• Title/Summary/Keyword: 수소 충전 시스템

Search Result 60, Processing Time 0.035 seconds

A Numerical Analysis of Pressure Distribution and Pressure Drop in Receptacle for Hydrogen Charging System (수소 충전 시스템용 리셉터클의 내부 압력 분포와 압력 강하에 관한 수치적 연구)

  • YUANGANG WANG;SEUNGHYEOK LEE;CHAE HOON SOHN;SEDONG LEE;HYUNBOK LEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.5
    • /
    • pp.497-504
    • /
    • 2023
  • This study analyzes pressure distribution and pressure drop in the receptacle used in charging system of hydrogen fuel cell vehicles. The objective is to minimize receptacle-induced pressure drop by redesigning internal flow channels. Through numerical simulations, three receptacle variants are compared with a baseline case. Results show reduced pressure drop in the filter section. However, the check valve section exhibits higher pressure drop, requiring further improvement. By increasing throat diameter, pressure drop is decreased by 28% between inlet and outlet of the receptacle. This study shows the relationship between dynamic pressure and pressure drop, providing a guideline for receptacle performance optimization. The redesigned receptacle offers potential for enhancing hydrogen charging efficiency.

An Analysis of Accessibility to Hydrogen Charging Stations in Seoul Based on Location-Allocation Models (입지배분모형 기반의 서울시 수소충전소 접근성 분석)

  • Sang-Gyoon Kim;Jong-Seok Won;Yong-Beom Pyeon;Min-Kyung Cho
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.2
    • /
    • pp.339-350
    • /
    • 2024
  • Purpose: This study analyzes accessibility of 10 hydrogen charging stations in Seoul and identifies areas that were difficult to access. The purpose is to re-analyze accessibility by adding a new location in terms of equity and safety of location placement, and then draw implications by comparing the improvement effects. Method: By applying the location-allocation model and the service area model based on network analysis of the ArcGIS program, areas with weak access were identified. The location selection method applied the 'Minimize Facilities' method in consideration of the need for rapid arrival to insufficient hydrogen charging stations. The limit distance for arrival within a specific time was analyzed by applying the average vehicle traffic speed(23.1km/h, Seoul Open Data Square) in 2022 to three categories: 3,850m(10minutes), 5,775m(15minutes), 7,700m(20minutes). In order to minimize conflicts over the installation of hydrogen charging stations, special standards of the Ministry of Trade, Industry and Energy applied to derive candidate sites for additional installation of hydrogen charging stations among existing gas stations and LPG/CNG charging stations. Result: As a result of the analysis, it was confirmed that accessibility was significantly improved by installing 5 new hydrogen charging stations at relatively safe gas stations and LPG/CNG charging stations in areas where access to the existing 10 hydrogen charging stations is weak within 20 minutes. Nevertheless, it was found that there are still areas where access remains difficult. Conclusion: The location allocation model is used to identify areas where access to hydrogen charging stations is difficult and prioritize installation, decision-making to select locations for hydrogen charging stations based on scientific evidence can be supported.

State of Charge Calculation Using a Differential Amplifier On the Batteries (차동 증폭회로를 적용한 축전지 잔존용량산정)

  • Jo, Kyu-Pan;Moon, Chae-Joo;Kim, Tae-Gon;Chae, Sung-Yeol;Jeong, Moon-Seon;Lee, Kyung-Sung
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.557-558
    • /
    • 2011
  • 전기자동차의 축전지 관리 시스템(BMS : Battery Management System)의 잔존용량(SOC : State Of Charge)산정에는 Ah 측정법, 비중측정법, 전압측정법 등이 있다. 기존 전압 측정법의 경우 측정 전압을 프로세서에서 직접 처리하기 때문에 축전지의 미세한 전압 변화를 측정하지 못하여 잔존 용량 산정시 세밀한 계산에 어려움이 따른다. 본 논문에서는 축전지의 전압 측정 시 프로세서 전단에 전압의 부분 증폭회로를 추가하여 축전지의 미세한 전압변화를 증폭하여 측정하는 방법을 제안 하였다. 니켈수소전지를 대상으로 실험한 결과 충전 중 기존 전압측정법은 1.431V, 1.436V, 1.441V가 측정 되었을 때의 잔존 용량은 84%로 일정하였다. 같은 전압변화에서 부분증폭회로를 적용한 충전전압은 1.4297V, 1.4303V ~ 1.4352V, 1.4358V로 측정 되었으며, 그에 따른 잔존용량은 84% ~ 85%로 기존 전압 측정법 보다 약 9 ~ 10배 정도 세밀하게 측정 되었다. 제안한 방법을 통한 실험으로 제안된 방법이 기존 전압 측정법보다 세밀한 전압 측정 및 SOC산정이 가능함을 확인 하였다.

