• Title/Summary/Keyword: 수리학적부하

Search Result 103, Processing Time 0.029 seconds

Effect of Hydraulic Loading on Biofilm Characteristics in an Inverse Fluidized Bed Biofilm Reactor (역 유동층 생물막 반응기에서 수리학적 부하가 생물막 성상에 미치는 영향)

  • 김동석;최윤찬
    • Journal of Environmental Science International
    • /
    • v.4 no.3
    • /
    • pp.221-228
    • /
    • 1995
  • Stability of reactor and effect on biofilm characteristics were investigated by varying the hydraulic residence time in an inverse fluidized bed biofilm reactor(IFBBR). The SCOD removal efficiency was maintained above 90 % in the HRT range of 12hr to 2hr, but the TCOD removal efficiency was dropped down to 50% because of biomass detachment from overgrown bioparticles. The reactor was stably operated up to the conditions of HRT of 2hr and F/M ratio of 4.5kgCOD/$m^3$/day, but above the range there was an abrupt increase of filamentous microorganisms. The optimum biofilm thickness and the biofilm dry density in this experiment were shown as $200\mu\textrm{m}$ and $0.08 g/cm^3$, respectively. The substrate removal rate of this system was found as 1st order because the biofilm was maintained slightly thin by the increased hydraulic loading rate.

  • PDF

A Study on Organics Removal and Methane Production during the Anaerobic Digestion of High-Strength Swine Wastes Using UASB Process (UASB 공정에 의한 고농도 축산폐수 처리시 유기물 제거와 메탄생성에 관한 연구)

  • Won, Chul-Hee;Kim, Seung-Ho;Park, Eun-Young;Rim, Jay-Myoung
    • Journal of Industrial Technology
    • /
    • v.22 no.B
    • /
    • pp.109-115
    • /
    • 2002
  • This research was performed to investigate the COD removal efficiency and methane production in slurry-typed swine wastes using UASB(upflow anaerobic sludge blanket)reactor. The USAB reactor was operated from 0.8 through 3.3days of HRT in a range of 3 to 15 kg $TCOD/m^3/day$ of volumetric organic loading rate. The removal rate of TCOD was increased with the increase of the HRT. The removal rate of TCOD at an HRT over 2days, became greater than 68% with the methane contents being from 70 to 80%. Methane production rates were increased from 0.27 to $0.36m^3\;CH_4/kg$ CODrem. as HRTs were increased from 0.8 to 3.3days.

  • PDF

A Predict Outflow and Water Quality of Yongbong-Chun Drainage District by using SWMM (SWMM을 이용한 용봉천 배수구역의 유출 및 수질모의)

  • Park Sung Chun;Oh Chang Ryol;Lee Youn Gil;Jung Chun Lee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1333-1337
    • /
    • 2005
  • 본 연구는 강우로 인한 도시 배수구역에서의 유출량 및 수질을 예측하기 위하여 영산강 유역의 도시하천이며 합류식 배수계통을 갖는 용봉천을 대상으로 SWMM 모형을 적용하였다. SWMM 모형의 매개변수 최적화 및 검증자료로 사용하기 위하여 강우시 2회에 걸쳐 조사하였으며, 매회 시료 채취 주기는 강우유출이 발생하기 전부터 시작하여 첨두유출량이 발생때까지 $1\~2$시간 간격으로 채취한 후 강우 종료 후 유출량 변화가 없을 때까지 $9\~12$단계로 세분하여 유출량과 pH, DO, BOD, COD, SS, T-N, T-P의 농도를 측정하였다. 모형의 입력자료는 국립지리원의 지형도, 환경부의 환경지리정보, 농업과학기술원의 정밀토양도 등을 기초로 각 배수구역의 소유역을 분할하여 물리학적$\cdot$수리학적 매개변수에 해당하는 입력자료를 산출하였으며 그림1과 같다. 모형의 보정자료는 2004년 6월 17일에 실측한 자료를 이용하여 침투능 계수 및 축적계수와 지수, 쓸림계수를 보정하였고, 검증자료로는 2004년 7월 7일에 실측한 자료를 이용하여 검증자료로 사용하였다. SWMM 모델을 적용해서 강우유출에 의한 hydrograph와 pollutograph를 도출하여 부하량을 산정 하였다.

