• Title/Summary/Keyword: 수로손실

Search Result 75, Processing Time 0.028 seconds

A Study on the Leakage Protection with Polypropylene Mat in Irrigation Canal (Polypropylene Mat에 의(依)한 용수로(用水路)의 누수방지(漏水防止)에 관(關)한 연구(硏究))

  • Kang, Sin-Up;Kang, Yea-Mook;Cho, Seung-Seup
    • Korean Journal of Agricultural Science
    • /
    • v.6 no.2
    • /
    • pp.166-184
    • /
    • 1979
  • In order to prevent the water loss in the irrigation canal constructed on the sandy gravel layer or on the other highly permeable ground layer, lining has been practiced. Many studies have been done so far on the lining method to prevent the water loss in the irrigation canal and recently studies on the lining with plastic film or polyethylene film were also reported. However, the plastic film or polyethylene film has low strength and is liable to break, and water loss from pin hole caused by contacting with sand or gravel is highly predicted. This study was then conducted to find proper lining and buring method in canal construction of polypropylene mat after coated with vinyl, as one way to overcome the shortcoming frequently observed when plastic or usual polyehtylene film were used. Eventhough rather longer periods of experiments are needed to attain reliable and accurate results on the variation of durability, the durability of asphalt coated area, or on the damage due to freeze after burial or exposure of polypropylene mat, the experiemental results obtained during one year of period are summarized as follows: 1. The curvature at the area between canal bottom and side slope had increased stability and saved consruction cost. The relationship among the variation of curvature, the reduction of polypropylene mat and the reduced amount of soil cutting at each side slope was presented in Fig. 7 through 9. 2. The depth of covering material to protect polypropylene mat was desired to be over 30cm, considering the water depth, side slope, canal cleaning practices, traffic, or back pressure of irrigation period. 3. In order to increase the canal stability and to prevent slope erosion, sandy soil was required, to be placed under ground, and coarse gravel should cover the surface area of canal. 4. The studies on the stability of side slope in the canal should consider the passive area on the bottom and the slope should be about 1 to 2, considering the slope stability, allowable velocity and tractive force. 5. When compared with earth lining, the lining with polypropylene mat coated with vinyl was responsible to save 28% and 37% of canal lining cost, when the soil carrying distances were 500 and 700m. respectively. 6. The water interception was almost completely attained when the polypropylene mat coated with vinyl was used for lining. But further studies were assumed to be necessary for the use of asphalt since the strength of polypropylene mat connected with asphalt will vary with duration.

  • PDF

A Study on Imposing Exact Solutions as Internal Boundary Conditions in Simulating Shallow-water Flows over a Step (계단을 지나는 천수 흐름의 모의에서 내부 경계조건으로서 정확해의 부여에 관한 연구)

  • Hwang, Seung-Yong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.479-492
    • /
    • 2014
  • In this study, was proposed a numerical scheme imposing exact solutions as the internal boundary conditions for the shallow-water flows over a discontinuous transverse structure such as a step. The HLLL approximate Riemann solver with the MUSCL was used for the test of the proposed scheme. Very good agreement was obtained between simulations and exact solutions for various problems of the shallow-water flows over a step. In addition, results by the numerical model showed good agreement with those of dam-break experiments over a step and stepped chute one. Developed model can simulate the shallow-water flows over discontinuous bottom such as a drop structure without additional rating curve or topography smoothing. Given the proper evaluations for the flow resistance by a step and the energy loss by the nappe flow in the future, could be simulated flooding and drying of the shallow-water flows over discontinuous topography such as a weir or the river road with retaining wall.

Cooperative Multipath Routing Protocol for Wireless Sensor Networks (무선 센서 네트워크를 위한 협력 다중경로 라우팅 프로토콜)

  • Jung, Kwansoo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.8 no.5
    • /
    • pp.419-428
    • /
    • 2015
  • Multipath routing technique is recognized as one of the effective approaches to improve the reliability of data forwarding. However, the traditional multipath routing focuses only on how many paths are needed to ensure a desired reliability. For this purpose, the protocols construct additional paths and thus cause significant energy consumption. These problems have motivated the study for the energy-efficient and reliable data forwarding. Thus, this paper proposes an energy-efficient cooperative multipath routing protocol with a small number of paths based on an inter path communication. The inter path communication (namely, cooperative multipath routing) in the proposed protocol helps to reinforce the multipath reliability and reduce the use of network resources. In addition, the proposed protocol provides a reliable end-to-end transmission time by using a transmission recovery method based on the local decision for the path or transmission failures.

