• Title/Summary/Keyword: 수직 단면

Search Result 446, Processing Time 0.038 seconds

Vertically Half Disc-Loaded Ultrawideband Monopole Antenna (VHDMA) with Horizontally Top-Loaded Small Disc (수평 원형 디스크가 로딩된 반원 디스크 초광대역 모노폴 안테나)

  • 이재욱;조춘식;김종면
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.11
    • /
    • pp.1051-1061
    • /
    • 2004
  • In this Paper, a new antenna(VHMDA) characteristics of half-circular/elliptical disc-loaded planar antennas with horizontally top-loaded small disc is studied by simulation and measurements with additional resonant structure. The transfer function characteristics of Gaussian pulse from the designed UWB transmitter antenna has been investigated. The radiation pattern of the proposed antenna in azimuth is nearly omni-directional response, which is usulally required in conventional monopole antenna. In addition to that, the simulation and measured results show that the return loss characteristics of VHDMA covers considerably large bandwidth with small area. From the measured results of the circular and half-circular disc-loaded monopole antennas with small disc mounted on the top, it is found that the half disc-loaded monopole antenna with additional structure can be comparable to the circular disc-loaded monopole antenna in respect o( size and electrical performances. Surface wave and dielectric losses often caused by the printed antenna using high dielectric constant does not occur in metallic planar antenna with good impedance matching and without lossy matching unit. This structure implies that the performance of return loss is directly related with the radiation efficiency.

Flow Separation Control Effects of Blowing Jet on an Airfoil (블로잉 제트에 의한 에어포일에서의 유동박리 제어효과)

  • Lee, Ki-Young;Chung, Heong-Seok;Cho, Dong-Hyun;Sohn, Myong-Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.12
    • /
    • pp.1059-1066
    • /
    • 2007
  • An experimental study has been conducted to investigate the flow separation control effects of a blowing jet on an elliptic airfoil at a Reynolds number of 7.84×105 based on the chord length. A blowing jet was obtained by pressing a plenum inside the airfoil and ejecting flow out of a thin jet slot that located in leading edge or trailing edge. The experimental results have shown that the blowing jet had an effect of suppressing the flow separation, resulting in the higher suction pressure distribution and higher normal force. The increase in Cn was more pronounced at higher incidence, whereas the effectiveness of the blowing jet reduced at lower incidences. The leading edge pulsating blowing with 90° was the most effective in controlling the flow separation than other types of blowing jet configuration tested in this research. Moreover, when the pulsating blowing was applied, the stall angle was postponed about 2°-3°. The continuous and pulsating blowing jet is a direct and effective flow separation control for improving the aerodynamic characteristics and performances of airfoil.

Development of an Inverse Method Using Orthogonal Basis Functions for the Evaluation of Boundary Tractions on an Elastic Body (탄성체 경계 트랙션을 구하는 문제에서 상호 수직 기저 함수를 사용한 역문제 해석 방법의 개발)

  • Kim, Sa-Young;Kim, Hyun-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.4
    • /
    • pp.487-493
    • /
    • 2010
  • Most structural analyses are concerned with the deformations and stresses in a body subjected to external loads. However, in many fields, inverse problems have to be interpreted to determine surface tractions or internal stresses from displacements measured on a remote surface. In this study, the inverse processes are studied by using the finite element method for the evaluation of internal stresses. Small errors in the measured displacements often result in a substantial loss of stability of an inverse system. In order to improve the stability of the inverse system, the displacements on a section near the region of the unknown tractions are predicted by using orthogonal basis functions. We use the Gram-Schmidt orthogonal technique to determine two bases for the displacements on a section near the region of the unknown tractions. Advantages over previous methods are discussed by using numerical examples.

Development of Wide Connection Method for Vertical Joints of Precast Concrete Walls (프리캐스트 콘크리트 벽체 수직접합부의 광폭형 연결방식 개발)

  • Choi, Eun-Gyu;Shin, Yeong-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.5
    • /
    • pp.549-556
    • /
    • 2009
  • This research analyzed the structural efficiency and application by improving the 100 mm width vertical joint to 150 mm and developing three connection methods to reduce the difficulty in assembling and handling PC walls. Moreover, nonlinear finite analysis was used for analyzing. From the analysis results, when double width connection was applied, the PC wall showed larger load capacity and ductility due to the steel bar sharing loads efficiently. Moreover, as the dimension of loops and the number of bars increased, the maximum load capacity increased as well. Also, among the double width connections, the largest capacity showed in the order of welding, ring and C type loop. However, in case of welding type loop connection, the ring type loop is more stable due to changes in different site conditions. Therefore, thorough quality control of welding is necessary.