  • PDF

Flood Estimation Considering Uncertainty (불확실성을 고려한 홍수량 추정)

  • Seo, Young-Min;Kim, Sung-Bum;Jang, Kwang-Jin;Jee, Hong-Kee;Lee, Soon-Tak
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1900-1904
    • /
    • 2007
  • 지금까지 수공구조물의 설계와 기존 시설의 안전도를 평가시 수문, 수리 및 경제학적 함수들에서 발생하는 불확실성을 설명하기 위하여 안전율 또는 여유고를 증가시키거나 이들 정보의 양과 질을 증가시켜 데이터베이스를 확장하고 측정오차를 최소화시키며, 전통적인 통계해석을 적용하였다. 공공의 안전을 확보하기 위하여 설계과정에 안전율 또는 여유고가 도입되었으나 이것은 단순히 보다 높은 재현기간의 적용을 의미하며, 수문현상이 가지는 추계학적 특성보다 확정론적인 근거로부터 안전설계 개념이 개발되었다. 수자원 계획시 고려되는 부하와 저항은 확정론적인 고정치가 아니라 시간에 따라 변하고 동적이며, 무작위적이므로 확률 변수로서 고려되어야 한다. 이에 따라 최근 수자원 계획과정에서 불확실성 해석에 의한 위험도 분석 개념이 도입되고 있으며, 특히 이상기후 및 집중호우의 빈발, 급격한 도시화로 인한 유출양상의 변화 등으로 급증하고 있는 훙수피해를 감안할 때 설계빈도의 상향조정과 같은 확정론적인 방법보다는 매개변수 또는 함수의 불확실성을 고려한 위험도 해석의 필요성이 더욱 증대되고 있는 실정이다. 따라서 본 논문에서는 수자원 계획시 입력자료 및 매개변수의 불확실성과 불확실성의 분리를 고려한 홍수량의 산정 및 각 매개변수의 영향을 평가하여 홍수위험도 해석에 있어서 모델 매개변수의 영향 규명과 처리방안을 제시하고자 한다.

  • PDF

Feasibility Study of Applying EMMC Process to Recirculation Water Treatment System in High Density Seawater Aquaculture Farm through Laboratory Scale Reactor Operation (실험실규모 반응조 운전을 통한 고밀도 해산어 양식장 순환수 처리공정으로서 EMMC공정의 적용 가능성 연구)

  • Jeong Byung Gon;Kim Byung Hyo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.7 no.3
    • /
    • pp.116-121
    • /
    • 2004
  • Treatability tests were conducted to study the feasibility of EMMC process as a recycling-water treatment system in high density seawater aquaculture farm. To study the effect of organic and ammonia nitrogen loading rate on system performance, hydraulic retention time was reduced gradually from 12hr to 10min. The conclusions are can be summarized as follows. When the system HRT was reduced from 12hr to 2hr gradually, there was little noticeable change(reduction) in ammonia nitrogen removal efficiencies. However, removal efficiencies were decreased dramatically when the system was operated under the HRT of less than 2hr. In case of organics(COD), there was no dramatic change in removal efficiencies depending on HRT reduction. COD removal efficiencies were maintained successfully higher than 9% when the system was operated at tile HRT of 10 min. System performances depending on media packing ratio in the reactors were also evaluated. There were little differences in each reactor performances depending on media packing ratio in reactor when the reactors were operated under the HRT of longer than 1hr. However, differences in reactor performances were considerably evident when the reactors were operated under the HRT of shorter than 1hr. When comparing reactor performance among 25%, 50%,7 5% packed reactor, it can be judged that media packing ratio more than 50% plays no significant role in increasing reactor performance. For this reason, packing the media less than 50% is more reasonable way in view of economic. Such a tendency shown in COD removal efficiencies well agreed with the variation of ammonia-nitrogen removal efficiencies according to the media packing ratio in reactors at each HRT. Difference in effluent ammonia-nitrogen concentration between 50% media packing reactor and 75% media packing reactor was negligible. When comparing with the results of 25% packing reactor, difference was not so great.

