• Title/Summary/Keyword: 수직튜브

Search Result 108, Processing Time 0.032 seconds

Effects of Baffle Structure Variation on Heat Transfer Performance in a Shell-Tube Heat Exchanger (배플 구조변경이 Shell-Tube 열교환기의 열전달성능에 미치는 영향)

  • Hou, Rong-Rong;Cho, Joeng-Kwon;Yoon, Jun-Kyu;Lim, Jong-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3014-3021
    • /
    • 2015
  • Shell-tube heat exchanger is widely applied in industrial field by easily manufacturing as to various size and flow patterns. In this study, by changing baffle's cut direction, tilt angle and rotational angle as well as by using SST (Shear Stress Transport) $k-{\omega}$ turbulence model in ANSYS FLUENT v.14, the heat transfer rate and pressure drop characteristics of inner shell will be analyzed to improve heat transfer ability. As a result of analysis, heat transfer performance according to cut direction of baffle has been improved with vertical model B and angle $45^{\circ}$ model C than horizontal model A. In addition, the tilt $10^{\circ}$ of the baffle and rotational angle $0^{\circ}-90^{\circ}-180^{\circ}-270^{\circ}$ of model D showed better result in heat transfer rate and pressure drop.

Numerical Study on Heat Transfer and Flow Characteristics of Pin Fin with Swept Airfoil Shape Vortex Generator (후퇴익형 형상의 와류발생기가 있는 핀휜 유동의 전열 및 유동 특성 분석에 관한 수치적 연구)

  • Lee, Changhyeong;Oh, Yeongtaek;Bae, Jihwan;Lee, Deukho;Kim, Kuisoon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.4
    • /
    • pp.28-34
    • /
    • 2019
  • In this study, pin-fin arrays, which are widely used for cooling turbine blades, were studied. The vortex generator in pin-fin arrays is located in front of the circular tube. The cross-section of the vortex generator is NACA-9410. The purpose of this study is to analyze heat transfer performance and flow characteristics of pin-fin arrays. The position of vortex generator is changed with the vertical flow direction on the bottom wall. Pin-fin arrays were calculated with 6000, 10000 and 15000 Reynolds number. The commercial program ANSYS v18.0 CFX and the turbulence model $k-{\omega}$ SST were used. As a result, the heat transfer performance increased up to 5.8% and pressure loss increased less than 1%.

Deformation Characteristics of Zircaloy-4 Fuel Cladding due to Oxidation in Environment of High Temperature and Steam (고온, 수증기 속에서 산화된 질칼로이-4 핵연료 피복관의 변형 특성에 관한 연구)

  • Jung, Sung-Hoon;Suh, Kyung-Soo;Kim, In-Sup
    • Nuclear Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.218-227
    • /
    • 1986
  • Studies were conducted to determine the extent of oxidation and same of the mechanical property changes of Zircaloy-4 fuel cladding after it was exposed to hot steam environment. The purpose of these tests was to provide some informations on the embrittlement behavior of CANDU type fuel cladding, which could be experienced under the loss-of-coolant accident conditions. The Zircaloy fuel cladding tubes were exposed in a steam environment at the temperature of 90$0^{\circ}C$, 1,00$0^{\circ}C$. The growth of the ZrO$_2$ layer combined with an oxygen rich $\alpha$-phase layer into the Zircaloy tube material was found as a function of time t and temperature of steam exposure, E=1.1√Dt+0.002 where D is a temperature dependent diffusion coefficient. The tensile strength of the specimens exposed for a short period increased but decreased continuously with further exposure. The circumferential elongation was drastically changed with the exposure time while the hoop strength did't decrease greatly. The X-ray measurement of preferred orientation of the Zircaloy tube material indicated that grains in the as received tube were oriented such that the poles of the basal (0001) planes were predominantly radial, while the poles of the basal plane in the tube materials heattreated at 1,00$0^{\circ}C$ were oriented tangentially. It appears that this reoriented texture may contribute to lessening the decrease of the hoop strength of the heat treated Zircaloy tube material.

