• Title/Summary/Keyword: 수직관류

Search Result 16, Processing Time 0.03 seconds

A temperature adjustment process of stratified fluid induced simultaneously by sidewall thermal variation and vertical through-flow (용기의 온도변화와 수직관류가 동시에 작용하는 성층유체의 과도유동)

  • Park, Jun-Sang;Hyun, Jae-Min
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.450-455
    • /
    • 2001
  • An analytical study is made of transient adjustment process of an initially stationary, stably-stratified fluid in a square. The boundary walls are highly-conducting. The overall Rayleigh number $R_a$ is large. Considerations are given to both opposing (${\delta}w/{\delta}T>0$) and cooperating (${\delta}w/{\delta}T<0$) configurations. The flow character in opposing configuration can be classified into (a) a forced-convection dominaut mode (${\delta}w/{\delta}T>1/\sqrt{2}$), (b) a buoyancy-convection dominant mode ($0<{\delta}w/{\delta}T<1/\sqrt{2}$), and (c) a static mode (${\delta}w/{\delta}T{\cong}1/\sqrt{2}$). Global evolutionary processes are depicted. and physical rationalizations are provided.

  • PDF

동시획득 $T_{1}T_{2}^{*}$ 강조 경사 자장 펄스열을 사용한 관류량과 투과도 측정

  • 김은주;김대홍;이희조;허용민;이상훈;이삼현;서진석
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.103-103
    • /
    • 2002
  • 목적:자화율 대조법을 사용한 관류 영상에서 동시획득 $T_{1}T_{2}^{*}$ 강조 경사 자장 펄스열을 사용하여 Gd-DTPA에 의한 $T_{1}T_{2}^{*}$ 감소 효과를 동시에 획득하여 종양의 치료 효과, 판정에 중요한 기준을 제시할 수 있는 정확한 관류 정보를 얻고자 한다. 대상 및 방법: Gd-DTPA에 의한 $T_{1}T_{2}^{*}$ 감소 효과를 동시에 획득하기 위하여 기존의 이중 경사자장 펄스열을 수정, 동시획득 $T_{1}T_{2}^{*}$ 강조 경사자장 펄스열을 개발하였고, 시간 해상도를 높이기 위하여 key-hole 방법을 사용하였다. 고정 phantom으로 Sephadex를 다양한 농도의 Gd-DTPA 용액에 swelling하여 사용하였고, 관류 phantom으로는 Sephadex와 Dialyzer를 사용하였다. Sephadex는 swelling 하였을 때 $T_1$, $T_2$값이 생체 조직의 값과 비슷하고, 물을 관류시킬 수 있어 생체 모형에 적합한 phantom이다 .관류 phantom은 정량 펌프에 연결하여 사용하였다. Sephadex 관류 phantom에서는 분당 약 4$m\ell$ 속도로 관류시키면서 25 mM Gd-DTPA을 0.1$m\ell$ 일시 주입하여 관류 방향에 수직인 coronal 영상을 약 15분 동안 얻었다. 투과도를 구하기 위한 phantom으로는 hollow fiber type Dialyzer를 사용하였고, in vivo에서 1차 관류 이후에 현관 밖에서의 Gd농도가 높고 혈관 내부의 농도가 낮은 상태를 만들기 위하여 fiber 바깥쪽으로 500 mM Gd-DTPA 2 ml를 미리 넣어두고 fiber 내부로 이보다 낮은 농도의 Gd 용액을 관류시키면서 약 1시간동안 영상을 얻었다. 관류 영상에서 $T_1$/$T_{2}^{*}$ 감소 효과를 구분하여 구한 $\DeltaR_1$, $\DeltaR_2$ 곡선의 적분값으로부터 관류량을 구하고, 2 구획 모델을 적용하여 투과도를 구했다.

