• Title/Summary/Keyword: 수직 접합부

Search Result 107, Processing Time 0.025 seconds

A novel TIGBT tructure with improved electrical characteristics (향상된 전기적 특성을 갖는 트렌치 게이트형 절연 게이트 바이폴라 트랜지스터에 관한 연구)

  • Koo, Yong-Seo;Son, Jung-Man
    • Journal of IKEEE
    • /
    • v.11 no.4
    • /
    • pp.158-164
    • /
    • 2007
  • In this study, three types of a novel Trench IGBTs(Insulated Gate Bipolar Transistor) are proposed. The first structure has P-collector which is isolated by $SiO_2$ layer to enhance anode-injection-efficiency and enable the device to have a low on-state voltage drop(Von). And the second structure has convex P-base region between both gates. This structure may be effective to distributes electric-field crowded to gate edge. So this structure can have higher breakdown voltage(BV) than conventional trench-type IGBT(TIGBT). The process and device simulation results show improved on-state, breakdown and switching characteristics in each structure. The first one was presented lower on state voltage drop(2.1V) than that of conventional one(2.4V). Also, second structurehas higher breakdown voltage(1220V) and faster turn off time(9ns) than that of conventional structure. Finally, the last one of the proposed structure has combined the two structure (the first one and second one). This structure has superior electric characteristics than conventional structure about forward voltage drop and blocking capability, turnoff characteristics.

  • PDF

Stress Analysis and Fatigue Failure of Prefabricated and Customized Abutments of Dental Implants (치과 임플란트에서 기성 지대주와 맞춤형 지대주의 응력분석 및 피로파절에 관한 연구)

  • Kim, Hee-Eun;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.209-223
    • /
    • 2013
  • This study was to evaluate the stress distributions of prefabricated, customized abutments and fixtures according to their material and shape by three-dimensional finite element analysis. And to investigate the fatigue life and fracture characteristics. Mandibular models were fabricated by reconstruction of the CT scan of patients with normal occlusion. A total of six finite element models were designed, a load of 100 N was applied on the buccal cusps vertically, and 30 degree obliquely. 10 specimens each were fabricated for the more clinically widely used 4 type abutments and were loaded according to ISO 14801. Differences in stress distribution patterns were not found according to the materials of the abutments and fixtures. But a slight difference in the stress level was detected. Customized abutment groups showed lower crown stress levels. One-piece zirconia implant showed the lowest bone stress levels. In the fatigue test, highest values were measured in group 7. Prefabricated abutments showed less variation of fatigue life (P<0.05). Use of customized abutments can improve the fracture resistance of restorations. Especially, use of customized zirconia abutments reinforced by titanium screw connecting parts is recommended.

PERIODONTAL RESPONSE FOLLOWING APPLICATION OF INTRUSIVE FORCES TO THE INCISORS WITH BONE LOSS AND PERIODONTAL DISEASE IN ADULT DOGS (골결손과 치주질환 유도 후 성견 절치의 실험적 함입이동시 치주조직의 반응)

  • Hwang, Hyeon-Shik;Park, Yang-Soo;Choi, Hong-Ran
    • The korean journal of orthodontics
    • /
    • v.28 no.3 s.68
    • /
    • pp.431-440
    • /
    • 1998
  • While periodontal disease results in the extrusion of upper incisors with interdental spacing in adult patient, the intrusive movement should be executed for the rehabilitation in terms of esthetics and function. The present study was peformed to investigate the periodontal response following orthodontic intrusion of teeth with infrabony pocket. Bone defect and periodontal disease were produced adjacent to the both maxillary second lateral incisors in four adult dogs. Four weeks later, a flap operation was performed to eliminate inflammation and a reference notch was made on the root surface at the level of bottom of each defect. Two weeks after periodontal surgery, 4 weeks of intrusion and subsequent another 4 weeks of retention was executed on the right side of incisors while left incisors served as the control. Through the histologic analysis, following results were obtained. 1. Histologic section of control side showed the reduction of pocket depth after flap operation. However, the status of long junctional epithelium was observed while new connective tissue attachment occurred in a small area adjacent newly formed cementum 2. Epithelial attachment was less around the intruded incisor while new connective tissue attachment was much more compared to the control side. 3. Plenty of cells were observed in the connective tissue around the reference notch of the intruded incisor and the degree of the new cementum formation was higher in the intruded incisor than the control. The results of the present study suggested that an orthodontic intrusion of periodontally involved and extruded incisors could be carried out with a desirable periodontal response, provided that inflammation is under control.

