• Title/Summary/Keyword: 수의 영상진단

Search Result 1,906, Processing Time 0.03 seconds

A Case of Micturition Syncope in a Child (소아에서 발현한 배뇨 후 실신 1례)

  • Lee, Sun Youn;Ryu, Su Jeong;Kim, Deok Soo;Kim, Young Hwue;Ko, Tae Sung;Kim, Jae Moon
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.12
    • /
    • pp.1274-1278
    • /
    • 2003
  • Syncope in children and adolescents have a common occurrence according for up to 15% before adulthood. Micturition syncope, a kind of situational syncope, can be considered a form of reflex syncope. It can typically occur in healthy young men after rising from bed in the early morning who experience sudden loss of consciousness during or immediately after urination. The mechanism of micturition syncope is not completely understood, but it has been suggested that vasovagal reflex mediated bradycardia and peripheral vasodilation and decreased venous return due to Valsalva effect and standing position lead to the decrease in cerebral blood flow resulting in syncope. The causes of syncope are variable. So complete history taking, physical examination, electrocardiography, exercise stress test, echocardiography, head-up tilt table test, electroencephalography(EEG), brain magnetic resonance image and urodynamic study should be required for the diagnosis of micturition syncope. There were several reports about micturition syncope. However, literature of micturition syncope at the pediatric age has rarely been reported in Korea so far. Therefore, we report a case of a 9-year-old boy with micturition syncope with typical EEG findings of high amplitude delta wave and flattening during syncope.

Fixed prosthesis restoration in edentulous patient fully implanted without considering definitive prosthesis: A case report (최종 보철물에 대한 고려 없이 전악 임플란트 식립된 환자의 고정성 보철 수복 증례)

  • Chun, Young-Hoon;Pae, Ahran;Kwon, Kung-Rock;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.427-435
    • /
    • 2017
  • The most important factor in the treatment of fully edentulous patients using implants is the shape of the definitive prosthesis. After the shape of the definitive prosthesis is determined, residual bone analysis and selection of the implant type, number and position should be followed. In this case, for restoration of an edentulous patient fully implanted (except the maxillary right lateral incisor) without considering definitive prosthesis, facial esthetics and possibility of fixed type prosthesis were evaluated using complete denture. It was determined that the fixed type prosthesis was possible. Implants that could not be used for the definitive prosthesis were excluded from the treatment plan and fixed type provisional restorations were fabricated. After four months of provisional restorations, the patient showed stable occlusion and esthetic satisfaction. Definitive prosthesis was made of zirconia using CAD/CAM (computer aided design and computer aided manufacturing). The results were satisfactory during the 3 months of follow-up period after termination of treatment.

Establishment of Quality Control System for Angiographic Unit (IVR장치의 성능 평가 기준 개발)

  • Kang, Byung-Sam;Son, Jin-Hyun;Kim, Seung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.1
    • /
    • pp.236-244
    • /
    • 2011
  • Recently, the number of interventional procedures has increased dramatically as an alternative of invasive surgical procedure. The need for the quality control program of the angiographic units has also increased, because of concerns about the increased patient dose and the importance of image quality of angiographic units for the successful procedures. The purpose of this study was to propose an optimal guideline for the quality control program of the angiographic units. We reviewed domestic and international standards about medical imaging system and we evaluated the quality of 61 angiographic units in Korea with the use of NEMA 21 phantom. According to the results of our study, we propose a guideline for the quality control program of the angiographic units. Quality control program includes tube voltage test, tube current test, HVL test, image-field geometry test, spatial resolution test, low-contrast iodine detectability test, wire resolution test, phantom entrance dose test. Proposed reference levels are as follows: PAE < $\pm$ 10% in tube voltage test, PAE < $\pm$ 15% in tube current test, minimum 2.3 mmAl at 80 kVp in HVL test, minimum 'acceptable' level at image-field geometry test, 0.8 lp/mm for detector size of 34-40cm, 1.0 lp/mm for detector size of 28-33cm, 1.2 lp/mm for detector size of 22-27cm in spatial resolution test, minimum 200mg/cc in low contrast iodine detectability test, phantom entrance dose should be under 10R/min, 0.012 inch wire should be seen at static wire resolution test, and 0.022 inch wire should be seen at moving wire resolution test.