  • PDF

동시획득 $T_{1}{/}T_{2}^{*}$강조 경사 자장 펄스열을 사용한 관류량과 투과도 측정

  • 김은주;김대홍;이희조;허용민;이상훈;이삼현;서진석
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.127-127
    • /
    • 2002
  • 목적: 자화율 대조법을 사용한 관류 영상에서 동시획득 $T_{1}{/}T_{2}^{*}$ 강조 경사 자장 펄스열을 사용하여 Gd-DTPA에 의한 $T_{1}{/}T_{2}^{*}$ 감소 효과를 동시에 획득하여 종양의 치료 효과, 판정에 중요한 기준을 제시할 수 있는 정확한 관류 정보를 얻고자 한다. 대상 및 방법: Gd-DTPA에 의한 $T_{1}{/}T_{2}^{*}$ 감소 효과를 동시에 획득하기 위하여 기존의 이중 경사자장 펄스열을 수정, 동시획득 $T_{1}{/}T_{2}^{*}$ 강조 경사자장 펄스열을 개발하였고, 시간 해상도를 높이기 위하여 key-hole 방법을 사용하였다. 고정 phantom으로 Sephadex를 다양한 농도의 Gd-DTPA 용액에 swelling하여 사용하였고, 관류 phantom으로는 Sephadex와 Dialyzer를 사용하였다. Sephadex는 swelling 하였을 때 $T_1$, $T_2$값이 생체 조직의 값과 비슷하고, 물을 관류시킬 수 있어 생체 모형에 적합한 phantom이다. 관류 phantom은 정량 펌프에 연결하여 사용하였다. Sephadex 관류 phantom에서는 분당 약 4$m\ell$ 속도로 관류시키면서 25 mM Gd-DTPA을 0.1$m\ell$ 일시 주입하여 관류 방향에 수직인 coronal 영상을 약 15분 동안 얻었다. 투과도를 구하기 위한 phantom으로는 hollow fiber type Dialyzer를 사용하였고, in vivo에서 1차 관류 이후에 혈관 밖에서의 Gd 농도가 높고 혈관 내부의 농도가 낮은 상태를 만들기 위하여 fiber 바깥쪽으로 500mM Gd-DTPA 2$m\ell$를 미리 넣어두고 fiber 내부로 이보다 낮은 농도의 Gd 용액을 관류시키면서 약 1시간동안 영상을 얻었다. 관류 영상에서 $T_{1}{/}T_{2}^{*}$ 감소 효과를 구분하여 구한 $\Delta{R}_{1}$, $\Delta{R}_{2}^{*}$ 곡선의 적분값으로부터 관류량을 구하고, 2 구획 모델을 적용하여 투과도를 구했다.

  • PDF

염해도조사연구

  • 김영식
    • 전기의세계
    • /
    • v.22 no.6
    • /
    • pp.65-70
    • /
    • 1973
  • 최근 대단위 용량의 발변전소 건설과 아울러 확대되는 초고압 송배전 시설은 공히 그 계통의 신뢰성향상이 필연적으로 요구되고 있다. 발변전소의 전기기기나 송배전 시설물의 애자나 애관류가 염진이나 연진에 의해 받는 피해는 적지않다. 따라서 우리나라 해안에 인접하고 있는 주요발변전소 및 송배전 시설물을 대상으로 염진오손도를 조사하여 지역별로 오손기준을 설정하여 신증설되는 발변전소 및 송배전 시설물의 내염설계 및 유지보수의 참고자료를 얻기 위하여 염진해가 기할곳으로 예상되는 울산, 고리, 금산, 삼척, 강릉, 인천, 순천, 여수, 제주 등지를 조사대상지역으로 선정하여 염해도조사를 실시하였다. 시료는 250mm 현수애자 일련 12개씩을 29개소에서 무과전 수직조가하여 매일 정기일정에 시료를 채취하여 등가염분량을 구하여 인천지구 시료애자는 오손상태에서 건조섬락시험 및 윤활상태에서 섬락시험들을 하였다.