  • PDF

A Study on Treatment Characteristics and Design of Ultra High Rate Method (Ultra High Rate(UHR) 법의 처리특성 및 설계에 관한 연구)

  • Lee, Jeoung-Su
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.12
    • /
    • pp.2239-2245
    • /
    • 2000
  • For the treatment of wastewater being discharged in large quantities as in these modern times, qualitative and quantitative concepts should be introduced in consideration of the recycling. In view of a qualitative concept, high rate aeration process is known as the most effective process up to now. However, Lee suggested UHR process showing the superiority over high rate process in treatment rate and quantity. Therefore, this study was performed to investigate the basic sphere of design and treatment quality, such as applicable $BOD_5$-loading and influent wastewater concentration of UHR process, based on Lee's suggestions1). Consequently, this process showed applicable $BOD_5$-loading of $2.2{\sim}7.0kg-BOD_5/kg-MLSS{\cdot}day$, exceeding three times or more of high rate process with maximum applicable loading of $2.25kg-BOD_5/kg-MLSS{\cdot}day$. Meanwhile, with the range of influent wastewater concentration from 200 to 450 mg/L. it showed the treatment rate from 94.7 to 97.3%, it indicated very good condition. In view of quantitative concept of treatment, UHR process is considered an epoch-making treatment process being superior to existing ones.

  • PDF

The Waveform and Spectrum analysis of Tursiops truncatus (Bottlenose Dolphin) Sonar Signals on the Show at the Aquarium (쇼 학습시 병코돌고래 명음의 주파수 스펙트럼 분석)

  • 윤분도;신형일;이장욱;황두진;박태건
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.2
    • /
    • pp.117-125
    • /
    • 2000
  • The waveform and spectrum analysis of Tursiops truncatus(bottlenose dolphin) sonar signals were carried out on the basis of data collected during the dolphin show at the aquarium of Cheju Pacificland from October 1998 to February 1999. When greeting to audience, the pulse width, peak frequency and spectrum level from the five dolphins'sonar signals were 3.0ms, 4.54kHz and 125.6dB, respectively. At the time of warm-up just before the show, their figures were 5.0㎳, 5.24kHz and 127.0dB, respectively. During the performance of dolphins, with singing, peak frequency ranged 3.28∼5.78kHz and spectrum level ranged 137.0∼142.0dB. With playing ring, pulse width, peak frequency and spectrum level were 7.0㎳, 2.54kHz and 135.9dB, and when playing the ball, the values were 9.0㎳, 2.78kHz and 135.2dB, respectively. The values determined from the five dolphins during jump-up out of water were : pulse width 2.0㎳, peak frequency 4.50kHz and spectrum level 126.8dB. When they responded to trainer's instructions, the values were 2.25㎳, 248kHz and 148.7dB, respectively, and greeting to audience, the peak frequency and spectrum level were 5.84kHz and 122.5dB. During swimming under water, peak frequency and spectrum level were determined to be 10.10kHz and 126.8dB. It was found that there exited close consistencies in pulse width, frequency distribution and spectrum level between whistle sounds and dolphin's sonar signals. Accordingly, the dolphins can be easily trained by using whistle sound based on the results obtained from the waveform and spectrum of the dolphin's sonar signals.