Analysis for Realization of Vertical Wall in Holes by Applying Alternate High Pressure in the Punchless Piercing Process (무 펀치 피어싱 공정에서 교번식 고압 적용을 통한 구멍 내 직벽 구현 해석)

  • Lee, Sang-Wook;Um, Tai-Joon;Joo, Young-Cheol;Kim, Kug-Weon;Kwon, Kye-Si
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.5
    • /
    • pp.929-934
    • /
    • 2009
  • In this work, the punchless piercing process with application of alternate high pressure has been proposed as a method to obtain pierced holes having nearly vertical wall over thin metal plates. The numerical simulation considering Lemaitre damage model has been accomplished for the proposed method. The simulated results have been compared with those by conventional one-way punch less piercing process. It has been revealed that the fractured section made by pressure alternation method shows nearly steep wall where the deviation angle from the vertical line is as small as $3.6^{\circ}$.

A Pole-pole Electrical Survey for Groundwater (2극법 전기비저항 탐사에 의한 지하수탐사)

  • Cho Dong-heng;Jee Sang-keun
    • Geophysics and Geophysical Exploration
    • /
    • v.3 no.3
    • /
    • pp.88-93
    • /
    • 2000
  • The present study may be summarized as follows. By means of a pole-pole electrical survey, major geological features, i.e, fresh rocks, fractured & weak & saturated rocks, fresh water bearing aquifer, were successfully delineated in the surveyed area of a granite region in Korea. The subsequent Schlumberger sounding and drilling confirmed the existence of the acquifer at 60 m depth as expected. But one more minor acquifer which does not show up in the resistivity depth section was met at 100 m depth. A simple forward modelling leads the authors to believe that any other electrode configuration, e.g., Wenner, Schlumberger, dipole-dipole, pole-dipole, would not detect the deeper aquifer. Under these circumstances, further studies remain to be done in connection with the spatial resolution in the vertical direction.

  • PDF

Morphological difference of symphysis according to various skeletal types using cone-beam computed tomography (안면골격 유형에 따른 하악 전치 치조골의 형태 차이: Cone-beam CT를 이용한 정량적 평가)

  • Kwon, Hyun-Jin;Chun, Youn-Sic;Kim, Min-Ji
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.3
    • /
    • pp.215-222
    • /
    • 2014
  • Purpose: The aim of this study was to investigate differences between the morphology of the mandibular symphysis and four facial skeletal types. Materials and Methods: 40 cone-beam computed tomographies were selected and classified in to 4 groups according to their vertical and anterior-posterior skeletal patterns. The bone volume ($mm^3$) of the symphysis, the cross sectional area corresponding to the 4 mandibular incisors' axis: the cross sectional area of total bone ($mm^2$), the area of the cancellous bone ($mm^2$) and the thickness (mm) of labial and lingual alveolar bone at 2 mm, 3 mm under the cemento-enamel junction (CEJ) were measured. General linear model (GLM), Kruskal-Wallis test and Tukey honestly significant difference (HSD) test were subsequently used for statistical analysis. Results: The lingual cortical bone thickness of the lateral incisors at 2, 3 mm under CEJ was greater in the Class I low angle group than the other 3 groups (P < 0.05). There were no statistically significant differences in the volume of the mandibular incisor bony support, cross-sectional area of total bone and cancellous bone at the mandibular incisor' axis. Conclusion: Patients in Class I, low angle group have a thicker lingual mandibular symphysis than Class I, high angle patients.

Investigation of Water Leakage in Seosan A-Region Sea Wall using Integrated Analysis of Remote Sensing, Electrical Resistivity Survey, Electromagnetic Survey, and Borehole Survey (원격탐사, 전기탐사, 전자기탐사 및 시추공영상의 융합적 분석을 통한 서산지역 방조제 누수구역 판별)

