• Title/Summary/Keyword: 수직펌프

Search Result 111, Processing Time 0.025 seconds

Annual Performance Evaluation of Direct Expansion Vertical Closed-Loop Ground Source Heat Pump for Residential Application (주거용 직접순환식 수직밀폐형 지열원 열펌프의 연간 운전성능 평가)

  • Kim, Min-Sung;Baik, Young-Jin;Ra, Ho-Sang
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.114-122
    • /
    • 2012
  • Vertical closed-loop ground source heat pump systems(GSHP) have been installed widely in Korea since it can extract moderate temperature level of geothermal heat in a small area. As a ground heat exchanger, a vertical closed -loop type with brine circulation is mostly preferred since it is simple and less harmful to ground environment. However, it requires a secondary heat exchange loop between the refrigerant in a heat pump and the brine. By adding a geothermal heat exchanger in the secondary heat exchange loop, circulation pumps should be attached and the temperature difference between refrigerant and ground is increased, which are important parts of performance degradation. In this paper, annual and seasonal performances of direct expansion(DX) geothermal heat pump were estimated mathematically as an alternative of classical indirect geothermal heat pump based on the annual performance evaluation. As results, DX geothermal heat pump showed 43% higher annual performance than the classical U-tube geothermal heat pump.

Investigation of Exhaust Facility of Liquid Rocket Propulsion System (액체로켓 추진기관의 후류처리장치 고찰)

  • Cho, Nam-Kyung;Lee, Kwang-Jin;Han, Young-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.133-138
    • /
    • 2012
  • Exhaust facility has basically the role of flame deflector, and considering additional functions, it can be classified by noise/emission suppressor and altitude simulation facility. In this paper, principles of flame deflector, jet pump, emission suppression are presented for exhaust treatment facility. Principles of noise suppression caused by Mach wave mitigation, jet energy mitigation by water evaporation and condensation are shown. In addition, a concept of vertical exhaust treatment facility is presented applying basic principles aforementioned.

  • PDF

Cooling and Heating Energy Performance and Cost Analysis of Vertical Closed-loop Geothermal Heat Pump Coupled with Heat Storage Tank Compared to Conventional HVAC System (일반공조 시스템 대비 축열조와 연동된 수직밀폐형 지열히트펌프의 냉난방 에너지 성능 및 경제성 분석)

  • Kim, Min-Ji;Do, Sung-Lok;Choi, Jong-Min;Lee, Kwang Ho
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.11
    • /
    • pp.81-87
    • /
    • 2018
  • Among various types of geothermal heat pump systems, Vertical Closed-Loop Geothermal Heat Pump (VGSHP) has received increasing attention due to a variety of advantages such as the potential to be installed in a relatively small space and improved energy efficiency. In this research, the performance of VGSHP system coupled with heat storage tank was evaluated, by analyzing operational behavior of heat storage tank, the variations of heat pump energy performance due to the connection with heat storage tank, part load ratios characteristics of heat pump and the corresponding energy cost, compared to chiller and boiler based conventional system. The results of this study showed that the VGSHP system coupled with heat storage tank showed an energy saving effect of about 18% for cooling and about 73% for heating, and annual heating/cooling energy cost reduction of 43,000,000 KRW ($ 39,000), compared to the conventional air conditioning system. In addition, after considering both energy cost and initial investment cost including equipment, installation and auxiliary device expenses, payback period of approximately 11.8 years was required.

A Study on the Development of Increasing Gear Box for the High Speed Veritical In-Line Centrifugal Pump (수직축 인-라인 고속 원심펌프용 종속기 개발에 관한 연구)

  • Kim, Byung-Ok;Lee, Dong-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.393-398
    • /
    • 2002
  • In this study, the increasing gear boxes for the high speed vertical in-line centrifugal pump are developed through rotor dynamic analysis. The developed increasing gear boxes are two kinds for 18000rpm and 25000rpm at the output shaft. The gear sets suitable for high speed and high load are manufactured by investigating AGMA bending strength and AGMA surface strength severely. The rotor dynamic analysis on gear sets and bearings is performed in order to avoid the critical speeds and other troubles. As a result of study, the two increasing gear boxes for the high speed vertical in-line centrifugal pump are designed and manufactured.