  • PDF

Analysis of the Characteristics of the Seismic source and the Wave Propagation Parameters in the region of the Southeastern Korean Peninsula (한반도 남동부 지진의 지각매질 특성 및 지진원 특성 변수 연구)

  • Kim, Jun-Kyoung;Kang, Ik-Bum
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.2 no.1 s.4
    • /
    • pp.135-141
    • /
    • 2002
  • Both non-linear damping values of the deep and shallow crustal materials and seismic source parameters are found from the observed near-field seismic ground motions at the South-eastern Korean Peninsula. The non-linear numerical algorithm applied in this study is Levenberg-Marquadet method. All the 25 sets of horizontal ground motions (east-west and north-south components at each seismic station) from 3 events (micro to macro scale) were used for the analysis of damping values and source parameters. The non-linear damping values of the deep and shallow crustal materials were found to be more similar to those of the region of the Western United States. The seismic source parameters found from this study also showed that the resultant stress drop values are relatively low compared to those of the Western United Sates. Consequently, comparisons of the various seismic parameters from this study and those of the United States Seismo-tectonic data suggest that the seismo-tectonic characteristics of the South eastern Korean Peninsula is more similar to those of the Western U.S.

The effect of horizontal microgap location on the bone loss around 2-piece implants (2-piece 임플란트에서 미세 간극의 수평적 위치 변화에 따른 골 소실 비교 연구)

  • Kim, Jae-Il;Lee, Yong-Moo;Yang, Byoung-Keon;Ku, Young;Chung, Chong-Pyoung;Han, Soo-Boo;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.1
    • /
    • pp.83-91
    • /
    • 2004
  • 2-piece 임플란트에서는 초기 치유 기간 동안 0.9-1.6mm의 골 소실이 일어나는데 2-piece 임플란트의 미세 간극과 그에 따른 생물학적 폭경의 형성이 중요한 원인이다. 최근 수직적으로 미세 간극의 위치를 변화시킴으로 골 소실의 양을 줄일 수 있다는 보고가 있다. 이번 실험의 목적은 미세 간극의 수평적 위치 변화에 따른 골 소실의 양을 비교하는데 있다. 하악에서 인접하여 최소 2개의 임플란트를 식립할 수 있는 7 무치악 부위에 총 15개의 Osseotitie XP 4/5를 식립하였다. 이때 임플란트의 상연이 주위 치조골과 일치하게 식립하였고 무작위로 선택하여 한 그룹(W군)에서는 wide diameter healing abutment를 연결하였고 다른 한 그룹(S 군)에서는 standard diameter healing abutment를 연결하였다. 3개월의 치유 기간후 보철 과정을 시작하였으며 이 때 healing abutment와 같은 크기의 prosthetic component를 이용하였다. 임플란트 식립 직후, 3개월의 치유 기간이 지난 보철 직전(Interval I)에, 보철 과정 직후(Interval II)에 각각 치근단 방사선 사진을 찍어 각 단계에서의 골 소실 양을 비교하였다. W 군의 경우 골 소실의 양이 Interval I에서 $1.60{\pm}0.78$, Interval I+II에서 $2.36{\pm}0.29$이었고 S 군에서는 Interval I에서 $1.5810{\pm}0.3030$, Interval I+II에서는 $1.7346{\pm}0.4199$이었다. W군에서는 Interval I와 I+II에서의 골 소실 양이 통계학적으로 유의할 만한 차이를 보였으며, Interval I+II에서의 W 군과 S 군에서의 골 소실 양도 통계학적으로 유의할 만한 차이를 나타내었다. Interval I에서는 두 그룹에서 골 소실의 차이가 없었는데 이는 1 stage surgery시 healing abutment 주위로 mucoperiosteal flap 접합의 어려움 때문으로 생각된다. 한편 Interval II에서는 abutment manipulation 등의 과정이 추가적인 골 소실을 야기한 것으로 생각된다. Interval I+II에서 W 군과 S 군 사이의 골 소실 양 차이는 미세 간극의 수평적 위치 변화의 양과 유사한 결과를 나타내었는데 이로 미루어 미세 간극의 수평적 이동은 임플란트 주위의 골 소실 양에 영향을 미칠 수 있다고 생각된다.