Property of Focal Spot of Electron Beam Depending on the Anode Angle of X-ray Tube Using a Finite Element Method (유한요소법을 이용한 X-선관 양극각도에 의존하는 전자빔 초점 특성 연구)

  • Park, Tae-Young;Noh, Young-Il;Lee, Sang-Suk;Park, Rae-Jun;Kim, Ki-Seon
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.2
    • /
    • pp.52-57
    • /
    • 2015
  • The focal spot of electron beam depending on the anode angle in the structure and major parts of the X-ray tube was investigated by the OPERA-3D/SCALAR simulation program. The simulation worked on four spaces with with two spaces, including anode and cathode of X-ray tube, by applying the finite element method analysis. The analytical model and dimension for the emission orbit of thermal electrons made from one filament of the focused X-ray cathode is affected to the penumbra of detector for the X-ray depending on any real focal spot size. The model shape of focusing cap and focusing tube with an anode target angle and a cathode filament is analyzed by the current density distribution of thermal electrons. The focusing width of thermal electrons for the X-ray tube depended on the anode angle (${\theta}$). The focusing value of electron beams at a region of anode angle having $10^{\circ}{\sim}17^{\circ}$ maintained to below value of $70{\mu}m$. The minimum focal size of the electron beam was $40{\mu}m$ at an anode angle of $15^{\circ}$. The focused X-ray tube of many variables depended on the thermionic emission of hot electrons from the target trajectory. The focusing tube will contribute to the real design of X-ray for the development of future diagnosis medical device.

Natural History of Conservatively Treated Posterior Cruciate Ligament Injury (보존적으로 치료된 급성 단독 후방십자인대 손상의 자연 경과)

  • Ahn, Jin-Hwan;Seo, Hee-Soo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.1
    • /
    • pp.13-19
    • /
    • 2007
  • Purpose: We investigated the natural history of acute, isolated posterior cruciate ligament injuries treated conservatively. Materials and Methods: Between February 1999 and October 2006, we evaluated retrospectively the results of acute, isolated posterior cruciate ligament injuries treated conservatively. The subjects consisted of 21 patients. At initial and follow up visits physical examination, $KT-2000^{TM}$ arthrometer and MRI were performed to assess improvement on the knee stability and continuity of the posterior cruciate ligament. IKDC (International Knee Documentation Committee) knee scoring and quadriceps muscle strength were also checked in all population. Comparing the results of initial and follow up examinations we assessed the natural history of acute, isolated posterior cruciate ligament injuries treated conservatively. The mean follow up period was 22.7 months. Results: The posterior drawer test showed 14 cases of Grade I, 6 cases of Grade II and 1 case of Grade III progressing 18 cases of Grade I and 3 cases of Grade II. The mean difference of 5.7mm by $KT-2000^{TM}$ arthrometer was changed Into 2.7mm and the continuity of posterior cruciate ligament initially checked by 48.1% on MRI increased to 69.7%. The mean quadriceps muscle strength was grade 'Good' and mean IKDC knee score was nearly grade 'A'. Conclusion: Our study suggests that patients with acute, isolated posterior cruciate ligament injuries treated conservatively may get good clinical outcomes on clinical situation and MRI.