  • PDF

Computer Simulation on the Performance of Air-Cooled Condenser for an Absorption Heat Pump (흡수식 열펌프용 공냉식 응축기의 성능특성에 관한 시뮬레이션)

  • 박윤철;민만기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.8
    • /
    • pp.1999-2011
    • /
    • 1995
  • Computer simulation was conducted to study performance characteristics of air-cooled condenser of a double effect absorption heat pump with variations of saturation pressures and mass flow rates of the refrigerant ; volume flow rates, relative humidities and temperatures of the air The vertically installed condenser had the staggered tube array with continuous plate fins of wavy type. When the saturation pressure of the condenser was decreased from 760 torr to 20 torr, heat transfer rates and condensing rates of refrigerant were decreased. If excess refrigerant flows in the condenser, the pressure and saturation temperature of the condenser were increased which makes the refrigerating capacity of an absorption heat pump reduced.

An Axial-type Self-bearing Motor for Small Vertical Axial-flow Pump (소형 수직형 축류 펌프를 위한 축방향 자기 부상 모터)

  • ;Yohji Okada
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.6
    • /
    • pp.223-232
    • /
    • 2001
  • Aiming at a small axial pump with a levitated rotor, an axial-type self-bearing motor is presented, which has a rotor wish four permanent magnets and two stators with two-pole three-phase windings. In this system, only the axial motion of rotor is actively controlled by two opposite self-bearing motors just like in the case of an axial magnetic bearing, while the other motions are passively stable. For rotation, It follows the theory of a four-pole three-phase synchronous motor. This paper Introduces schemes for design and control of the self-bearing motor and shows some experimental results to Prove the feasibility of application for the axial Pump.

  • PDF

하수처리 프로세서 제어를 위한 감시제어 시스템

  • 김현기;오성권;황희수;우광방
    • 전기의세계
    • /
    • v.39 no.6
    • /
    • pp.67-75
    • /
    • 1990
  • 하수처리 프로세스의 과제로는 우수침수, 수질보존, 자원의 유효이용이 그 주요내용이다. 이에 대응하기 위해 기상, 우량, 하천정보 시스템의 구성, 지식공학응용 우수펌프 운전제어, 하수의 고도처리기술 등의 방법이 행해지고 있다. 하수도는 생활환경의 개선, 침수의 방지, 공공 용수 지역의 수질보존의 측면뿐만 아니라 최근에는 하수도를 자원으로써 이용하는 관점으로부터 시서르이 공간이용, 처리수 및 슬러지의 다목적 활용도 중요한 과제로 되고 있다. 하수도 plant의 전기, 계장 기술을 구성하는 요소 기술은 전기(E), 계장(I), computer(C) 관계하는 기술을 종계로써 하고, 시스템설계로부터 시공까지의 engineering기술을 횡계로 한 통합 시스템 기술이다. 하수도 분야에 있어서의 감시제어 시스템은 종래의 계층화된 수직분산 방식에 덧붙여 계층마다 기능을 나누어 수평분산방식이 진행되고 있고, 최근에는 수직분산, 수평분산의 감시제어 시스템으로 이행하고 있다.

  • PDF

A Study on Vibration of Vertical Pump (수직펌프의 진동 연구)

  • Kim, Yeon-Whan;Kim, Hee-Soo;Lee, Jun-Shin;Bae, Yong-Chae;Lee, Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.58-63
    • /
    • 1997
  • The natural frequencies of the support system for a vertical pump, which are a key factor affecting the dynamic stability of the pump support system, are not easily predictable with analytical approaches only, due to the difficulties estimating the effective stiffness of the connections between the concrete base, the motor structure, the discharge elbow and the suction column of the pump system. This paper presents the results of a finite element analysis and an experimental study performed to identify and modify the characteristics of the pumping structure. The difficulties of modelling the effective stiffness were overcome by utilizing experimental results in the analysis. Based on analytical and experimental results, appropriate structural modifications are taken to reduce excessive vibration of the pump system to a satisfactory level.

  • PDF

Free Vibration of Vertica Pomp (대형수직펌프의 자유진동해석)

  • 배춘희
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.267-272
    • /
    • 2004
  • Vertical pump are widely used owing to the fact that they occupy small floor space. In this type of pumps, however, the vibrational problems are very important, since, in many cases, they have less stiffness in comparison with later pumps. This study presents a simple solution method for calculating the natural frequencies and modes of vertical pumps. In this study, a model of a vertical pump was developed and the nondimensional parameters for the vibrational characteristics of it were determined. Added mass was calculated for the effects of water and the transfer matrix method was used.

  • PDF