  • PDF

Crystal Growth of rutiles doped with Impurity Ions by Floating Zone Method (부유대용융법에 의한 불순이온 주입된 $TiO_2$단결정 성장 연구)

  • 이성영;유영문;김병호
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 1999.04a
    • /
    • pp.1-1
    • /
    • 1999
  • 부유대용융법에 의하여 불순이온의 종류와 각 이온의 주입 농도를 달리하는 Rutile 단결정을 성장하였다. 성장된 결정으로부터 제조한 박편시료를 이용하여 결정결함과 광투과도에 미치는 각 불순이온의 영향을 조사하였다. 결정성장용 주원료로 99.99%의 TiO2를 사용하고, 불순이온 주입을 위한 원료로서 99.99%의 Al2O3, H3BO3, Ga2O3, Sc2O3, V2O5, Fe2O3, ZrO2, Er2O3, Cr2O3를 각각 사용하였다. 불순이온의 종류에 따르는 영향을 조사하기 위하여 TiO2 99.8 atomic%-불순이온 0.2atomic%의 조성이 되도록 각 이온별로 원료를 정밀하게 평량하고 균일 혼합하였다. 불순 이온의 첨가량에 따르는 영향을 조사하기 위하여 Al2O3는 각각 pure, 0.2, 0.4, 0.6 atomic%를, Cr2O3는 pure, 0.003, 0.05, 0.2 atomic%를 각각 치환하여 원료를 조합하였다. 균일 혼합된 원료를 직경 8mm의 고무 튜브에 넣고 CIP(Cold Isostatic Press0에서 2000kg/$\textrm{cm}^2$의 압력으로 성형한 후 150$0^{\circ}C$에서 1시간 소결함으로서 결정성장용 다결정 원료를 합성하였다. 합성된 다결정을 double ellipsoidal mirror 내에 설치하고,halogen lamp로 가열하여 원료의 한쪽 끝을 용융한 다음, 20rpm의 회전속도, 3-5mm/hr의 성장속도로 하는 유속 1$\ell$/min의 O2 분위기속에서 부유대용융법에 의하여 결정을 성장하였다. 성장된 결정을 성장축에 수직한 방향으로 각각 절단, 연삭, 연마한 박편을 이용하여 편광하에서 low-angle grain boundaries 및 기타의 결정결함을 관찰하였으며, 0.3$\mu\textrm{m}$~0.8$\mu\textrm{m}$ 범위 및 0.6$\mu\textrm{m}$~3.4$\mu\textrm{m}$ 범위에서의 투과 및 흡수 스펙트럼을 측정하였다. 결정 성장 결과 B3+, Er3+, Cr3+ 이온은 Ti4+ 이온과 이온의 크기 차이가 심하여 결정의 정상적인 성장을 방해하는 물성을 나타냈고, V5+, Cr3+ 이온은 흑색의 결정, Fe3+ 이온은 적갈색의 결정으로 성장되었다. Al3+, Zr4+, Al3+의 순서로 투과도가 높아지는 것이 관찰되었다. 불순이온의 농도에 따른 영향으로서 Al3+ 이온의 경우 주입농도가 높아질수록 low angle boundary와 oxygen deficiency가 감소하였고, 투과율은 조금 감소하거나 큰 차이가 없는 것으로 나타났다. 반면에 Cr3+ 이온을 주입한 경우 0.003 atomic%에서 최적의 물성을 보였으며, 주입농도가 높아질수록 결정성장이 어려워지고 광의 투과도가 급격히 저하되었다.

  • PDF

Experimental Study of Transition to Secondary Acoustic Instability at Downward-Propagating Premixed Flame in a Tube (튜브 내 하향 전파하는 예혼합 화염의 이차 열음향 불안정성 천이에 관한 실험적 연구)

  • Park, Juwon;Kim, Daehae;Park, Dae Geun;Yoon, Sung Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.7
    • /
    • pp.915-921
    • /
    • 2020
  • Thermoacoustic instability caused by air conditioning in a combustion chamber has emerged as a problem that must be solved to establish a stable combustion system. Thermoacoustic instability is largely divided into primary and secondary acoustic instability. In this study, an experimental study of the effects of heat losses was conducted to investigate the mechanism of secondary acoustic instability. To generate the secondary acoustic instability, a quarter-wavelength resonator with one open end and one closed end was used, and the inside of the resonator was filled with premixed gases. Subsequently, secondary acoustic instability with downward-propagating flames could be realized via thermal expansion on the burnt side. To control heat losses qualitatively, an additional co-axial tube was installed in the resonator with air or nitrogen supply. Therefore, additional diffusion flames can be formed at the top of the resonator depending on the injection of the oxidizer into the co-axial tube when rich premixed flames are used. Consequently, secondary acoustic instability could not be achieved by increasing heat losses to the ambient when the additional diffusion flame was not formed, and the opposite result was obtained with the additional diffusion flame.

