• Title/Summary/Keyword: 수지상

Search Result 709, Processing Time 0.026 seconds

A Case Study on the Heat budget of the Marine Atmosphere Boundary Layer due to inflow of cloud on observation at Ulleungdo (울릉도에서 구름 유입시 관측한 해양대기경계층의 열수지에 관한 사례연구)

  • Kim, Hee-Jong;Yoon, Ill-Hee;Kwon, Byung-Hyuk
    • Journal of the Korean earth science society
    • /
    • v.25 no.7
    • /
    • pp.629-636
    • /
    • 2004
  • In order to study developments of the marine atmosphere boundary layer in cloud incoming, important parameters like heat advection, surface layer heat flux, and radiation energy were estimated using the rawinsonde, AWS data, satellite images, and buoy data which was installed at the East Sea. We explained the variation and the development of mixed layer in terms of surface layer heat flux and long wave radiation under the cloudy sky. The heat flux was obtained by means of the bulk method. Conservation of heat was analysed by heat budget equation, which was consist of buoy data in the East sea, and sounding data at Ulleungdo and at Pohang. During the inflow of cloud, radiative cooling at the surface after was suppressed and long wave radiation from cloud played a role of warming. The surface layer temperature was also remained warm by influence of warm advection from south-easterly direction. The air temperature in night was increased, as a result, mixed layer was not destroyed and The nocturnal boundary layer was composed of the mixed layer and the residual layer.

Characterization of Porous Asphalt Concrete Coated with MMA Resin (아크릴 수지로 코팅한 배수성 아스팔트 콘크리트의 특성 평가)

  • Choi, Tae-Jun;Lee, Hyun-Jong;Kim, Tae-Woo;Song, Jae-Hyok
    • International Journal of Highway Engineering
    • /
    • v.11 no.2
    • /
    • pp.111-120
    • /
    • 2009
  • This paper presents a fundamental findings of the functional and structural performance of the porous asphalt concrete coated with MMA resin. To evaluate the structural performance, cantabro, wheel tracking, moisture sensitivity and indirect tensile fatigue tests are performed. The tests results show that the cantabro loss is reduced three times and fatigue resistance is significantly increased after the specimens are coated with MMA resin. However there are little changes in the rutting and moisture damage resistances before and after the coating. Air voids, permeability and BPT(British Pendulum Test) tests are conducted to study the functional performance. It is observed form the tests that the air voids and permeability are slightly decreased after the coating. However, the changes in the air voids and permeability are negligible. The skid resistance of the coated specimens is lower than reference specimens. However, the skid resistance is maintained beyond the level of the reference specimens when silica sands are chipped on top of the coated surface.

  • PDF

Effect of BLU Ingredient on Electrical and Optical Properties of Light Diffusing Film used for TFT-LCD TV (백라이트 유니트 구성요소가 TFT-LCD TV용 광확산필름의 전기, 광학적 특성에 미치는 영향)

  • Ahn, Cheol-Heung;Kim, Geon-Joong
    • Applied Chemistry for Engineering
    • /
    • v.17 no.4
    • /
    • pp.397-402
    • /
    • 2006
  • We have investigated the effect of each ingredient in the light diffusing film (LDF) which was used as backlight unit (BLU) of TFT-LCD TV on physical, electrical, thermal and optical properties of LDF. In anti-blocking layer, the excellent anti-blocking ability was obtained when 0.5~1.5 wt% of acrylic bead was added, and good decay-time and water-stability were shown when 0.8 wt% of tertiary ammonium salt was added. Optimal results for adhesion strength, curing rates and flexibility on the surface of PET film have been obtained in the light diffusing layer by using acrylic polyol as a binder resin, and by addition of 30~35 wt% non-yellowing type HDI crosslinker. In addition, the highest normal luminance value was obtained by addition of 250 wt% poly-dispersive polystyrene ($20{\mu}m$ PS) and polymethylmethacrylate ($20{\mu}m$ PMMA) beads into the binder resin (100 wt%). The higher normal luminance could be got for PMMA beads than PS beads because of the transmittance difference.

Synthesis of High Loading PONF-g-GMA Anion Exchange Fiber Containing Ion Exchange Resin and Their Adsorption Properties of Vanadium (이온교환 수지를 함유한 PONF-g-GMA High Loading 음이온교환 섬유의 합성 및 바나듐 흡착 특성)

  • Baek, Ki-Wan;Park, Seung-Wook;Nho, Young-Chang;Hwang, Taek-Sung
    • Polymer(Korea)
    • /
    • v.31 no.4
    • /
    • pp.315-321
    • /
    • 2007
  • Aminated PONF-9-GMA ion exchange fabrics were synthesized by radiation induced graft copolymerization. Hybrid ion exchange fabrics combined with aminated PONF-g-GMA fabrics and anionic ion exchange resin were also fabricated by hot melt adhesion method and then their adsorption properties were investigated. Ion exchange capacity of the hybrid ion exchange fabrics was higher than ion exchange fabric and was lower than bead resin. The maximum value was 4.18 meq/g. Adsorption breakthrough time for vanadium of the hybrid ion exchange fabric was 550 min, which was faster than bead resin but slower than fibrous ion exchanger. The Breakthrough time of the hybrid ion exchange fabrics gets longer with increasing pH. The initial breakthrough time occurred around 400 min with increasing vanadium concentration.