Soft tissue responses to differential shapes of the implant abutment (임플란트 지대주 모양에 따른 주위 연조직 반응에 관한 연구)

  • Ahn, Soo-Yong;Han, Chong-Hyun;Heo, Seong-Joo;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Lee, Hae-Jun;Chung, Chong-Pyoung;Han, Soo-Boo;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.1
    • /
    • pp.167-177
    • /
    • 2006
  • 연구배경 임플란트에 관한 전통적인 연구들은 주로 임플란트 매식체와 골조직간의 결합에 중점을 두어왔다. 최근 임플란트의 심미적 관점에 대한 관심이 높아지면서 임플란트 주위 연조직의 재건 및 유지에 대한 연구들이 많이 이루어지고 있다. 이번 연구는 임플란트 주위 연조직이 임플란트 지대주의 모양에 따라 어떻게 반응하는지 알아보고자 한다. 연구방법 및 재료 2 마리의 성견을 대상으로, 먼저 하악의 모든 소구치를 발치하고, 3개월의 치유 기간 후에 각 4분악에 실험에 사용된 3개의 다른 모양의 지대주를 가진 임플란트를 식립하였다: (1) 위로 벌어진 모양의 지대주 (2) 안쪽으로 오목하게 좁아진 지대주 (3) 평행한 모양의 지대주. 식립 순서는 무작위로 하였으며, 3개월 후 실험동물을 희생하고 조직 표본을 얻었다. 조직 표본은 광학 현미경을 통해 관찰하고, 상피, 결합조직, 전체 연조직의 수직적 거리를 측정하여 비교하였다. 연구 결과 이번 연구에서 임플란트 주위의 연조직을 측정한 결과, 접합 상피는 1.21 ${\pm}$ 0.47 mm, 결합조직은 1.16 ${\pm}$ 0.39 mm, 전체 연조직 두께는 2.37 ${\pm}$ 0.47 mm로 이전의 연구들과 비슷한 결과를 보였다. 지대주 주위의 연조직 중 결합조직이 많은 부위에서는 여러 주행 방향의 교원 섬유들이 관찰되었다. 그 중에서 결합조직이 차단막으로써의 역할을 할 수 있도록 하는 원형으로 주행하는 교원 섬유들이 모든 지대주 모양에서 관찰되었다. 특히 오목하게 좁아진 모양을 가진 지대주에서는 오목하게 파인 부분으로 많은 원형으로 주행하는 교원 섬유들이 관찰되었다. 오목한 모양의 지대주는 다른 모양의 지대주에 비해서 측면 방향의 연조직 두께가 두꺼웠다. 특히 위로 벌어진 모양의 지대주에 비해서 두꺼운 연조직을 확보할 수 있었으며, 내부에 많은 결합조직 교원 섬유들을 관찰할 수 있었다. 결론 이번 연구에서 오목한 모양의 지대주가 연조직을 두껍게 유지하고, 많은 원형으로 주행하는 교원 섬유들을 확보할 수 있었다. 이를 통해 오목한 여태의 지대주가 연조직 유지에 더 유리하고, 따라서 심미적인 부위에서 연조직의 퇴축을 예방하는데 더 유리하다고 할 수 있다.

Effect of rhPMP-2 coated implants on alveolar ridge augmentation in dogs (성견에서 골형성단백질이 코팅된 임플란트가 치조골 증대에 미치는 영향)

  • Park, Chan-Kyung;Kim, Jong-Eun;Shin, Ju-Hee;Ryu, Jae-Jun;Huh, Jung-Bo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.202-208
    • /
    • 2010
  • Purpose: This study was aimed to evaluate the effect of rhPMP-2 coated implants on alveolar ridge augmentation in dogs. Materials and methods: Six Beagle dogs were used in this study. Six 8.0 mm long anodized surface titanium implants were placed 5 mm into the mandibular alveolar ridge following 6 month of healing period after extraction. Each animal received three implants coated with rhBMP-2 and three uncoated control implants using the randomized split-mouth design. Radiographic examinations were undertaken immediately at implant placement (baseline), at weeks 4 and 8 after implant placement. The amount of bone augmentation was evaluated by measuring the distance from the uppermost point of the coverscrew to the marginal bone. Implant Stability Quotient (ISQ) values were measured immediately at implant placement and 8 weeks after implant placement. For the statistical analysis, Man-Whitney ranksum test and Wilcoxon signed rank test of SPSS 12.0 software were used (P=.05). Results: The BMP group exhibited radiographic vertical bone augmentation about $0.6{\pm}0.7$ mm at 8 weeks later while controls showed bone loss about $0.4{\pm}0.6$ mm. There was significant difference among the rhBMP-2 group and controls in bone level change (P<.05). The ISQ values were significantly higher in the BMP-2 group than the control group at 8 weeks later (P<.05), while there was no significant difference at surgery. Conclusion: Within the limitation of this study, the rhBMP-2 coated on anodized implant could stimulate vertical alveolar bone augmentation, which may increase implant stability significantly on completely healed alveolar ridge.