• Title/Summary/Keyword: 수압관리

Search Result 96, Processing Time 0.03 seconds

A Study on the Mechanical Characteristics of Tunnel Structures and Ground Behavior by Synthetic Analysis Method with Tunnel Monitoring Results used (터널의 계측결과 종합분석에 의한 지반의 거동 및 터널 구조체의 역학적 특성 연구)

  • Woo, Jong-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.3
    • /
    • pp.115-124
    • /
    • 2003
  • In this study, the relationships between the displacement and stress of the tunnel using various analysis methods were compared with monitoring results carried out during construction and maintenance monitoring. The behavior of tunnel were measured in the subway tunnel passing comparative soft the weathering and analyzed both security and mechanical characteristics of the tunnel lining. With the results of simplified monitoring observed in top heading and bench excavation tunnel, it is confirmed that the crown settlement is larger than the surface settlement. it is interesting to note that the crown settlement and the crown shotcrete lining stress are widely used monitoring items for the back analysis. It is analyzed that the residual water pressure applied in the drainage type tunnel is reasonable.

Proposal of Youngjong-do 112 Block Demo-Plant for Application of Smart Water Grid (SWG 적용성을 위한 영종도 112블록 데모플랜트 구축 방안)

  • Han, Kuk Heon;Park, Hyun Ki;Kim, Young Hwa
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.108-108
    • /
    • 2016
  • 스마트워터그리드(Smart Water Grid; 이하 SWG)란 현재 직면에 있는 물 부족, 물 안보, 물 복지 등 물에 대한 문제를 ICT 기술을 활용하여 물관리의 새로운 패러다임을 제시할 수 있는 융합 기술이다. 즉, SWG는 기존의 수자원 관리 시스템의 한계를 극복하기 위해 첨단 정보통신기술을 이용하는 고효율의 차세대 인프라 시스템으로 다양한 수원을 활용하고 물을 효율적으로 배분 관리 운송하여 수자원의 불균형을 해소하고, 첨단센서네트워크를 이용해 용수관리 전분야에 걸쳐 양방향 실시간으로 용수정보를 감시 대응하여 용수관리와 에너지 효율의 최적화된 메가시티(mega-city)에 적합한 지능형 물관리가 가능할 것으로 예상되는 시스템이다. 따라서 국토교통부 과제로 추진중인 SWG 연구단에서 개발한 스마트 워터 기술을 영종도 112 블록에 적용하여 지역주민의 물복지 향상 및 물 사용자에 대한 소비자 만족도를 높이는데 목적을 두고 데모플랜트를 구축 방안을 수립하였다. 영종도 112블록(인천 운서동 및 운북동 일원)은 인천 공촌정수장에서 해저관로를 지나 영종통합 가압장에서 가압 후 공항신도시배수지에서 물을 공급받고 있는 지역으로 면적은 $17.41km^2$, 인구는 약 17,000명, 물사용량 $8,000m^3$/일, 총관로연장 약 55km, 유수율이 겨우 73.2% 지역이다. SWG 적용성 평가를 위해 영종도 112 블록에 유수율 제고 및 운영비용 저감을 목적으로 데모플랜트를 구축하였다. 스마트 계측을 위해 스마트미터 469개(15~20mm), 디지털미터 172개(25~200mm), 누수유무센서 1개소, 다항목 수질측정기 1개소, 유량계 3개소, 수압계 5개소, AMI 시스템 641개 및 물효율 운영프로그램과 물정보 App서비스 기능으로 구성하였다. 물효율 운영프로그램은 실시간 수요량 예측, 배수지 운영에 따른 취수량, 송수량, 펌프 대수조합 및 운전스케줄링이 가능한 경제적 물공급 스케줄링, 관망상태 감시 및 제어(실시간 유량/수압 분석을 통한 누수분석) 기능이 탑재되어 통합운영센터에서 운영할 계획이다. 데모플랜트 운영을 통해 수자원의 효율적인 배분 및 공급, 유지관리 향상, 운영 비용 최소화 등의 결과를 바탕으로 신도시 및 기존도시의 물관리 정책수립에 활용할 수 있을 뿐만아니라 시간적 공간적 불균형 해소 및 물시장 발전에 크게 기여할 것으로 사료된다.

