• Title/Summary/Keyword: 수소저장 용기

Search Result 90, Processing Time 0.026 seconds

A Study on the Characteristics of Temperature Distribution Related to Geometry of Tube in Hydrogen Storage Vessel (수소 저장용 탱크의 튜브 형상에 따른 온도분포 특성에 대한 수치해석 연구)

  • OH, SEUNG JUN;YOON, JEONG HWAN;JEON, KYUNG SOOK;KIM, JAE KYU;PARK, JOON HONG;CHOI, JEONGJU
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.4
    • /
    • pp.205-211
    • /
    • 2021
  • Recently, it is necessary for study on renewable energy due to environmental pollution and fossil fuel depletion. Therefore, in this study, the filling temperature according to the nozzle geometry was evaluated based on the limit temperature specified in SAEJ2601 for charging hydrogen, a new energy. There are three types of nozzles, normal, angle and round, fixed the average pressure ramp rate at 52.5 MPa/min, and the injection temperature was set at 293.4 K. As a result, the lowest temperature distribution was found in the round type, although the final temperature did not differ significantly in the three types of nozzles. In addition, Pearson's coefficient was calculated to correlate the mass flow rate with the heat transfer rate at the inner liner wall, which resulted in a strong linear relationship of 0.98 or higher.

Strength Safety Study on the Stress Characteristics of a Composite Pressure Cylinder for 35MPa Hydrogen Gas Vehicle (35MPa 수소가스 자동차용 복합소재 압력용기의 응력특성에 관한 강도안전성 연구)

  • Kim, Chung-Kyun;Kim, Do-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.2
    • /
    • pp.25-30
    • /
    • 2012
  • This paper presents a stress safety of a composite pressure cylinder in which is composed of an aluminum liner and composite layers with carbon fiber/epoxy and glass fiber/epoxy resigns. The composite pressure cylinder for a hydrogen gas vehicle contains 9.2 liter hydrogen gas, and hydrogen gases are compressed by a filling pressure of 35MPa. The FEM computed results are analyzed based on the US DOT-CFFC basic requirement for a hydrogen gas cylinder and KS B ISO specification. The FEM results indicate that the stress, 247MPa of an aluminum liner is sufficiently low compared with that of 272MPa, which is 95% level of a yield stress for aluminum. And, the carbon fiber composite layers in which are wound on the surface of an aluminum cylinder are safe because the maximum carbon fiber stresses from 29.43% to 28.87% in hoop and helical directions are below 30% for a given minimum required burst pressure level, respectively. The carbon fiber composite layers are also safe because the stress ratios from 3.40 to 3.46 in hoop and helical directions are above 2.4 for a minimum safety level, respectively.

Numerical Analysis of Fillling Flow in Type III Hydrogen Tank with Different Turbulence Models (Type III 수소 저장 용기에서 난류 모델(Turbulence Model)에 따른 충전(Filling)현상의 수치 해석적 연구)

  • KIM, MOO-SUN;RYU, JOON-HYOUNG;LEE, SUNG-KWON;CHOI, SUNG-WOONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.6
    • /
    • pp.483-488
    • /
    • 2021
  • With continuous emission of environmental pollutants and an increase in greenhouse gases such as carbon dioxide, demand to seek other types of energy sources, alternative energy, was needed. Hydrogen, an eco-friendly energy, is attracting attention as the ultimate alternative energy medium. Hydrogen storage technology has been studied diversely to utilize hydrogen energy. In this study, the gas behavior of hydrogen in the storage tank was numerically examined under charge conditions for the Tpe III hydrogen tank. Numerical results were compared with the experimental results to verify the numerical implementation. In the results of pressure and temperature values under charge condition, the Realizable k-ε model and Reynold stress model were quantitatively matched with the smallest error between numerical and experimental results.