Optimization for Electro Deposition Process of PC/ABS Resin Surface Treatment (수지의 하전 입자빔 전처리 공정의 최적화)

  • Park, Young Sik;Shim, Ha-Mong;Na, Myung Hwan;Song, Ho-Chun;Yoon, Sanghoo;Jang, Keun Sam
    • The Korean Journal of Applied Statistics
    • /
    • v.27 no.4
    • /
    • pp.543-552
    • /
    • 2014
  • High bandwidth RF such as Bluetooth, GPRS, EDGE, 3GSM, HSDPA is papular in the mobile phone market. A non-conducting metal coating process requires an e-beam deposition of metal, two steps of UV hard coating primer and top coating; however, it is inefficient. We navigate to the electron beam irradiation conditions(resin surface treatment conditions) in the PC/ABS resin injection process. By analyzing the experimental results, we find the optimum development conditions for the electro deposition pre-treatment process and mass production lines using the plasma generated electron beam source.

Burnup Measurement of Irradiated Uranium Dioxide Fuel by Chemical Methods (화학적 방법에 의한 핵연료의 연소도 측정)

  • Kim, Jung-Suk;Han, Sun-Ho;Suh, Moo-Yul;Joe, Kih-Soo;Eom, Tae-Yoon
    • Nuclear Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.277-286
    • /
    • 1989
  • Destructive methods are used for the turnup determination of an irradiated PWR fuel. One of the methods includes U, Pu, Nd-148 and Nd-(145+146) determination by an isotope dilution mass spectrometry using triple spikes (U-233, Pu-242 and Nd-150). The method involves two sequential ion exchange resin separation procedures. Pu is eluted from the first anion exchange resin column (Dowex AG 1$\times$8) with 12 M HCl-0.1 M HI mixed solution, followed by U elution with 0.1 M HCl. Nd is isolated from other fission products on the second anion exchange resin column (Dowex AG 1$\times$4) with a nitric acid-methanol eluent. Each fraction is analysed by thermal ionization mass spectrometry. The difference between Nd-148 and Nd-(145+146) method is found with an average 2.07%. The results are compared with those by the heavy element method using U and Pu isotopes and by the destructive y-spectrometric measurement of Cs-137. The dependences of isotope composition of U and Pu on burn-up, and correlation between those isotopes are illustrated graphically.

  • PDF

Ion Migration Failure Mechanism for Organic PCB under Biased HAST (고온고습 전압인가(Biased HAST) 시험에서 인쇄회로기판의 이온 마이그레이션 불량 메커니즘)

  • Huh, Seok-Hwan;Shin, An-Seob;Ham, Suk-Jin
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.1
    • /
    • pp.43-49
    • /
    • 2015
  • By the trends of electronic package to be smaller, thinner and more integrative, organic printed circuit board is required to be finer Cu trace pitch. This paper reports on a study of failure mechanism for PCB with fine Cu trace pitch using biased HAST. In weibull analysis of the biased HAST lifetime, it is found that the acceleration factor (AF) of between $135^{\circ}C/90%RH/3.3V$ and $130^{\circ}C/85%RH/3.3V$ is 2.079. A focused ion beam (FIB) was used to polish the cross sections to reveal details of the microstructure of the failure mode. It is found that $Cu_xO/Cu(OH)_2$ colloids and Cu dendrites were formed at anode (+) and at cathode (-), respectively. Thus, this gives the evidence that Cu dendrites formed at cathode by $Cu^{2+}$ ion migration lead to a short failure between a pair of Cu nets.

A Study on Temperature and Retaining Ion Effect on the Separation of Lanthanides (란탄계열원소들의 양이온교환분리에서의 온도와 보유이온의 영향에 관한 연구)

  • Young-Gu Ha;Bong-Il Ji
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.6
    • /
    • pp.601-606
    • /
    • 1989
  • The effects of temperature and retaining ion on the separation factor (${\alpha}$) and distribution ratio (D) of some lanthanides ($Pr^{3+},\;Nd^{3+},\;Sm^{3+},\;and\;Er^{3+}$) have been studied in the EDTA solution as an elutant by using Amberite IR 120 + resin. The retaining ions on the resin were ${NH_4}^+,\;Na^+,\;K^+,\;Mg^{2+},\;Ca^{2+},\;Zn^{2+}$and $Ce^{3+}$. Separation factor of Nd/Pr is much improved by using $Ce^{3+}$ as retaining ion. The distribution ratios were decreased with the increase of temperature, but separation factors did not always increase with the increase of temperature. However, in the case of $Ce^{3+}$ as retaining ion, separation factors of Nd/Pr and Sm/Nd were increased with the increasing of temperature. And also in the case of $Zn^{2+}$ as retaining ion, separation factor of Er/Sm was increased with the increasing of temperature.

