• Title/Summary/Keyword: 수정빈법

Search Result 3, Processing Time 0.016 seconds

Developing The Prediction Program of Heat and Cooling Loads by Modified Bin Methods (수정빈법을 이용한 냉난방부하 예측 프로그램 개발)

  • Lee, M.K.;Kim, J.T.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.4
    • /
    • pp.21-28
    • /
    • 2001
  • It is a time since sustainable architecture become a main issue of design concept in 21C. However, it is necessary to develope the tool estimating energy loads and uses in our architectural conditions for energy saving design. This study aims to develope the E-Load program to predict heat and cooling loads of houses. The program is developed by modified bin methods derived from ASHRAE TC 4.7. It consists of 4 divisions such as files, data inputs, energy load estimations and output options. The main processes of energy load estimations are based on ASHRAE fundamentals. The developed E-Load program is a easy and valid tool to predict heat and cooling loads of buildings.

  • PDF

Analysis of energy consumption of office building by thermal resistance-capacitance method (열저항-열용량법에 의한 사무실용 건물의 소비에너지 해석)

  • Lee, C.S.;Choi, Y.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.1-13
    • /
    • 1997
  • This paper reports the dynamic analysis of energy consumption for an office building by heat resistance-capacitance method. If a building is divided into several wall components and the wall components is replaced by one thermal capacitance and several thermal resistances, the building becomes an electric circuit. By solving the simultaneous equations of the circuit, the dynamic heat transfer characteristics and the energy consumption rate of the building were predicted. Accuracy of modified BIN method was evaluated by the present resistance-capacitance method. The result shows that modified BIN method overpredicts the heating load of the office building 15%. Annual energy consumptions of equipments(fan, boiler, chiller) for various ventilating control system(CAV, VAV, FCU+VAV, FCU+CAV) were compared. FCU+CAV shows the minimum annual energy consumption.

  • PDF

Comparison on Heating & Cooling Loads Analysis in Buildings with Modified Bin Method (수정(修正)빈법(法)에 의한 건물(建物)의 기간(期間) 열부하(熱負荷) 해석(解析)에 관한 비교(比較) 연구(硏究))

  • Sohn, J.Y.;Yoon, D.W.;Yee, J.J.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.6
    • /
    • pp.675-685
    • /
    • 1988
  • The purpose of this paper is to present the fundamental information for setting up more accurate and easier heat loads analysis method by examing and comparing Modified Bin Method with Dynamic loads calculation and Extended Degree Day Method. For this comparison, monthly and annual loads calculation are performed in perimeter zones of model office building in Seoul by the above each Method. The results of Modified Bin Method are approximated to those of Dynamic loads calculation Method, and the correlations of the methods are specifically described in this paper.

  • PDF