  • PDF

A Study on SOC Algorithm and Design of Battery ECU for Hybrid Electric Vehicle (하이브리드 전기자동차용 배터리 ECU 설계 및 잔존용량 알고리즘에 관한 연구)

  • 남종하;최진홍;김승종;황호석;김재웅
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.319-325
    • /
    • 2004
  • The major factors that make ZEV affordable are the range and cost. The development of advanced batteries such as Ni-MH battery can solve the problem partly; on the hand the battery management system is an efficient way. Ni-MH battery and battery ECU is a key component influencing ZEV performance, such as range, acceleration and hill-climbing capability. Because most problems related to battery such as short circuit, over-discharge and overcharge occur easily during operation, it is necessary to develop a dedicated battery ECU for HEV. This paper proposes a new SOC algorithm for the HEV based on the terminal voltage and current integration. And battery ECU was designed and analyzed. Also, the validity is confirmed through experiment.

Process Simulation of HCNG Refueling System (HCNG 충전 시스템 공정모사)

  • Kim, Sang-Min;Han, Jeong-Ok;Lee, Yeong-Cheol;Lee, Joong-Seong;Kim, Yong-Cheol;Chae, Jeong-Min;Hong, Seong-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.5
    • /
    • pp.1-7
    • /
    • 2013
  • In this study, simulation work of HCNG refueling system was performed. The hydrogen was produced from steam reforming process by natural gas. The conversion of natural gas is increased as SCR is increased. but it was no significant difference more than 3 of SCR and fuel throughput is increased as GHSV is increased. Both conversion and fuel throughput levels was optimized when the $1700h^{-1}$ of GHSV. CNG was compressed from low pressure natural gas. For the mixing of $H_2$ and CNG is mixed with the high pressure conditions such as 400bar of $H_2$ and 250bar of natural gas. Single-stage compression was required more power than multi stage. So, multi stage compression was suggested for high pressure compression. We calculated the intermediate pressure to minimize total required power of compressors. The intermediate pressure for $H_2$ and natural gas were derived at 61 and 65 bar, respectively.

FPGA based POS MPPT control for a small scale charging system of PV-nickel metal hydride battery (FPGA를 이용한 소형 태양광 발전 니켈 수소 전지 충전 시스템의 POS MPPT 제어)

  • Lee, Hyo-Geun;Seo, Hyo-Ryong;Kim, Gyeong-Hun;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1306-1307
    • /
    • 2011
  • Recently, the small scale photovoltaic (PV) electronic devices are drawing attention as the upcoming PV generation system. The PV system is commonly used in small scale PV applications such as LED lighting and cell phone. This paper proposes photovoltaic output sensorless (POS) maximum power point tracking (MPPT) control for a small scale charging system of PV-nickel metal hydride battery using field-programmable gate array (FPGA) controller. A converter is connected to a small scale PV cell and battery, and performs the POS MPPT at the battery terminal current instead of being at the PV cell output voltage and current. The FPGA controller and converter operate based on POS MPPT method. The experimental results show that the nickel metal hydride battery is charged by the maximum PV output power.

