Risk Assessment and Its Application for the POSCO's Batch Annealing Furnace Gas Systems (광양제철소 소둔로 가스설비에 대한 위험성 평가 및 안전성향상안 제시)

  • Kim Y. S.;Yoo J. H.;Jeong S. Y.;Jang E. J.
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.2 s.14
    • /
    • pp.9-13
    • /
    • 2001
  • A complete spectrum of risk assessment including qualitative and quantitative approaches were performed for the POSCO's Batch Annealing Furnace (BAF) gas systems. The purpose of BAF is to enhance the quality of steel by annealing it with either hydrogen/nitrogen mixture gas or pure hydrogen gas. Number of gas leak scenarios were identified to generate frequency of their occurrences. With the hypothetical accident scenarios given, fire/explosion impact studies were performed to estimate magnitude of significant consequences. Several different indices were also presented from which practical safety improvement action items could be established.

  • PDF

An Investigation of Hazard Distance in a Series of Hydrogen Jet Fire with the Hyram Tools (수소 누출 시 제트화재 피해 범위에 대한 분석)

  • KANG, BYOUNG WOO;LEE, TAECK HONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.2
    • /
    • pp.166-173
    • /
    • 2017
  • For commercialization of hydrogen refuelling station (HRS), we need to reduce the clearance distance for jet fire in the real entities in the HRS. Thus, we revisited the current regulations of clearance distance for jet fire in the law. The law in korea has been set up by replica of japan, not by our own scientific basis. Recently, sandia lab developed Hydrogen Risk Assessment Model (HyRAM) tools and we simulated a series of circumstances such as 10 to 850 bar with several leak hole sizes. In 850 bar with 10 mm diameter hole leak cases, it shows $4,981kW/m^2$ at 12 m separation from leak source and $1,774kW/m^2$ at 17 m separation from leak source. In 850 bar with 1 mm diameter leak hole, it shows $0.102kW/m^2$ at 12 m separation and $0.044kW/m^2$ at 17 m separation. Current law may be acceptable with 1 mm hole size with 850 bar.

Safety Analysis of Potential Hazards at Hydrogen Refueling Station (수소충전소 잠재적 위험에 대한 안전성해석)

  • Park, Woo-Il;Kim, Dong-Hwan;Kang, Seung-Kyu
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.4
    • /
    • pp.43-48
    • /
    • 2021
  • This study was conducted using FLACS, a specialized gas accident analysis program. Hydrogen refueling stations subject of safety analysis, consist of compression facilities, storage tanks, and hydrogen piping. The safety analysis of potential risk factors was conducted after reflecting the design specifications of major facilities and components, environmental conditions around hydrogen refueling stations, etc. As of 2021, about 70 refueling stations in Korea are available, and 1,200 are scheduled to be introduced in the next 2040. To prepare for possible accidents caused by potential hazards for the safe distribution of hydrogen refueling stations, we intend to derive hydrogen leakage diffusion scenarios and review their safety.

A Basic Study for the Performance Evaluation of a Raman LiDAR Detector for Detecting Hydrogen Gas (수소 가스 검출용 라만 라이다 측정기의 성능 평가를 위한 기초 연구)

  • WONBO CHO;YUNKYU LIM;YANGKYUN KIM;BYOUNGJIK PARK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.2
    • /
    • pp.205-211
    • /
    • 2023
  • Hydrogen gas is light and diffuses very quickly. Therefore, when a leakage accident occurs, the damage is great, so a technology that can quickly measure the leakage in the air at a long distance is needed. In order to develop hydrogen gas leaked in the atmosphere in a non-contact manner, an experiment was performed to measure hydrogen gas using a lidar technology using the Raman effect. Hydrogen Raman signals were detected using a UV LED light source, which is a Raman light source, and a spectrometer in the ultraviolet region including an optical filter in the 400-430 nm band. To develop this, a Raman lidar optical structure was designed to measure the hydrogen Raman signal at a certain distance, and the hydrogen Raman spectrum was confirmed using a standard gas to evaluate the performance of this optical structure. The linearity was found to be 0.99 using hydrogen standard gas (10, 50, 100, 500, 1,000 ppm). Accordingly, a Raman lidar capable of measuring hydrogen gas rapidly diffusing in the air in an open state was developed to improve the limitations of existing hydrogen sensors.

A Study on the Development of Calculation Tables and Formulas for Determining Separation Distance in Case of Cl2・HF Tank-lorry Leakage (염소・불화수소 탱크로리 누출사고 시 이격거리 산정을 위한 산정표 및 산정식 개발 연구)

  • Jeon, Byeong-Han;Kim, Hyun-Sub;Lim, Sang-Min;Lee, Joo-Chan;Lee, Gang-San
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.212-219
    • /
    • 2021
  • Chemical accidents caused by transport vehicles account for 20% of all chemical accidents every year, but there are difficulties in the accident-response process due to repeated situations where the impact assessment information is unknown. In this study, we developed a calculation table and formula for predicting the range of damage for chlorine and hydrogen fluoride, which have a high domestic usage, high risk of accidents, and high accident frequency in the last 7 years. The calculation table is based on the leakage rate, wind speed, and temperature, and the calculation formula was derived using R software for special situations where it is difficult to apply the calculation table. The calculation table and formula could be used on site by related organizations to obtain important information for decision making, which could help in minimizing damage from chemical accidents, setting separation distances, and deciding to evacuate residents.