  • PDF

모듈식 증기발생기를 사용한 일체형 원자로의 예비 개념설계

  • 김종인;김긍구;김용완;이두정;장문희
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.275-282
    • /
    • 1996
  • 일체형 원자로는 증기발생기 및 가압기를 압력용기 내에 설치한 것으로서 연결배관이 없기 때문에 배관의 파단에 의한 대형 냉각재 상실사고를 근원적으로 배제하고 전체계통을 단순화 시킬 수 있다. 증기발생기는 대부분 관류식으로서 일체식과 모듈식이 사용되고 있다. 본 연구에서는 모듈식 나선형 증기발생기를 사용한 일체형 신형경수로의 예비 개념설계를 수행하였다. 가압기는 원자로 내에 별도의 용기를 설치하는 내장형 자기가압기를 채택하였다. 제어봉 구동장치는 핵분열 반응열을 이용한 원자로 기동을 위하여 반응도를 미세하게 조정하는 것이 가능하고 지진하중과 같은 동하중의 영향을 최소화하기 위하여 원자로용기 외부로의 돌출부분을 최소화하는 설계개념을 채택하였다. 냉각재 펌프는 Canned Motor Pump를 원자로용기 상부에 수직으로 직접 부착하는 개념을 사용하였다.

  • PDF

The Comparison of Image Quality Using Body Contour and Circular Method with L-mode in Myocardial Perfusion SPECT (Tl-201을 이용한 심근관류 SPECT에서 Body contour와 Circular mode의 영상 획득 차이에 따른 영상의 질 비교)

  • Kim, Sung-Hwan;Nam, Ki-Pyo;Ryu, Jae-Kwang;Yoon, Soon-Sang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.3-7
    • /
    • 2012
  • Purpose : In myocardial perfusion SPECT, the type of orbit (circular vs. body contouring) that affect the image quality is still on the debate. Presently in the nuclear medicine field, the body contouring orbit acquisition is widely used to improve the image quality on the myocardial perfusion SPECT. But in case of body contouring acquisition using the vertical method with dual detect machine, there is a tendency of increasing the radius. In this research, we compared body contouring orbit acquisition with circular orbit acquisition, so we suggest ideal method that reduces the radius for improving image quality. Materials and Methods : Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on equally with counts from patient's body. The study was performed under six different conditions. To compare image quality according to the radius, we increased radius sequentially per step during circular orbit acquisition. On the other hand, sensors that protect a collision and reduce the radius automatically were used to acquire image during body contouring orbit acquisition. So we compared FWHM value of apex. In clinical studies, we analyzed the 40 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center in August 2011. To acknowledge the differences according to the radius, we acquired the results two times using circular orbit acquisition and body contouring orbit acquisition. Results : In phantom study, we analyzed that increase of radius resulted in changes of FWHM value. It was 5.41, 6.24, 6.33, 6.42, 6.93 mm. On the other hand, using the body contouring orbit acquisition, FWHM value was 6.23 mm. In clinical study, difference of average radius between two methods was 2.5 cm (circular orbit acquisition was more close to patients). Conclusion : Through the experiments using Anthropomorphic torso phantom and patients data, we found that FWHM value of circular orbit acquisition was lower than body contouring orbit acquisition. As a result, if the difference of average radius exists approximately 3 cm, circular orbit type acquisition is better than body contouring type acquisition. But clinical investigation is only aimed to average radius, so it needs more investigation in comparison of patient's image.

  • PDF

MR Images of Spontaneously Involuted Atretic Cephalocele Concomitant with Persistent Falcine Sinus in an Adult (성인에서 지속적인 낫형동을 동반한 자연퇴축된 위축뇌탈출증의 MR영상소견)

  • Cho, Joon;Roh, Hong-Gee;Moon, Won-Jin;Kim, Mi-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.117-120
    • /
    • 2006
  • Atretic cephalocelces are defined as skin-covered midline subscalp lesions that contain meninges and rest of glial and/or central nervous system tissue. When the straight sinus is absent or rudimentary, the falcine sinus can be recanalized to enable venous drainage. Although the atretic cephalocele or persistent falcine sinus has largely been described in the pediatric population, it is a rarely observed in the adult population. We report a unique case of spontaneously involuted atretic cephalocele coexistent with persistent falcine sinus in an adult. MR images and MR venography were useful for diagnosis and accurate anatomical depiction.