  • PDF

Development of a pipe burst detection model using large consumer's smart water meter and pressure data (대수용가 스마트미터와 수압 데이터를 이용한 소블록 내 관 파손사고 감지모델 개발)

  • Kyoung Pil Kim;Wan Sik Yu;Shin Uk Kang;Doo Yong Choi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.521-521
    • /
    • 2023
  • 지방상수도의 관 파손사고 감지 및 누수관리 방법에는 블록시스템 구축을 통한 소블록별 야간최소유량 감시방법이 가장 대표적이다. 야간최소유량은 새벽 2시와 4시 사이의 인구 활동 비율이 가장 낮은 새벽 시간대에 소블록에 공급된 유량을 의미하며, 대부분 유량 성분은 누수량일 것이라는 가정에서 출발한다. 그러나 아파트 중심의 주거 형태를 보이는 도심지의 경우, 새벽 시간대에도 다량의 물수요가 비정기적으로 발생하고 있어 관망의 이상 여부를 감시하기 위한 관리기준으로서 야간최소유량을 이용하기에는 높은 일간 변동성에 따른 한계가 있다고 할 수 있다. 즉, 야간최소유량은 관 파손사고 발생의 감시보다는 관로 연결 또는 급수전 분기 부위에서 발생하는 미량의 누수가 수개월에 걸쳐 누적되는 장기추세를 분석하여 누수탐사반의 투입 시점을 결정하기 위한 근거를 제시하기 위한 목적으로 사용되며, 아직까지 관 파손사고의 발생은 자체적인 감지보다는 민원에 의해 인지되는 경우가 많다. 최근, 스마트관망 구축사업(SWM) 등을 통해 관 파손 및 누수 감지를 위한 청음식 누수감지센서가 소블록 내 도입되고 있으나, 초기 시설투자에 큰 비용이 수반되며 주변 소음과 배터리 전원방식의 한계로 인하여 새벽 시간대에만 분석이 제한적으로 적용되는 경우가 많아 이 역시도 상시적인 관 파손사고의 감시기술이라 보기는 어렵다. 본 연구에서는 소블록 유입점에서의 유량·압력과 소블록 내에 설치된 대수용가 스마트미터, 그리고 사고감지를 위한 수압계 사이의 평상시 수리적 균형을 학습한 DNN(Deep Neural Network) 모델을 이용하여 관 파손사고를 실시간 감지하는 모델 개발연구를 수행하였다. 모델은 관 파손사고 감지를 위한 수압계의 최적 위치와 대수를 결정하기 위한 모듈과 관 파손사고 감지모듈로 구성되며, 1개 소블록 Test-Bed를 구축하여 모델을 생성하고 PDD 관망해석 모델을 통해 생성된 가상의 사고에 대한 감지 여부로서 개발 모델의 감지성능을 평가하였다.

  • PDF

Search Method for Optimal Valve Setting and Location to Reduce Leakage in Water Distribution Networks (배수관망시스템 누수저감을 위한 최적 밸브제어 및 위치탐색 모델 개발)

  • Choi, Jong Sub;Kala, Vairavamoorthy;Ahn, Hyo Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.149-157
    • /
    • 2008
  • The reduction of leakage is a major issue of the South Korea water industry. The inclusion of pressure dependent leakage terms in network analysis allows the application of optimization techniques to identify the most effective means of reducing water leakage in distribution networks. This paper proposes a method to find optimal setting and location of control valve for reducing leakage efficiently. The proposed search method differs from previous methods for addressing optimal valve location problem and improves the GA simulation time with guaranteeing for getting the global optimal solution. The strength of this method has been demonstrated by means of case studies. This allows the procedure of optimization to be more robust and computational efficient.

Optimal design methodology of district metered area utilizing Geographic Information System (GIS를 이용한 상수관망 소블록 최적설계기법 개발)

  • Kim, Kyoung-Pil;Park, Yong-Gyun;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.2
    • /
    • pp.223-231
    • /
    • 2015
  • District Metered Area (DMA) construction is one of the most cost effective alternatives for management of water loss (i.e., water leakage) and energy consumption (i.e., water pressure) in water distribution systems. Therefore, it's being implemented to numerous new and existing water distribution systems worldwide. However, due to the complexity of water distribution systems, especially large-scale and highly looped systems, it is still very difficult to define the optimal boundary of DMAs considering all the aspects of water distribution system management requirements. In this study, a DMA design methodology (or a DMA design model) was developed with Geographic Information Systems (GIS) and hydraulic distribution system model to determine the optimal DMA boundary.