  • PDF

백판지 Varnish Coating적성 개선에 대한 연구

  • 곽상효;황명동;이경현;박광만;이순용
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2001.04a
    • /
    • pp.79-79
    • /
    • 2001
  • 백판지는 포장용기로 사용되기 때문에 인쇄적성 이외에 다양한 후가공적성이 요구 된다. V Varnish Coating도 이러한 후가공적성 중의 하나로서 국내 인쇄소에서는 기계 코팅으로 불리 우며, 목적은 표면에 고분자수지 피막을 입힘으로써 인쇄물의 광택을 높여서 상품가치를 높이고 수운침투와 같은 외부환경의 변화로부터 상품을 안전하게 보관하기 위함이다. arnish C Coating은 인쇄기의 마지막 Unit에서 인쇄와 동일한 방식으로 진행되는데, 코팅액의 배합은 인쇄소와 인쇄물에 따라 상이하다. 본 연구는 Varnish Coating(OI하 기계코팅) 광택향상을 통 한 품질개선 목적으로 수행되었다. 기계 코팅의 특 성 을 파 악 하 기 위 해 서 Gas Chromatography / Mass Spectrometer와 FT -IR Sp e ectrometer를 사용하여 성문운석을 실시해본 결과 코팅액으로 사용되는 광택바니스는 아크 랄과 페놀수지를 툴루엔 계열의 용매에 녹인 용액이고, 흐$\mid$석제로 쓰이는 인쇄바니스는 스티 렌수지를 동일한 용매에 녹인 용액으로 조사되었다. 기계코팅광택 저하현상의 원인파악을 위해서 도공층의 공극구조를 Mercury Porosimeter를 이용하여 파악한 결과 기공의 부피가 상 대적으로 크게 나타났다. 위의 결과를 토대로 기계코팅광택 저하는 코팅액이 과도한 기공부피를 갖는 도공층 내부 로 대부분 홉수되고 표면에 적은 양만이 잔류하기 때문으로 판단하고 해결방안은 도공층의 기공부피를 줄이는 쪽으로 정하였다. Mayor Coater와 QC를 이용하여 Coating Color Formula t tion 번경실힘을 진행하여 도공지 물성을 분석하였다. 그 결과 Double Coating의 Top Color에 서 강력한 상호작용을 하는 Protein과 콜레이를 감량 하고 경질탄산칼숨을 배제하여 기공의 부피를 줄인 경우 기계코팅광택 향상효과가 두드러지게 나타났다. 이러한 Lab 실험을 바탕으로 결정된 Color Formulation에 대한 현장실험을 진행하였고 Lab 평가 및 실인쇄 평가 결과 원하는 수준의 기계코팅광택 향상을 얻을 수 있었다. 몇 차례의 현장실험과 Long-Run Test한 제품들에 대한 물성을 문석한 결과 기계코팅굉택은 인쇄 광택과 같은 경향을 나타냈으며 실협실적으로 간단하게 측정되는 물성 중에서 Air Permeability와 강한 음의 상관관계롤 보였다.

  • PDF

Treatment Efficiency of Non-Point Source Pollutants Using Modified Filtration System (개선된 여과형 시설의 비점오염물질 처리효율 평가)

  • Kang, Hee-Man;Choi, Ji-Yon;Kim, Lee-Hyung;Bae, Woo-Keun
    • Journal of Wetlands Research
    • /
    • v.13 no.2
    • /
    • pp.161-169
    • /
    • 2011
  • The objective of this study was to evaluate the efficiency of a modified filtration system treating non-point source (NPS) pollutants. The developed Best Management Practice (BMP) technology was designed based on the geographical and climatic characteristics of the site. A lab-scale test experiment was conducted using three different hydraulic loading rates representing the first flush flow, average flow and overflow conditions during a rainfall event. Water quality analysis was performed on the water samples taken at the inflow, outflow and infiltration during the test experiment of the lab-scale BMP. Also, the water and mass balance at different hydraulic loading rates was determined. Results from the lab-scale test experiment showed that the lab-scale BMP had a high removal efficiency of 80-90% for all NPS pollutants. The overflow test condition obtained the lowest removal efficiency among the hydraulic loading rates because it gave less opportunity for the pollutants to be filtered and retained inside system. The infiltration ratio was approximately 1 % of the inflow and outflow. Increasing the infiltration ratio requires technical approach of soil amendment where the BMP is installed.