Risk Assessment for Performance Evaluation System of Hydrogen Refueling Station (수소충전소 성능평가 장비 안전성 평가 연구)

  • KANG, SEUNGKYU;LEE, DONGHOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.3
    • /
    • pp.232-239
    • /
    • 2022
  • This study performed qualitative and quantitative risk assessment of equipment for evaluating the protocol of hydrogen refueling stations and suggested measures to improve safety. Hazard and operability study was performed for qualitative risk assessment, and Hy-KoRAM was used for quantitative risk assessment. Through a qualitative risk assessment, additional ventilation devices were installed, simultaneous venting of the storage container was prohibited, and the number of repeated refilling of the evaluation equipment was identified to manage the number of fillings of the container. Through quantitative risk assessment, the area around the device was set as a restricted area when evaluating the station, and measures were suggested to reduce the frequency of accidents.

OVERVIEW OF HEALTH PHYSICS STUDIES ON TRITIUM BETA RADIATION (삼중수소 베타방사선에 관한 보건물리 연구의 적용)

  • Hwang, Sun-Tae;Hah, Suk-Ho
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.75-85
    • /
    • 1994
  • As we enter the 2000s, there are four nuclear power units of the pressurized heavy water reactor-type in the commercial operation at the Wolsung Nuclear Power Plant(NPP) site where a larger amount of tritium ($\^$3/H) is released inevitably to the site environment. This radioctive nuclide is easily distributed throghout our environment because of its ubiquitous form as tritiated water (HTO) and its persistence in the environment. Tritum has certain characterisitics that present unique challenges for beta radiation dosimety and health risk assesment. In this paper, therefore, a variety of matters on tritium are considered and reviewed in terms of its characteristics and sources, metabolism and dosimetry, microdosimetry, radiobiology, risk assessment, and transport and cycling in the environment, etc.

  • PDF

이동식 진공 배기장치를 이용한 하나로 냉중성자원 가스블랭킷계통의 기능시험

  • Jeong, Chang-Yong;Lee, Su-Cheol;Park, Guk-Nam;U, Sang-Ik;Kim, Yeong-Gi
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.330-330
    • /
    • 2010
  • 하나로 노심에서 발생하는 열중성자를 감속재인 액체수소층을 통과시켜 냉중성자를 생산 하는 설비인 냉중성자원 시설은 초경량 합금, 신소재 및 DNA 구조연구 등의 첨단기술연구에 유용한 도구로 활용될 계획이며, 현재 원자력연구원에서는 냉중성자원 시설을 개발하여 제작 설치하였고, 이 장치들에 대해 기능시험을 수행하였다. 냉중성자원 시설계통에서 가스블랭킷계통은 수소의 외부누출을 방지하고, 진공용기를 포함한 수조내기기 내부로 공기 및 경수가 유입되지 않도록 하여 냉중성자원을 보호하기 위한 역할을 수행한다. 또한 가스블랭킷계통의 구성은 가스공급장치($N_2$ 및 He 가스 실린더로부터 가스공급 기능), 질소충압탱크, 진공박스, 수소박스, 밸브박스 및 각 구역별 독립 배관 등으로 되어있다. 이동식 진공배기장치는 가스블랭킷계통에서 사용하기 위해 특수하게 제작된 장치로서 진공계통과 수소계통의 초기충진 시 또는 계통배기 시 잔류가스를 제거하거나, 블랭킷가스의 오염검사를 위한 시료채취 기능 등을 수행할 수 있도록 되어있다. 본 논문에서는 냉중성자원장치 내의 수소계통 및 진공계통의 배관과 기기를 외기와 경수로부터 안전하게 격리시키기 위해서 제작설치 적용된 가스블랭킷계통에서 이동식 진공배기장치를 이용하여 잔류가스 제거방법과 각 가스블랭킷 영역으로부터 시료를 채취하여 수행된 산소농도 분석에 대해 기술하였다.

  • PDF

Analysis of Safety by Expansion of Hydrogen Charging Station Facilities (수소충전소 설비 증설에 따른 안전성 해석)

  • Park, Woo-Il;Kang, Seung-Kyu
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.6
    • /
    • pp.83-90
    • /
    • 2020
  • This study conducted a risk assessment using the HyKoRAM program created by international joint research. Risk assessment was conducted based on accident scenarios and worst-case scenarios that could occur in the facility, reflecting design specifications of major facilities and components such as compressors, storage tanks, and hydrogen pipes in the hydrogen charging station, and environmental conditions around the demonstration complex. By identifying potential risks of hydrogen charging stations, we are going to derive the worst leakage, fire, explosion, and accident scenarios that can occur in hydrogen storage tanks, treatment facilities, storage facilities, and analyze the possibility of accidents and the effects of damage on human bodies and surrounding facilities to review safety.

Preparation of Pt/porous Gold Electrode for CO Oxidation (CO 가스 산화를 위한 백금/다공성 골드 전극의 개발)

  • Shin, So-Hyang;Kim, He-Ro;Oh, Cheon-Seok;Ko, Jae-Wook;Kim, Young-Hun
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.4
    • /
    • pp.27-32
    • /
    • 2011
  • Management of gas safety is becoming important with increasing use of gas facilities. U-safety system is being promoted as part of national management of gas, and thus real-time and in-situ gas sensor should be developed. Detection method for When the gas sensor is installed in gas conduit, explosion may be likely, because hydrocarbon gases is usually used the difference of thermal resistance between reference and working electrode. Therefore, it is required to detect the hydrocarbons, such as $CH_4$ and CO, at room temperature via electrochemically catalytic reaction. In this study, Pt nanoparticle was doped on the porous gold powder by electrolytic plating method, and then it was used as catalytic electrode for CO oxidation. For Pt/PAu electrode, approximately 21% of CO conversion was obtained. It is noted that Pt/PAu electrode could be used to react the oxidation of hydrocarbon gases at room temperature via applying of external voltage.