Strength and Deformation Capacities of Short Concrete Columns with Circular Section Confined by GFRP (GFRP로 구속된 원형단면 콘크리트 단주의 강도 및 변형 능력)

  • Cho, Soon-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.1
    • /
    • pp.121-130
    • /
    • 2007
  • To investigate the enhancement in strength and deformation capacities of concrete confined by FRP composites, tests under axial loads were carried out on three groups of thirty six short columns in circular section with diverse GFRP confining reinforcement. The major test variables considered include fiber content or orientation, wrap or tube type by varying the end loading condition, and continuous or discontinuous confinement depending on the presence of vortical spices between its two halves. The circumferential FRP strains at failure for different types of confinements were also investigated with emphasis. Various analytical models capable of predicting the ultimate strength and strain of the confined concrete were examined by comparing to observed results. Tests results showed that FRP wraps or tubes provide the substantial increase in strength and deformation, while partial wraps comprising the vertical discontinuities fail in an explosive manner with less increase in strength, particularly in deformation. A bilinear stress-strain response was observed throughout all tests with some variations of strain hardening. The failure hoop strains measured on the FRP surface were less than those obtained from the tensile coupons in all tests with a high degree of variation. In overall, existing predictive equations overestimated ultimate strengths and strains observed in present tests, with a much larger scatter related to the latter. For more accuracy, two simple design- oriented equations correlated with present tests are proposed. The strength equation was derived using the Mohr-Coulomb failure criterion, whereas the strain equation was based on entirely fitting of test data including the unconfined concrete strength as one of governing factors.

COMPARATIVE STUDY ON THE SHEAR BOND STRENGTH OF ALL-IN-ONE DENTIN BONDING SYSTEM APPLIED TO PRIMARY TEETH (유치에 적용된 All-in-One 상아질 접착 시스템의 전단강도에 관한 비교연구)

  • Kim, Dong-Cheol;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.4
    • /
    • pp.560-568
    • /
    • 2007
  • This study was performed to compare the shear bond strength of primary enamel & dentin treated by AQ Bond $Plus^{TM}$ and G $Bond^{TM}$, recently developed 6th generation dentin bonding system, to that of Single $Bond^{TM}$ being widely used. Also by observing the resin tag under scanning electron microscope, Resin tags of each material were also observed under scanning electron microscope and compared to one another. The possibility of clinical application of All-in-One system which has an advantage to reduce chair-time for children with difficult behavior pattern was evaluated. The results obtained are as follows: 1. No statistically significant difference between groups was found in shear bond strength of primary enamel. 2. In primary dentin, the shear bond strength of AQ Bond $Plus^{TM}$ was $1.15\;{\pm}\;0.37\;MPa$, G $Bond^{TM}$ was $1.69\;{\pm}\;0.74\;MPa$ and Single $Bond^{TM}$ was $0.56\;{\pm}\;0.11\;MPa$. There were no statistical difference between AQ Bond $Plus^{TM}$ and G $Bond^{TM}$ and between G $Bond^{TM}$ and Single $Bond^{TM}$, whereas statistically significant difference was found between AQ Bond $Plus^{TM}$ and Single $Bond^{TM}$. 3. Under scanning electron microscope, resin tags observed in AQ Bond $Plus^{TM}$ and G $Bond^{TM}$ were very weak and tangled while strong and thick tags were shown with many lateral branches in Single $Bond^{TM}$. The result of the present study coupled with the advantages of less working time over the previous generation suggests that All-in-One system might be effectively used in adhesive dental procedures for primary teeth.

  • PDF

STUDY ON THE SHEAR BOND STRENGTH OF ALL-IN-ONE DENTIN BONDING SYSTEM (우치에 대한 All-in-one 상아질 결합제의 전단결합강도 비교 연구)

  • Park, Hyung-Joo;Yoo, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.4
    • /
    • pp.661-672
    • /
    • 2006
  • This study was performed to compare the shear bond strength of AQ Bond $Plus^{TM}$ with AQ $Bond^{TM}$ and Single $Bond^{TM}$. Also by observing the fractured interface under scanning electro-microscope, the fracture pattern and the quality of hybrid layer were analyzed. The possibility of clinical application of all-in-one system which has an advantage to reduce chair time for children with difficult behavior pattern was evaluated, The results obtained are as follows ; 1. There was no significant difference between AQ $Bond^{TM}$ and AQ Bond $Plus^{TM}$ in shear bond strength and Single Bond showed the highest bond strength with statistical significant difference (p<0.05). 2. Adhesive fracture pattern was mainly observed in both enamel/dentin in AQ $Bond^{TM}$ and AQ Bond $Plus^{TM}$ group while Single Bond group showed equal numbers for cohesive and adhesive pattern. 3. Under scanning electro-microscope, resin tags observed in AQ $Bond^{TM}$ and AQ Bond $Plus^{TM}$ were very weak and tangled while strong and thick tags were shown with many lateral branches in Single Bond. Careful case selection and accurate clinical application is recommended when using AQ $Bond^{TM}$ and AQ Bond $Plus^{TM}$considering the result showing its weaker strength than Single $Bond^{TM}$.

  • PDF