heterophoria using Von Graefe test and Maddox rod test (프리즘 분리법과 마독스 로드 검사법을 이용한 사위측정과 경향 연구)

  • Oh, Hyun-Jin;Doo, Ha-Young;Oh, Seung-Jin
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.485-491
    • /
    • 2012
  • To investigate the difference in the value of horizontal heterophoria measured in phoria test of about normal 72 college students, using both Von Graefe test and Maddox rod test. We used two different methods which are Von Graefe test and Maddox rod test on full correction condition at the long distance. Using Von Graefe test of horizontal heterophoria Measurement, We measured 21 patients(29%) for orthophoria, 36 patients(50%) for exophoria and 15 patients(21%) for esophoria at distance. Using Maddox rod test of horizontal heterophoria Measurement, We measured 36 patients(50%) for orthophoria, 26 patients(36%) for exophoria and 10 patients(14%) for esophoria at distance. Each test average were $0.93{\Delta}$ BI for Von Graefe test, $0.96{\Delta}$ BI for Maddox rod test. We could not find the definite difference about the value of horizontal heterophoria aby testing method. Furthermore, heterphoria AC/A ratio was found to vary from 1.0 to 8.8 and its relationship to refractive error could not be determined.

Head Posture-Induced Phoria Deviation (머리 위치에 따른 사위도의 변화)

  • Ha, Eun-Mi;Son, Jeong-Sik;Moon, Byeong-Yeon;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.155-160
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate how phoria variations would vary with head positions, as well as to review the need to differentiate prism placement over either eye in a relation to the imbalance of the extraocular muscle. Methods: This study was carried out with 44 males (88 eyes) and 16 females (32 eyes) aged between 20 and 30. For all subjects, testings were performed using cover test, subjective refraction, phoria and vergence test. To analyze phoria variations comparatively for the head tilt test and the face turn test, phoria deviation were measured using the von Graefe. Results: For the phoria variation related with head tilt and face turn, a significant difference was observed in the group judged to be abnormal on the horizontal phoria of Morgan' norm (p<0.05); especially in patients who needed near prescription of Sheard's criterion, a higher variation was observed (p<0.05). The abnormal group was composed of patients who needed distance prescription of Sheard's criterion and ones who did not need the prescription, all of whom showed phoria variations, but the mean value was less than the near. Conclusions: With regard to the head tilt and face turn related phoria level, the patients who needed near horizontal prism prescription of Sheard's criterion showed a remarkably higher variation. Altogether, it is deemed to check whether extraocular muscles are ill-balanced in both eyes previously to determine the prism power on phoria level to the end that each of prism powers may be accurately determined.

A Study About N.P.C, Heterophoria and Near Convergence and Divergence by Amount of the Refractive Errors (굴절이상도에 따른 폭주근점과 근거리 수평사위, 폭주 및 개산 여력의 연구)

  • Choi, Sun-Mi
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.53-57
    • /
    • 2009
  • Purpose: To study the relationship of N.P.C, heterophoria and near convergence and divergence by amount of the refractive error. Methods: All subjects have no ocular disease and their mean age is 22.7. All 39 subjects examined about refractive error, near point of convergence (NPC), heterophoria, near convergence and divergence. Results: Classified by low refractive state, middle refractive state, and high refractive state compared with the expected value of Morgan. NPC had been measured within low and middle refractive state eight all the 8cm. However, high refractive state measured 9.64 cm. Low and middle refractive state for the classification by near phoria. Near esophoria groups was smallest by near divergence and exophoria groups was smallest by near convergence. Conclusions: Near convergence were largest with esophoria while near divergence were largest with exophoria.