  • PDF

3-Dimensional Computed Tomography of Atlantoaxial Instability in Three Dogs (개에서 컴퓨터단층영상의 3차원 재구성을 통한 환축추골 아탈구 진단 3례)

  • Ahn, Se-Joon;Choi, Soo-Young;Lim, Soo-Ji;An, Ji-Young;Lee, In;Kwon, Young-Hang;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.26 no.5
    • /
    • pp.490-494
    • /
    • 2009
  • A 2-year-old Maltese and a 5-month-old Yorkshire terrier were presented with ataxia. Tetraparesis was observed in a 9-year -old Yorkshire terrier. The localizations of the lesions suggested brain or cervical spinal cord by the neurological examination, and the following images was achieved: radiography, axial images of computed tomography (CT), reconstruction image of CT such as multi-planar reformation(MPR) and 3-dimensional(3D) reconstruction and magnetic resonance imaging (MRI). On radiography, the misalignment between atlas (C1) and axis (C2), absent dens of axis, and increased space between the dorsal arch of C1 and spinous process of C2 were found. The discontinuation between dens and body of C2 was identified through axial CT images, and the fragmentation of dens separated from axis was observed through MPR and 3D image in all case. The hyperintense lesions and the spinal cord compression on T2-weighted MR images were represented in a dog with tetraparesis, the others represented only spinal cord compression. Three dogs were diagnosed as atlantoaxial instability (AAI) by dens fracture of C2. The dog with tetraparesis was euthanized due to guarded prognosis. The others were recovered completely. It is difficult to differentiate dens fracture of C2 from abnormal dens such as agenesis and hypoplasia. We thought that CT is very useful to evaluate the dens of C2 and differentiate the causes of AAI, and the reconstruction images of CT such as MPR and 3D make the translation of the fragmented dens or axis of AAI more precisely evaluate.

Evaluation of Gestational Diabetes Mellitus Risk Factors Using Abdominal Subcutaneous Fat Thickness for Early Pregnancy in the US Imaging (초음파영상에서의 임신초기 복부피하지방두께를 이용한 임신성당뇨 위험인자 평가)

  • Kim, Changsoo;Yang, Sung-Hee;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.35-40
    • /
    • 2017
  • The purpose of this study was to investigate the relationship between abdominal subcutaneous fat thickness(ASFT) and maternal gestational diabetes mellitus(GDM) measured by ultrasound at period of pregnancy. We compared maternal age, pre-pregnancy body mass index, and weight gain during pregnancy in 286 pregnant women who were diagnosed with early pregnancy ASFT and high GDM screening test(50 g OGTT) of more than 140 mg/dL. ROC curve analysis was used to determine the cut-off value of ASFT for GDM prediction. Maternal age and weight gain during pregnancy were not related to GDM in the mid-trimester and pre-pregnancy body mass index and earely pregnancy ASFT were significantly different between normal and GDM high risk groups. The cut-off value of ASFT for GDM prediction was 2.23 cm(AUC 0.913. Sensitivity 76.19%, Specificity 93.72%). ASFT measured by ultrasound in early pregnancy was useful as an important index for predicting mid-trimester GDM prediction. Therefore, ASFT can be used as an auxiliary diagnostic index for early recognition of GDM.

Improved Vapor Recognition in Electronic Nose (E-Nose) System by Using the Time-Profile of Sensor Array Response (센서 응답의 Time-Profile 을 이용한 전자 후각 (E-Nose) 시스템의 Vapor 인식 성능 향상)

  • Yoon Seok, Yang
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.329-334
    • /
    • 2004
  • The electronic nose (E-nose) recently finds its applications in medical diagnosis, specifically on detection of diabetes, pulmonary or gastrointestinal problem, or infections by examining odors in the breath or tissues with its odor characterizing ability. The odor recognition performance of E-nose can be improved by manipulating the sensor array responses of vapors in time-profile forms. The different chemical interactions between the sensor materials and the volatile organic compounds (VOC's) leave unique marks in the signal profiles giving more information than collection of the conventional piecemal features, i.e., maximum sensitivity, signal slopes, rising time. In this study, to use them in vapor recognition task conveniently, a novel time-profile method was proposed, which is adopted from digital image pattern matching. The degrees of matching between 8 different vapors were evaluated by using the proposed method. The test vapors are measured by the silicon-based gas sensor array with 16 CB-polymer composites installed in membrane structure. The results by the proposed method showed clear discrimination of vapor species than by the conventional method.