The Stability Evaluation Methods of Embankment on Soft Clay (연약지반 성토의 안정평가 방법)

  • Kang, Yea Mook;Lee, Dal Won;Kim, Ji Hoon;Kim, Tae Woo;Lim, Seong Hun
    • Korean Journal of Agricultural Science
    • /
    • v.25 no.2
    • /
    • pp.260-270
    • /
    • 1998
  • The field tests were performed to suggest the rational method for stability evaluation of soft clay. The behavior of settlement-displacement obtained by field monitoring system was to compare and analyze the results of the observationed method, and to investigate the complex behavior of soft clay with filling height. The results of this study are summarized as follows. 1. The horizontal displacement was suddenly increased when physical properties of soft clay showed maximum values and the part of the turning point. The values of these properties were available to the fundamental data for stability evaluation. The shear deformation appeared that difference of the horizontal displacement was maximum values. 2. Although the stability of embankment by step filling showed the unstable part over the failure standard line, the embankment was confirmed stable. So the evaluation of the stability of embankment is reasonable to use the inclination of curve than failure standard line. 3. The horizontal displacement and relative settlement were increased as same ratio at improvement ground. Estimation of shear deformation using Terzaghi's modified bearing capacity should consider the relations of embankment load and undrained shear strength at nonimprovement ground, and minimum safety factor is recommended to use larger than 1.2. 4. Excess pore water pressure was increased with increasing of filling height and decreased with maintain the filling height. The embankment was unstable when filling height was exceed the evaluation standard line, and the behavior of excess pore water pressure and horizontal displacement could use as a standard of judgement of the filling velocity control because their behavior were agree with each other.

  • PDF

Application of Resistivity/SP Monitoring Technique to Maintenance of Water Utilization Facilities (수리시설물의 유지관리를 위한 비저항/SP 모니터링기법 연구)

  • Park, Sam-Gyu;Kim, Jung-Ho;Seo, Goo-Won;Won, Jong-Geun;Kim, Byung-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.71-76
    • /
    • 2005
  • The subject of this paper is research into the application of resistivity/SP monitoring to detecting the water leakage of water utilization facilities. For this purpose, we installed a comprehensive monitoring system consisting of resistivity/SP measurement, inclinometer, piezometer, and water gauge at an embankment, Using this monitoring system, we monitored the various kinds of measurement data and compared the resistivity structures and SP variations that of hydrological and engineering data in order to investigate the water leakage and stability of the embankment. The variations of resistivity and SP at the embankment were provided from the monitoring data and we could accurately locate the portions of which resistivities and SP have sharply changed, Furthermore, we could estimate the stability of the embankment more effectively and quantitatively by jointly interpreting the monitoring data of resistivity and SP, water level, pore water pressure, and subsurface displacement. The monitoring experiments in this study led us to the conclusion that for the efficient maintenance of the water utilization facilities, monitoring the resistivity and SP data would be much more preferable to performing the just one-time measurements.

  • PDF

Application of Electrical Resistivity Monitoring Technique to Maintenance of Embankments (저수지의 유지관리를 위한 전기비저항모니터링 기법 응용)

  • Park Sam Gyu;Kim Jung-Ho;Seo Goo Won
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.2
    • /
    • pp.177-183
    • /
    • 2005
  • The subject of this paper is research into the application of electrical resistivity monitoring to detecting the water leakage of water utilization facilities. For this purpose, we installed a comprehensive monitoring system consisting of resistivity measurement, inclinometer, piezometer, and water gauge at an embankment. Using this monitoring system, we monitored the various kinds of measurement data and compared the resistivity structures and that of hydrological and engineering data in order to investigate the water leakage and stability of the embankment. The variant images of electrical resistivity at the embankment were provided from the monitoring data and we could accurately locate the portion of which resistivities have sharply changed. Furthermore, we could estimate the stability of the embankment more effectively and quantitatively by jointly interpreting the monitoring data of resistivity, water level, pore water pressure, and subsurface displacement. The monitoring experiments in this study led us to the conclusion that for the efficient maintenance of the water utilization facilities, monitoring the resistivity data and hydrological data would be much more preferable to performing the just one-time measurements.