  • PDF

Comparison of three different methods of measuring horizontal phoria and vertical phoria (검사방법에 따른 수평·수직사위량의 비교)

  • Kim, Hye-Dong;Kim, Dae-Nyoun;Park, Eun-Kyeu
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.13-18
    • /
    • 2003
  • We did the comparison research about three different methods of measuring horizontal phoria and vertical phoria which are Von Graefe test, Maddox Rod test and polarizing lens test. The inspection was don with the subjective method of refraction about normal 63 subjects aged from 20 to 28 years old. The analysis of date resulted in as follows : 1. Using Von Graefe Horizontal phoria Measurement, they were measured 5% for orthpharia, 51% for exophoria and 44% for esophoria. 2. Using Von Graefe vertical phoria Measurement, they were measured 68% for orthphoria, 20% for left hypophoria against the right and 12% for left hyperphoria against the right. 3. Using Maddox Rod Horizontal phoria Measurement, they were measured 7% for orthphoria, 49% for exophoria and 44% for esophoria. 4. Using Maddox Rod vertical phoria Measurement, they were measured 70% for orthphoria, 19% for left hypophoria against the right and 11% for left hyperphoria against the right. 5. Using Polarizing Horizontal phoria Measurement, they were measured 10% for orthphoria, 49% for exophoria and 41% for esophoria. 6. Using Polarizing vertical phoria Measurement, they were measured 92% for orthpharia, 5% for left hypophoria against the right and 3% for left hyperphoria against the right.

  • PDF

A Study on the Phoria of Korean Male and Female Adults (한국인 성인 남녀의 사위에 관한 연구)

  • Sung, Duk Yong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.59-63
    • /
    • 2001
  • Once refractive error of the eye was fully corrected. Polarization Test was used to investigate binocular vision function. As the results of phoria measurement of Korean adults for 53males and 59 females, orthophoria in 27.68%, esophoria in 12.50%, exophoria in 48.21%, verical phoria in 3.75%, esophoria(+verical phoria) in 2.68%, and exophoria(+vertical phoria) in 5.36%, respectively. Horizontal phoria is below $3{\Delta}$ mostly and verical phoria is below $1{\Delta}$.

  • PDF

Investigation of the horizontal heterophoria measurement at distance by various testing method (사위검사 방법의 차이에 따른 원거리 수평사위 검사값 비교)

  • Sim, Hyun-Seog;Lee, Seang-Wook;Jang, Seong-Joo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.155-160
    • /
    • 2001
  • To investigate the subjective refractive error with Von Graefe test. Maddox Rod test and polarizing lens test of Horizontal Heterophoria Measurement at distance on normal 109 subjects aged from 18 to 30 years old. The results were as follows: 1. Using Von Graefe Horizontal Heterophoria Measurement, they were measured 15% for orthophoria, 65% for exophoria and 20% for esophoria at distance. 2. Using Maddox Rod Horizontal Heterophoria Measurement, they were measured 14% for orthophoria, 57% for exophoria and 29% for esophoria at distance. 3. Using polarizing lens test of Horizontal Heterophoria Measurement, they were measured 15% for orthophoria, 72% for exophoria and 13% for esophoria at distance. 4. Each test average were $1.32{\Delta}BI$ for Von Graefe test, $0.88{\Delta}BI$ for Maddox Rod test and $1.76{\Delta}BI$ for polarizing lens test. 5. Patient's preference distribution were 44% for Von Graefe test, 28% for Maddox Rod test and 28% for polarizing lens test.

  • PDF

A Study on The Measurement and Tendency of Horizontal Heterophoria Using Von Graefe Method (Von graefe법을 이용한 사위의 측정과 경향에 관한 연구)

  • Lee, Ki-Seok;Jung, Mi-Boon;Kim, Tae-Hun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.2
    • /
    • pp.151-157
    • /
    • 2006
  • We researched distant & near horizontal heterophoria of myope using von graefe method on full correction condition for young people 49 subjects(98eyes) with myopia after testing the objective refraction. Among the whole subjects, we got the results as Orthophoria 51.00%, Exophoria 38.75%, Esophoria 10.25% and Heterophoria 49.00% at a long distant. At a short distant, they showed Orthophoria 22.45%, Exophoria 67.35, Esophoria 10.20%, and Heterophoria 77.55%, Orthophoria 22.45. At a long distant they showed Orthophoria 4.08%, Exophoria 8.16%, Esophoria 0% on high myopia, Orthophoria 18.37%, Exophoria 12.25%, Esophoria 0% on middle myopia and Orthophoria 28.57%, Exophoria 18.37%, Esophoria 10.20% on low myopia.

  • PDF