A Study on the Development of the High Rate Zinc-Silver Oxide Primary Battery (고율 아연-산화은 1차전지의 개발에 관한 연구)

  • 김세웅;공영경
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1994.05a
    • /
    • pp.114-117
    • /
    • 1994
  • 아연-산화은 전지는 높은 에너지 및 전력밀도를 가지고 있으나 비싼 제작비용 때문에 우주항공, 군사무기 등 특수한 분야에서 주로 이용되며, 특히 전해액이 별도의 용기에 보관되어 있다가 외부 신호에 의해 충전된 dry상태의 전지에 주입되어 활성화되는 1차 또는 비축형 아연산화은 전지는 우수한 고율방전 특성, 장시간의 저장기간 및 활성화와 동시에 부하를 인가 할 수 있는 특성 때문에 많은 무기체계에서 이용하고 있다. 이러한 아연-산화은 전지의 아연전극은 높은 다공도와 반응 면적을 가져야 하며, 특히 방전중 아연전극의 전위는 가역 수소전위 보다 더 음전위이기 때문에 수소가스가 다량 발생하게 되므로 수은과 같은 높은 과전압을 갖는 물질을 첨가하여 가스 발생량을 줄이고 부동태화(passivation)를 억제하게 된다. 그러나 국내 여건상 수은을 사용하여 전지를 제작하는 것은 환경문제 등으로 인하여 어렵기 때문에 본 연구에서는 수은을 사용하지 않고 비축형 아연-산화은 전지의 음극판을 제작하기 위하여 전착법(electro deposit)과 mesh 제작방법을 혼합하여 아연전극을 제작하였으며, 기판에 석출된 아연과 아연 mesh의 질량비율에 따른 전지의 성능을 평가하였다.

  • PDF

Effect of Methodologies for Laser-Induced Plasma Creation on Hydrogen Sensing (레이저 유도 플라스마 생성 방법이 수소 검출에 미치는 영향)

  • Jang, Jung-Ik;Kim, Ki-Bum
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.4
    • /
    • pp.291-297
    • /
    • 2015
  • As promising future energy source, hydrogen has been drawing much attention; however, it is easily leaked from the small gap in any storage container due to its find molecule size. In this study, Laser induced breakdown spectroscopy(LIBS) was used for hydrogen leak detection, and feasibility of the scheme was evaluated based on different way for plasma generation. Laser power of 295 mW was required for generating plasma on metal surface to measure hydrogen atomic emission while approximately 2.5 times higher laser power was needed for plasma formation directly in the hydrogen gas stream. It was shown that peak to base ratio increased linearly with increasing the concentration of hydrogen. It can be concluded that LIBS is a viable technique for hydrogen sensing when the concentration of hydrogen is less than 5%.

A Study on the Structural Safety Analysis of Neck Mount Block of Type 4 Hydrogen Storage Vessel by Finite Element Method (유한요소법을 이용한 type 4 수소저장용기용 고정 장치의 구조적 안전성 분석에 관한 연구)

  • GUNWOO KIM;HYEWON KIM;HANMIN PARK;JEONGHO LEE;SUJIN YOON;HANSU LEE;JOUNGLYUL KIM;SEOKJIN LEE;GYEHYOUNG YOO;YOUNGGIL YOUN;HANSANG KIM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.35 no.2
    • /
    • pp.195-204
    • /
    • 2024
  • The study involves a finite element analysis to evaluate the structural integrity of the neck mount block for a type 4 hydrogen storage vessel, with the aim of enhancing its strength and rigidity. The existing neck mount block consists of a fixed part and a sliding part, each comprising a body block for load support, a screw part for neck boss fixation, and bolts. To analyze the vulnerabilities of the neck mount block under bolt fastening and load conditions relative to vehicle travel directions, a structural analysis process was developed. Comparative analysis between the enhanced design and the existing model was performed, resulting in improved strength and rigidity. The objective is to provide guidance for the current product development and to offer fundamental data for the design and structural analysis of future development projects.

Tritium Fuel Cycle of the International Thermonuclear Experimental Reactor (국제핵융합실험로 삼중수소 연료주기)

  • Song, Kyu-Min;Sohn, Soon Hwan;Chung, Hongsuk;Yun, Sei-Hun;Jung, Ki Jung
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.595-603
    • /
    • 2012
  • International Thermonuclear Experimental Reactor (ITER) will be constructed in 2019 according to the JIA (Joint Implementation Agreement) of 7 countries. The ITER fusion fuel cycle consists of fusion vacuum vessel, tritium plant and fuelling system. The tritium plant provides the functions of storage, delivery, separation, removal and recovery of the deuterium and tritium used as fusion fuels for the ITER. The tritium plant systems supply deuterium and tritium from external sources and treat all tritiated fluids from ITER operation through Storage and Delivery System (SDS), Tokamak Exhaust Processing (TEP), Isotope Separation System (ISS), Water Detritiation System & Atmosphere Detritiation System (WDS & ADS) and Analysis System (ANS). In this paper, the functions and design requirements of the major systems in the tritium plant and the status of R&D are described. Korean party is developing the SDS for ITER tritium plant and partially attaining the WDS technology through the construction and operation experience of the Wolsong Tritium Removal Facility (WTRF). Now it is expected that researchers in other fields such as chemical engineering take part in the development of upcoming technologies for ISS and TEP.