  • PDF

A study on the safety assessment of Hydrogen refueling system (수소 충전 시스템의 안전성 평가에 관한 연구)

  • Kim, Tae Hun;Oh, Young Dal;Lee, Man Soo
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.167-173
    • /
    • 2014
  • Hydrogen energy is expanding in range for civil use together with development of pollution-free power sources recently, and it is judged that the use of hydrogen will increase more as a part of carbon dioxide reduction measures according to the Climatic Change Convention. Especially, it is thought that the securement of safety of the used dispenser will be the biggest obstacle in the use of high-pressure hydrogen because the hydrogen station is operated in a high pressure. This study found risks in the process and problems on operation by making use of HAZOP(6 kinds), a qualitative safety evaluation technique, and FMEA(5 kinds), a fault mode effect analysis, for the hydrogen charging system at a hydrogen gas station, derived 6 risk factors from HAZOP and 5 risk factors from FMEA, and prepared measures for it.

FPGA based POS MPPT Control for a Small Scale Charging System of PV-nickel Metal Hydride Battery (FPGA를 이용한 소형 태양광 발전 니켈 수소 전지 충전 시스템의 POS MPPT 제어)

  • Lee, Hyo-Guen;Seo, Hyo-Ryong;Kim, Gyeong-Hun;Park, Min-Won;Yu, In-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.80-84
    • /
    • 2012
  • Recently, the small scale photovoltaic (PV) electronic devices are drawing attention as the upcoming PV generation system. The PV system is commonly used in small scale PV applications such as LED lighting and cell phone. This paper proposes photovoltaic output sensorless (POS) maximum power point tracking (MPPT) control for a small scale charging system of PV-nickel metal hydride battery using field-programmable gate array (FPGA) controller. A converter is connected to a small scale PV cell and battery, and performs the POS MPPT at the battery terminal current instead of being at the PV cell output voltage and current. The FPGA controller and converter operate based on POS MPPT method. The experimental results show that the nickel metal hydride battery is charged by the maximum PV output power.

Satellite Battery Cell Voltage Monitor System Using a Conventional Differential Amplifier (종래의 차동증폭기를 사용한 인공위성 배터리 셀 전압 감시 시스템)

  • Koo, Ja-Chun;Choi, Jae-Dong;Choi, Seong-Bong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.2
    • /
    • pp.113-118
    • /
    • 2005
  • This paper shows a satellite battery cell voltage monitor system to make differential voltage measurements when one or both measurement points are beyond voltage range allowed by a conventional differential amplifier. This system is particularly useful for monitoring the individual cell voltage of series-connected cells that constitute a rechargeable satellite battery in which some cell voltages must be measured in the presence of high common mode voltage.

Preparation and characterization of poly(dimethylsiloxane) foam prepared by hydrogen condensation reaction (수소 축합 반응에 의한 폴리디메틸실록산 미세 발포체의 제조 및 물성분석 연구)

  • Lee, Soo;Moon, Sung Jin
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.4
    • /
    • pp.802-812
    • /
    • 2016
  • Silicone foam is very useful as flame resistant material for many industrial areas such as high performance gasketing, thermal shielding, vibration mounts, and press pads. A silicone foam was prepared through simultaneous crosslinking and foaming by hydrogen condensation reaction of a vinyl-containing polysiloxane (V-silicone) and a hydroxyl-containing polysiloxane (OH-silicone) with hydride containing polysiloxane (H-silicone) in the presence of platinum catalyst and imorganic filler at room temperature. This is more convenient process for silicone foam manufacturing than the conventional separated crosslinking and foaming systems. Funtionalized silicones we used in this experiment were consisted with a V-silicone containing 1,0 meq/g of vinyl groups and a viscosity of 20 Pa-s, an OH-silicone with 0.4 meq/g of hydroxyl groups and a viscosity from 50 Pa-s, and an H-silicone containing 7.5 meq/g of hydride groups and a viscosity of 0.06 Pa.s. The effects of compositions of functionalized silicones and additives, such as catalyst and filler on the structure and mechanical properties of silicone foam were studied. 0.5 wt% of Pt catalyst was enough to accelerate the foaming rate of silicone resins. The addition of OH-silicone with lower viscosity accelerates the initial foaming rate and decreases the foam density, but the addition of V-silicone with lower viscosity reduces the tensile strength as well as the elongation. The final foam density, tensile strength, and elogation of silicone foam prepared under the SF-3 condition increase maximum to $0.58g/cm^3$, $3,51kg_f/cm^2$, and 176 %, repectively. We found out the filler alumina also played an important role to improve the mechanical properties of silicone foams in our foaming system.