• Title/Summary/Keyword: 수조 상부 방사선

Search Result 5, Processing Time 0.032 seconds

Study for Reduction Effect of Pool Top Radiation in Research Reactor by Using Ion Exchanger of Hot Water Layer (고온층계통의 이온교환기에 의한 연구로 수조 상부 방사선의 저감효과에 대한 연구)

  • Park, Yong-Chul;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.4 s.5
    • /
    • pp.40-47
    • /
    • 1999
  • A hot water layer (HWL hereinafter) was installed at the depth of 1.2 m from the pool surface to reduce the radiation level at the pool top. After the HWL system was improved by the replacement of the filter with the Ion Exchanger to capture the Na-24, to purify the pool water of HWL and finally to reduce the radiation at the pool top. It was confirmed by the performance test of the pump and the measurement of the pressure difference through the Ion Exchanger and the strainer, that the flow characteristics of HWL system was not adversely affected after the system modification. Also the flow analysis using the pressure loss coefficients of the Ion Exchanger and strainer, calculated by the Darcy formula, could predict the flow variations by pressure changes within $10\%$ error in comparison with the field test results. It was also confirmed that HWL was maintained with the depth of 1.2 m from the pool surface because each electric water heater was electrically and thermodynamically maintained at 30 kW and the temperature of HWL was maintained with $5^{\circ}C$ higher temperature than that of pool water. Finally, it was confirmed that the pool top radiation was saturated and stabilized below 10000 nG/hr within 24 hours as the ion exchanger captured the main nucleus, Na-24 and purified the pool water of HWL.

  • PDF

A Monitoring Ability of the High-Performance Color CCD Camera under High Dose-Rate Gamma Ray Irradiation Environments (고 선량율 감마선 조사 환경에서의 고성능 칼라 CCD 카메라의 관측성능)

  • Cho, JaiWan;Choi, Young Soo;Seo, Yong Chil;Jeong, KyungMin
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2014.04a
    • /
    • pp.811-814
    • /
    • 2014
  • 일본 후쿠시마 제일 원자력발전소의 대지진/쓰나미에 이은 원자로 건물 수소폭발 사고의 수습 과정에서 사용후 핵연료 저장조에 보관되어 있는 핵연료의 안전문제가 대두되었다. 사용후 핵연료의 잔열 성분을 냉각시키고, 그리고 사용후 핵연료가 방출하는 고선량 방사선을 차폐시키기 위해서 일정 깊이 이상의 수조에 사용후 핵연료를 저장한다. 사용후 핵연료 저장조에 냉각수 공급이 중단되면, 사용후 핵연료의 고유 잔열에 의해 수조의 물이 증발하여 수위가 감소하게 된다. 계속해서 냉각수 공급이 되지 않으면, 사용후 핵연료의 잔열은 증가하게 되고, 수조의 물은 비등하여 증발은 가속화 된다. 사용후 핵연료 저장조의 수위가 고갈되면 고선량의 감마선이 방출된다. 수조의 수위가 정상적일 경우 사용후 핵연료 저장조의 공기중 감마선 선량율은 0.15mSv/h 이다. 수조의 수위가 사용후 핵연료 상부 꼭대기를 기준으로 2m, 1m, 및 0m (핵연료 노출) 로 감소하게 되면, 사용후 핵연료 저장조의 공기중 감마선 선량율은 500mSv/h, 50Sv/h, 및 5kSv/h 로, 급격히 증가한다. 본 논문에서는 사용후 핵연료 저장조 감시카메라의 관측 성능을 평가하기 위해, 고성능 칼라 CCD 카메라에 대해서 1 kGy/h 의 고선량율로 감마선 조사실험을 수행하였다. 이에 대한 실험결과를 기술한다.

Reduction Characteristics of Pool Top Radiation Level in HANARO (하나로 수조 방사선 준위의 저감 특성)

  • Park, Yong-Chul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.5 no.1 s.14
    • /
    • pp.49-54
    • /
    • 2002
  • HANARO, 30 MW of research reactor, was installed at the depth of 13m in an open pool. The $90\%$ of primary coolant was designed to pass through the core and to remove the reaction heat of the cote. The rest, $10\%$, of the primary coolant was designed to bypass the core. And the reactor coolant through and bypass the core was inhaled at the top of chimney by the coolant pump to prevent the radiated gas from being lifted to the top of reactor pool. But, the part of core bypass coolant was not inhaled by the reactor coolant pump and reached at the top of reactor pool by natural convection, and increased the radiation lovel on the top of reactor pool. To reduce the radiation level by protecting the natural convection of the core bypass flow, the hot water layer (HWL, hereinafter) was installed with the depth of 1.2 m from the top of reactor pool. As the HWL was normally operated, the radiation level was reduced to five percent ($5\%$) in comparing with that before the installation of the HWL. When HANARO was operated at a higher temperature than the normal temperature of the HWL by operating the standby heater, it was found that the radiation level was more reduced than that before operation. To verify the reason, the heat loss of the HWL was calculated by Visual Basic Program. It was confirmed through the results that the larger the temperature difference between the HWL and reactor hall was, the more the evaporation loss increased. And it was verified that the radiation level above was reduced mote safely by increasing the capacity of heater.

Reduction Characteristics of Pool Top Radiation Level in HANARO (하나로 수조 방사선 준위의 저감 특성)

  • Park, Yong-Chul
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.221-226
    • /
    • 2001
  • HANARO, 30MW of research reactor, was installed at the depth of 13m of open pool, The $90\%$ of primary coolant was designed to pass through the core and to remove the reaction heat of the core. The rest $10\%$, of the primary coolant was designed to bypass the core. And the reactor coolant through and bypass the core was inhaled at the top of chimney by the coolant pump to protect that the radiated gas was lifted to the top of reactor pool. But, the part of core bypass coolant was not inhaled by the reactor coolant pump and reached at the top of reactor pool by natural convection and increased the radiation level on the top of reactor pool. To reduce the radiation level by protecting the natural convection of the core bypass flow, the hot water layer (HWL, hereinafter) was installed with the depth of 1.2m from the top of reactor pool. As the HWL was normally operated, the radiation level was reduced to five percent ($5\%$) in comparing with that before the installation of the HWL. When HANARO was operated with higher temperature than the normal temperature of the HWL by operating the standby heater, it was found that the radiation level was more reduced than that before operation. To verify the reason, the heat loss of the HWL was calculated. It was confirmed through the results that the larger the temperature difference between the HWL and reactor hall was, the more the evaporation loss was increased. And it was verified that the radiation level above was reduced more safely by increasing the capacity of heater.

  • PDF