Artificial Neural Network System in Evaluating Cervical Lymph Node Metastasis of Squamous Cell Carcinoma (편평세포암종 임파절 전이에 대한 인공 신경망 시스템의 진단능 평가)

  • Park Sang-Wook;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won;You Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.149-159
    • /
    • 1999
  • Purpose: The purpose of this study was to evaluate cervical lymph node metastasis of oral squamous cell carcinoma patients by MRI film and neural network system. Materials and Methods: The oral squamous cell carcinoma patients(21 patients. 59 lymph nodes) who have visited SNU hospital and been taken by MRI. were included in this study. Neck dissection operations were done and all of the cervical lymph nodes were confirmed with biopsy. In MR images. each lymph node were evaluated by using 6 MR imaging criteria(size. roundness. heterogeneity. rim enhancement. central necrosis, grouping) respectively. Positive predictive value. negative predictive value. and accuracy of each MR imaging criteria were calculated. At neural network system. the layers of neural network system consisted of 10 input layer units. 10 hidden layer units and 1 output layer unit. 6 MR imaging criteria previously described and 4 MR imaging criteria (site I-node level II and submandibular area. site II-other node level. shape I-oval. shape II-bean) were included for input layer units. The training files were made of 39 lymph nodes(24 metastatic lymph nodes. 10 non-metastatic lymph nodes) and the testing files were made of other 20 lymph nodes(10 metastatic lymph nodes. 10 non-metastatic lymph nodes). The neural network system was trained with training files and the output level (metastatic index) of testing files were acquired. Diagnosis was decided according to 4 different standard metastatic index-68. 78. 88. 98 respectively and positive predictive values. negative predictive values and accuracy of each standard metastatic index were calculated. Results: In the diagnosis of using single MR imaging criteria. the rim enhancement criteria had highest positive predictive value (0.95) and the size criteria had highest negative predictive value (0.77). In the diagnosis of using single MR imaging criteria. the highest accurate criteria was heterogeneity (accuracy: 0.81) and the lowest one was central necrosis (accuracy: 0.59). In the diagnosis of using neural network systems. the highest accurate standard metastatic index was 78. and that time. the accuracy was 0.90. Neural network system was more accurate than any other single MR imaging criteria in evaluating cervical lymph node metastasis. Conclusion: Neural network system has been shown to be more useful than any other single MR imaging criteria. In future. Neural network system will be powerful aiding tool in evaluating cervical node metastasis.

  • PDF

Evaluation of Inflammatory Disease in the Nasal Cavity and Paranasal Sinuses using CT in Dogs and Cats (개와 고양이에서 컴퓨터단층촬영술을 이용한 비강의 염증성 질병 평가)

  • Choi, Ho-Jung;Lee, Ki-Ja;Park, Seong-Jun;Jeong, Seong-Mok;Song, Kun-Ho;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.27 no.1
    • /
    • pp.42-45
    • /
    • 2010
  • Inflammatory sinonasal disease was diagnosed in five dogs and two cats with clinical signs of nasal discharge and epistaxis. Survey radiography and CT were performed in all of patients. CT scan of the rostral cranium was performed with a thickness of 2 or 5 mm. Nasal cytology and culture from nasal smear were performed immediately after CT examination. Remarkable increase of opacity in the nasal cavities and frontal sinuses was observed in only 3 cases. On CT images, the cavitating lesions were isodense in nasal cavity (7 cases), frontal sinuses (3 cases), and nasopharynx (2 cases) with destruction of the nasal septum (4 cases), maxillary turbinates (5 cases), maxilla (3 cases), and hard palate (3 cases). The lesions were enhanced after intravenous contrast administration in 5 cases and were not enhanced in 2 cases. Inflammatory cells were observed in nasal cytology. Most of the cultures from nasal smear were bacteria. CT is useful to diagnose sinonasal disease and is more accurate in demonstrating the extent and character of lesions of nasal cavity than radiography.