  • PDF

The Simulation for the Organization of Fishing Vessel Control System in Fishing Ground (어장에 있어서의 어선관제시스템 구축을 위한 모의실험)

  • 배문기;신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.3
    • /
    • pp.175-185
    • /
    • 2000
  • This paper described on a basic study to organize fishing vessel control system in order to control efficiently fishing vessel in Korean offshore. It was digitalized ARPA image on the fishing processing of a fleet of purse seiner in conducting fishing operation at Cheju offshore in Korea as a digital camera and then simulated by used VTMS. Futhermore, it was investigated on the application of FVTMS which can control efficiently fishing vessels in fishing ground. The results obtained were as follows ; (1) It was taken 16 minutes and 35 minutes to casting and hauling net in fishing processing respectively. The length of rope pulled by scout boat was 200m, tactical diameter in casting net was 340.8m, turning speed was 6kts as well. (2) The processing of casting and hauling net was moved to SW, NE as results of simulation when the current direction and speed set into NE, 2kts and SW, 2kts respectively. Such as these results suggest that can predict to control the fishing vessel previously with information of fishing ground, fishery and ship's maneuvering, etc. (3) The control range of VTMS radar used in simulation was about 16 miles. Although converting from a radar of the control vessel to another one, it was continuously acquired for the vector and the target data. The optimum control position could be determined by measuring and analyzing to distance and direction between the control vessel and the fleet of fishing vessel. (4) The FVTMS(fishing vessel traffic management services) model was suggested that fishing vessels received fishing conditions and safety navigation information can operate safely and efficiently.

  • PDF

Activity of Methanogens in the High Rate Anaerobic Digestion of Swine Wastewater Containing High Ammonia (고농도 암모니아를 함유한 돈사폐수의 고율혐기성 소화시 메탄균의 활성연구)

  • Oh, Sae-Eun;Lee, Chae-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.5
    • /
    • pp.981-987
    • /
    • 2000
  • Upflow anaerobic sludge blanket(UASB) reactor was operated for treating swine wastewater containing high ammonia nitrogen to assess their performance and toxicity of free ammonia concentration. In the reactor, chemical oxygen demand(COD) removed about 70% at $2.6kgCOD/m^3.day$ of organic loading rate(OLR) and 3 days of hydraulic retention time (HRT), while it was decreased when OLR and HRT was maintained $7kg\;COD/m^3.day$ and 2 days, respectively. Also UASB reactor was evaluated the activity of methane producing bacteria(MPB) according to change of free ammonia concentrations, MPB activity of applied sludge in the 500 and $1000mg-N/{\ell}$ of free ammonia concentration was inhibited by 4% and 40%, respectively. This clearly showed that free ammonia concentration less than $500mg-N/{\ell}$ showed no inhibition to MPB in anaerobic treatment of organics, UASB reactor was stabilized easily less than $1000mgVSS/{\ell}$ due to degradation of organic solids by the high activities of anaerobes.

  • PDF

Comparison of Pollutant Removal Efficiency in Road Sediment with Media Using Filter Separator (필터 분리기를 이용한 여재별 도로퇴적물의 오염물질 제거효율 비교)

  • Bang, Ki-Woong;Lee, Jun-Ho;Choi, Chang-Su;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.332-340
    • /
    • 2007
  • Storm runoff from road contains significant loads of particulate and dissolved solids, organic constituents and metal elements. Micro particle is important when considering pollution mitigation because pollutant metal and organics have similar behavior with particles. The objective of this research is to evaluate the hydrodynamic filter separator performance for road storm runoff treatment. A various types of media such as perlite, granular activated carbon, zeolite were used for column test packing media and filter separator, and to determine the removal efficiency with various surface loading rate. As the results of column test, the highest SS removal efficiency was using mixed media(granular activated carbon, zeolite and perlite), and granular activated carbon mixed with zeolite has higher heavy metal removal efficiency than perlite. In laboratory scale hydrodynamic filter separator study, the operation ranges of surface loading rates were from 192 to 1,469 $m^3/m^2/day$. The estimated overall removal efficiencies of hydrodynamic filter separator for typical storm runoff were SS 48.1%, BOD 31.9%, COD 32.6%, TN 15.5%, and TP 17.3%, respectively. For the case of heavy metals, overall removal efficiencies were Fe 26.0%, Cu 19.4%, Cr 25.7, Zn 16.6%, and Pb 15.0%, respectively. The most appropriate medium for hydrodynamic filter separator was perlite mixed with granular activated carbon to treatment of road storm runoff.