  • Hong, Seong-In;Lee, Dongik;Baek, Gwanghyun;Yoo, Youngcheol;Lim, Kookmook;Yu, Jaehyung
    • Economic and Environmental Geology
    • /
    • v.46 no.2
    • /
    • pp.105-121
    • /
    • 2013
  • This study introduces integrated approach on detection of a leakage in a sea wall based on remote sensing, electric resistivity survey, electromagnetic survey, and borehole survey for the Seosan A-Region sea wall. The satellite temperature distribution from Landsat ETM+ data identifies water leakage distribution and period by analyzing temperature mixing patterns between sea water and fresh water. Electric resistivity survey provides both horizontal and vertical anomaly distributions over the sea wall showing below average electric resistivity. Electromagnetic survey(electrical conductivity survey) reveals the potential possible leakage areas with minimal background impact by comparing electrical conductivity values between high and low tides. Borehole image processing system confirmed the locations of anomalies identified from the other survey methods and distributions of vertical fracture zones. The integrated approach identified 41.7% of the sea wall being the most probable area vulnerable to water leakage and effectively approximated both horizontal and vertical distribution of water leakage. The integrated analysis of remote sensing, electric resistivity survey, electromagnetic survey and borehole survey is considered to be an optimal method in identifying water leakage distribution, period, and extent of fractures knowledged from the boreholes.

Feasibility Evaluation of CHS Diagrid Systems for Low/Mid-Rise Building Structure (원형강관 다이아그리드 시스템의 중저층 건축구조물 적용 타당성 평가)

  • Gam, Sam-Do;Kim, Tae-Jin;Kwak, Jin-I
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.84-87
    • /
    • 2009
  • 본 논문에서는 최근 초고층 건축물에 많이 활용되어지는 기둥-가새 시스템인 다이아그리드 시스템을 활용하여 중저층 건축물에 적용가능성을 평가하였다. 본 시스템은 튜브구조의 형태로 횡력에 대한 저항력이 우수하며 중력하중과 황하중을 기초와 지반에 안전하게 하중을 전달한다. 다이아그리드는 경사기둥과 보를 반복적으로 삼각형 형태로 배치되어 중력하중을 받을 경우 수직부재는 압축력을 보는 인장력을 받게 된다. 경사기둥과 보를 연결하는 접합부는 H-형강으로 설계 시 제작이 복잡하고 외관이 좋지 않다. 하지만 원형강관을 사용 할 경우 복합하지 않은 형태로 설계가 가능하고 외관이 우수하기 때문에 외부에 노출이 가능해진다. 또한 원형강관은 개방형 단면 부재에 비해 압축좌굴과 비틀림에 대한 성능 등이 우수하여 구조적인 성능이 우수하다. 원형강관을 이용하여 다이아그리드 시스템이 고층 건축물 뿐만 아니라 중저층 건축물에도 적용 타당성을 검토하였으며 원형강관 접합부 설계는 한계상태설계법이 사용 된 KBC2008(안)을 이용하여 설계하였다.

  • PDF

플라즈마 공정 모니터링용 사중극자 질량 분석기의 필라멘트 파손분석

  • Ha, Seong-Yong;Kim, Dong-Hun;Ju, Jeong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.93.2-93.2
    • /
    • 2015
  • 플라즈마를 포함한 반응성 가스 공정 분석용 사중극자 질량분석기의 필라멘트의 파손양상을 조사하였다. 또한 유전체 증착층이 이온원 성능에 미치는 영향을 분석하기 위하여 이온원의 일반적인 가동 전압 조건에서 Poisson방정식을 이용하여 전위를 수치 해석으로 구하였다. 사용중 파손된 필라멘트의 파단면을 주사전자현미경으로 관찰결과, 수직으로 절단되는 양상과 직경이 점차 작아지면서 erosion되는 두가지 양상을 보였다. 또한 파단면은 표면균열과 패시팅(faceting) 현상을 보였다. 필라멘트 사용시 가장 큰 문제는 패시팅(faceting)이다. 대부분의 결정에서는 다른 결정면보다 에너지 준위가 낮은 결정면이 존재한다. W 원자는 고온에서 확산 또는 증발하여 표면에서 다시 응축할 때 표면 에너지를 최소화하기 위한 독특한 평형 형상이 만들어 지는데 이것이 패시팅의 구동력이다. 이때 국부적으로 단면적이 감소하는 곳이 생기는데, 이 지점이 집중적으로 가열되고 증발이 가속화하여 파손된다. 파단면을 EDS 분석결과, 산화물을 포함한 F, Fe 및 C이 검출되었다. 이 F과 C는 공정중 사용된 CF4의 분해에 의한 것으로 생각되며, 파손된 필라멘트를 Ar 유도결합 플라즈마로 처리한 결과 이 F, Fe 및 C의 양이 감소하였다.

  • PDF