Thermal analysis of a LH2 storage for vehicles (자동차용 액체수소 저장 용기의 열해석)

  • Oh, Byeong Soo;Jung, Jin Sam
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.10 no.3
    • /
    • pp.151-157
    • /
    • 1999
  • The development of hydrogen vehicles has been actively progressed in the developed countries such as U. S., Japan and Germany. The most important technology of using hydrogen fuel is to develope a compatible storage tank with respect to the fossil fuel tank. Among many storage methods, the liquid hydrogen is the most desirable state because of the lowest volume and weight. The metal hydride tank is too heavy and the compressed hydrogen tank is too bulky. Because of these reasons, it is the principal purpose to analyze the theoretical heat transfer for designing and manufacturing an actual $LH_2$ tank. The insulation methods of the room between inner and outer vessel are non-vacuum, vacuum, vacuum with MLI(Multi-Layer Insulation). According to the results of the numerically calculated heat leak through the walls of the $LH_2$ tank, the vacuum insulated tank has 20 times and the MLI tank has 5616 times less heat leak than the non-vacuum tank.

  • PDF

A Study on the Quantitative Risk Assessment of Hydrogen-LPG Combined Refueling Station (수소-LPG 복합충전소 정량적 위험성평가에 관한 연구)

  • Kang, Seung Kyu
    • Journal of Energy Engineering
    • /
    • v.28 no.4
    • /
    • pp.29-34
    • /
    • 2019
  • In this study, a quantitative risk assessment was carried out for a hydrogen complex station. The complex fueling station to be evaluated was hydrogen-LPG, and the components of each station were analyzed and the risk was evaluated. The final risk is assessed by individual and societal risks, taking into account the impact of damage and the frequency of accidents. As a result of individual risk calculation for the hydrogen-LPG fueling station that is the subject of this study, the hydrogen-LPG type fueling station does not show the unacceptable hazardous area (> 1 × 10E-3) proposed by HSE. The level of individual risk for both the public and the worker is within acceptable limits. In societal risk assessment, the model to be interpreted shows the distribution of risks in an acceptable range(ALARP, As Low As Reasonably Practicable). To ensure improved safety, we recommend regular inspections and checks for high-risk hydrogen reservoirs, dispensers, tube trailer leaks, and LPG vapor recovery lines.

Study on the Stability of NaBH4 Solution during Storage Process (NaBH4수용액 저장과정 중 안정성에 관한 연구)

  • Sim, Woojong;Jo, Jaeyoung;Choi, Daeki;Nam, Sukwoo;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.48 no.3
    • /
    • pp.322-326
    • /
    • 2010
  • Stability of sodium borohydride solution during storage was studied. In order to enhance the $NaBH_4$ stability, NaOH and KOH were added to the $NaBH_4$ solution. The effect of concentration of the borohydride and alkaline solution, temperature and materials of storage vessels on the rate of borohydride hydrolysis was investigated. The rate of hydrogen evolution decreased as the concentration of alkaline increased due to increase of $NaBH_4$ stability in the solution. The stability of $NaBH_4$ solution decreased when the borohydride concentration raised from 10 to 15 wt% and then increased when the $NaBH_4$ concentration increased above 15 wt% due to increase in the pH of the concentrated solution. The activity coefficient of hydrolysis of $NaBH_4$ solution(NaOH 3.0 wt%, $NaBH_4$ 25 wt%) was 115.1 kJ/mol and this value was 1.5~4.0 times higher than that of hydrolysis of $NaBH_4$ solution with catalyst. The borohydride solutions in glass and stainless-steel vessel were more stable than the solution in plastic(PE) vessel.