  • PDF

Development of Thermal Performance Tester for Non-Homogeneous Insulation Pannels Installed Vertically (수직으로 설치된 비균질 평판 단열재용 성능시험장치 개발)

  • Oh, Hong Young;Song, Ki O;Jeon, Hyun Ik;Cho, Sun Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.4
    • /
    • pp.153-157
    • /
    • 2016
  • In case of metal insulation, which is produced by stacking stainless steel sheets and air layers in a multi-stack manner at a specific thickness, insulation performance will be evaluated based on thermal transmittance rather than the intrinsic physical properties of each material such as thermal conductivity. However, there is no standard for measuring thermal transmittance targeted for non-homogeneous insulation which is used in relatively high temperature conditions such as a power station. In this study, the thermal conductivity of homogeneous insulation acquired by the standardized guard hot plate method and the thermal conductivity of homogeneous insulation measured by the newly developed performance tester were compared to verify the confidence level of the tester. As a result, thermal conductivity acquired by the newly developed thermal transmittance tester was about 6% higher than the thermal conductivity measured by the existing guard hot plate method under the anticipated service temperature conditions.

Analysis on the Oceanic Circulation and Pollutant Transport near a Wolsung Nuclear Power Plant (월성원전주변의 해수유동 및 오염물 이동해석)

  • Park, Geon-Hyeong;Kim, Ki-Chul;Lee, Jung-Lyul;Suh, Kyung-Suk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.250-250
    • /
    • 2011
  • 지정학적으로 3면이 바다로 접하고 있는 우리나라 해안가 주변의 원자력발전소는 관류형 냉각 방식(Once-through cooling System)을 채택하고 있기에, 이 계통을 통과한 냉각수는 주변해역으로 흘러들어가 주변 환경에 영향을 줄 수 있다. 또한 동해 주변 인접국들의 활발한 원자력 이용과 방사능 물질의 수송 등으로 인해 방사능 사고 위험이 증대됨에 따라 동해 원전 주변의 해양방사성물질 거동에 대한 필요성이 제기되고 있다. 이에 따라 동해의 해양환경을 조사 분석하여 해역에서의 오염 물질의 거동 파악이 중요하고, 산업시설 주변 연안의 오염물 이동 및 해석을 위해 오염물의 시 공간적으로 농도를 추정하는 것이 중요한 사항이다. 따라서 본 연구에서 수직 수평적으로 2차원 및 3차원화가 용이한 EFDC 모델을 사용하였다. 국립해양조사원에서 발간하는 DC103의 수치해도를 이용하여 모델영역은 동서방향으로 171km, 남북방향으로 235km로 설정하고, 격자간격은 $1km{\times}1km$의 정방향 격자를 사용하여 동해 월성 주변의 조위 시계열 검증 및 조화분석을 통한 검증을 실시한 결과 관측한 결과와 양호한 재현성을 나타내었다. 또한 국립수산과학원에서 제공되고 있는 년별 수온, 염분 자료 등의 해양환경과 지형적 특성을 고려하여 오염 물질의 이동 경로를 파악함으로써 사고시 피해를 줄이고자 한다.

  • PDF

Prediction of Water Quality Variation Caused by Dredging Urban River-bed (도시하천의 하상퇴적토 준설에 따른 수질변화 예측)

  • Jo, Hong-Je;Lee, Byeong-Ho;Kim, Jeong-Sik;Lee, Geun-Bae
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.2
    • /
    • pp.137-148
    • /
    • 2002
  • The purpose of this study was to examine the effect of water quality improvement due to dredging the bottom deposit at the downstream of a urban river. The finite difference method was used to analyze the water quality variations caused by the depths of dredging and intercepting ratios of the goal years. 21 boring points were selected along the 11.2km river reach running through a metropolitan city. The pollution levels of the deposits from the bored Points were examined by the leaching test. The improvement effect of the water quality, measured as changes of COD, were carried at under drought, minimal, and normal flow. The result indicates that the dredging of the contaminated sludge contributes the improvement of the water quality.