• Title/Summary/Keyword: 수심유지효과

Search Result 42, Processing Time 0.017 seconds

The Study of Operating Conditions by Establishing Density Currents Generator for Improving of Water Quality on Lake Water - With Focus on DO and Water Temperature - (호소수의 수질개선을 위한 DCG 설치시 운전조건에 관한 연구 - DO와 수온을 중심으로 -)

  • Lee, Young-Shin;Han, Kyung-Hee;Kim, Young-Kyu;An, Hyung-Chul;Shin, Sung-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.286-294
    • /
    • 2014
  • The purpose of this study is to investigate the effects of applying density current generator (hereafter referred to as DCG to large lakes on the operating conditions of DCG, de-stratification, water quality improvement and inhibition of algae occurrence. As a result of a survey conducted to derive the optimum operating parameters of DCG in a condition to minimize eco-toxicity, the following conclusions were obtained. During the survey period, a marked stratification appeared in September to October 2011 and May 2012. At this time, the average depth of water to form thermocline was found to be $5{\pm}2$ m, so the location of discharge port for the operation of DCG was determined to be about 5 m below from the surface. To minimize the adverse effects of benthos and obtain the effect of water mixture at the time of water circulation, the mixing ratio of surface water and deep water was designed to be 3:1 by means of ecotoxicological assessment on the DCG operating characteristics. To select the appropriate operating hours for DCG, DCG was operated by 12 hr, 24 hr, 36 hr and 48 hr. As its result, the formation of thermocline did not occur during the operation of 36 hr. Also, It was effected that start reoperating from 3rd day after stop 2days under the condition of operated during 36 hr with calculated power consumption. Under the above conditions, the results of DO and water temperature analysis during the operation of DCG showed that the stratification, which was distinct previously, appeared to be weak, and relatively lower levels than those before operation were found as a result of water quality analysis on COD and chlorophyll-a, which leads to the conclusion that the water body is maintained at a stable condition due to the circulation of water by the occurrence of density current resulting from the operation of DCG.

Preservation of Washed Fresh Ginsengs by Gamma Irradiation (방사선(放射線) 조사(照射)에 의한 수세된 수삼(水蔘)의 저장(貯藏))

  • Cho, Han-Ok;Byun, Myung-Woo;Kwon, Joong-Ho;Lee, Jae-Won
    • Applied Biological Chemistry
    • /
    • v.29 no.3
    • /
    • pp.288-293
    • /
    • 1986
  • The washed fresh ginsengs packed with air, vaccum and nitrogen gas were irradiated at the levels of 1,2 and 3kGy gamma radiation and then stored at $4{\sim}5^{\circ}C$ for 90days to investigate the effects of gamma radiation on microbial inactivation, eelworm disinfestation and physicochemical changes. After a 90 day storage, $2{\sim}3kGy$ irradiated groups showed 20% of weight loss and 10% of rot while non-irradiated group 100% and 20% or more, respectively. Also the irradiated groups showed somewhat lower values of specific gravity, color density and hardness immediately after irradiation, thereafter higher value of them with storage time than those of non-irradiated group. The irradiation increased the yields of ginseng extract and crude saponins but no effects on the proximate composition and TLC and HPLC patterns of saponin. The food-borne microorganisms decreased in viable cell counts by $2{\sim}3$ log cycles with $2{\sim}3kGy$ radiation and the eelworms were completely disinfested with 1 kGy radiation.

  • PDF