Prediction of Rainfall-Induced Slope Failure Using Hotelling's T-Square Statistic (Hotelling의 T-square 통계량을 이용한 강우유발 사면붕괴 예측)

  • Kim, Seul-Bi;Na, Jong-Hwa;Seo, Yong-Seok
    • The Journal of Engineering Geology
    • /
    • v.25 no.3
    • /
    • pp.331-337
    • /
    • 2015
  • A new technique is presented to detect unstable slope behavior, based on Hotelling's T2 analysis of pore pressure and water content obtained during flume tests using granitic and gneissic weathered soils. Three sets of pore pressure-water content values were simultaneously obtained during each test, and T2 statistics at the 90.0% and 95.0% confidence levels were calculated based on the correlations between values. The results show that unsuccessful detection of some local failures of the flume slope depended on the sensor position. In the case of global slope failures, anomalous behavior was detected between several hundred and several thousand seconds before the event as T2 statistics exceeded the confidence interval 90%. Hotelling's T2 analysis provides a single control criterion because it enables correlations between diverse measured values within the same slope; the criterion also includes stepwise criteria for a forecasting and warning system based on confidence levels.

Calculation of Non-revenue Water Ratio through the Artificial Neural Network of Water Distribution System (인공신경망을 이용한 상수관망 내 무수율 산정)

  • Jang, Dong Woo;Choi, Gye Woon;Park, Hyo Seon;Jo, Hyoung Geun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.120-120
    • /
    • 2017
  • 인천지역의 상수도공급은 팔당댐을 취수원으로 하여 도수, 송수관을 거쳐 인천지역 내 정수장을 통하여 각 급수지역까지 일원화된 관로시스템으로 공급되고 있다. 관망에서의 적절한 수압관리, 노후관로 교체사업 등은 급수관망 내 관로 사고위험을 줄일 수 있고, 누수량을 저감하여 무수율의 감소로 이어질 수 있다. 상수관망 내 누수에 영향을 주는 물리적, 운영적 요소를 파악하고, 이를 이용하여 누수해결을 위한 방법론을 제시하는 것은 매우 중요하다. 본 연구에서는 인천시 배수관망 데이터를 활용하여 통계분석 및 인공신경망을 통하여 무수율에 영향을 미치는 인자를 선별하고, 무수율과의 연관성을 분석하고자 하였다. 이를 위해 대상지역에 대한 시설현황 및 운영자료를 취득하고, 무수율 분석에 활용하였다. 인천시의 소블럭을 대상으로 관로노후도, 배수관연장, 평균관경, 급수전당 공급량, 누수발생 횟수, 용도지역, 관망구성 형태 등을 고려하여 무수율과의 관계분석을 위한 통계분석을 수행하였다. 특히 급수에 필요한 최소에너지와 관망에서 공급되는 에너지를 비교하기 위하여 관망해석 프로그램인 EPANET을 이용하여 관망내 절점에서의 수압과 수요량이 적용된 최소공급에너지를 활용하였고, 이를 통하여 블록 내 과잉공급에너지와 무수율의 영향성을 비교하였다. 최종적으로 산출된 주요인자에 대한 주성분분석, 분산분석, 다중회귀분석 등의 통계분석과 인공신경망에 의해 학습된 알고리즘을 통하여 산정된 무수율을 실측 무수율과 비교, 분석하였다. 인공신경망에 의해 산정된 무수율과 실측 무수율의 정확도를 평가하기 위하여 MAE, MSE, PBIAS 등의 정확도 평가와 산점도 분석을 수행하고, 상관계수를 도출하여 가장 정확한 방법을 결정하였다. 분석 결과 통계분석에 의한 다중회귀식으로 산출된 무수율 보다 인공신경망에 의한 무수율이 실측값에 더욱 근접한 것으로 나타났으며 이용된 뉴런의 수의 따라 산출결과가 상이하기 때문에 최적 뉴런의 수를 산정해야 할 필요가 있음을 확인하였다. 특히 사용된 상수관망 주요인자 중 주성분분석을 통하여 선정된 각 성분을 인공신경망에 적용시 더욱 정확한 무수율 예측이 가능한 것으로 나타났다.

  • PDF