Variation of Salt Concentration for the Intrust Sea Water in the Kyongin Navigation Channel (경인운하 수로에서 해수유입에 의한 염분농도의 변화)

  • Lee, Gil-Seong;O, Seong-Taek
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.2
    • /
    • pp.209-219
    • /
    • 1998
  • Sea water volume intruded from the lock gated was compted by a one-dimensional numerical model and the extent of diffusion of sea water was evaluated for that. The volume of intruded sea water, in the exchange processes of salt and fresh waters, was computed by the conceptual model considering the tidal level, volume of chamber, volume of canal, and operation period only, It was divided into some cases according to whether ships enter or leave the canal and whether the level of tide is lower or higher than that of water level in canal. The model, developed in this work, assumed that intruded sea water is well mixed in the canal; and complete is the exchange of waters between sea and canal. The simulation case was divided into two categories according to whether the water was added from the Han River or not.

  • PDF

A Study on a Perforated Breakwater (유공방파제에 대한 연구)

  • Lee, Yong-Gyu;Pyeon, Jong-Geun;An, Su-Han
    • Water for future
    • /
    • v.19 no.2
    • /
    • pp.131-138
    • /
    • 1986
  • Both hydraulic and dynamic characteristics of a single perforated wall are studied theoretically and experimentally. Theoretically, the effect of evanescent modes on wave force acting on a single perated wall is studied by use of the Horiguchi theory. The wave force on the perforated wall is presented to be insensitive to evanescent modes. According to experimental study, The larger perforation ratio(${\gamma}$) grows, the weaker the wave force on the wall becomes sensitively. And in the small value of l/D (ratio of wall thickness(l) to hole diameter(D)) where the holes on the wall are regarded as orifice, the wave force on the wall is insensitive to the variation of l/D. Energy loss coefficient f is estimated at 1.0 in this small value of l/D by use of Horiguchi theory. But in the large value of l/D where the holes are regarded as pipe, the wave force on the wall is relatively sensitive to the variation of l/D and f is estimated at 1.5 by use of Horiguchi theory.

  • PDF

Power Generation and Control System Using Differential Pressure of District Heating Pipeline in a Substation (지역난방 사용자기계실 내 열수송관 차압을 이용한 발전 및 제어 기술)

  • Kim, Kyung Min;Park, Sung Yong;Oh, Mun Sei
    • Journal of Energy Engineering
    • /
    • v.26 no.3
    • /
    • pp.90-96
    • /
    • 2017
  • When the hot water is supplied through the district heating (DH) pipeline, a pressure differential control valve (PDCV) protects the DH user equipment from the high pressure DH water and helps to supply DH water to long distance. It also controls the temperature and adjust the pressure in the main district heating pipeline. However, cavitation occurs in PDCV due to the use of high pressure DH water. It causes frequent failures and many problems. It also causes energy loss and complaints to both operators and users. In order to solve these problems, we will introduce the energy saving technology to replace the primary side PDCV with hydraulic turbine, convert the differential pressure into electricity, and utilize electricity as the power of the secondary side pump.

Data Analysis and Health Index for Health Monitoring of Seohae Bridge (서해대교 건전성 모니터링을 위한 데이터 분석 및 건전성지수)

  • Kim, Hyunsu;Kim, Yuhee;Park, Jongchil;Shin, Soobong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.387-395
    • /
    • 2013
  • It is important to collect reliable measured data for proper bridge health monitoring. However, in reality incomplete and unreliable data may be acquired due to sensor problems and environmental effects. In case of sensor malfunction, parts of measured data are missing and thus health monitoring cannot be carried out reliably. Due to environmental effects such as temperature variation, dynamic characteristics of natural frequencies may change as if the structure is damaged. The paper proposes a systematic procedure of data processing and data analysis for reliable structural health monitoring. Also, it applies the Mahalanobis distance as a health index computed statistically using revised data. The proposed procedure has been examined using numerically simulated data from a truss structure and then applied to a set of field data measured from Seohae cable-stayed bridge.

Experimental Study on Seepage Losses in Earth Channel (흙 수로에 대한 삼수손실량 추정에 관한 실험적 연구)

  • 정하우;유한열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.15 no.1
    • /
    • pp.2853-2877
    • /
    • 1973
  • Models of cross-sections and channels were made in order to measure seepage losses. Cross-sections were made of sand, sandy clay loam and loam, their thicknesses being 30cm and 40cm, respectively. Flow depths kept in the cross-sections were 4cm, 6cm, 8cm and 10cm. Straight and curved channel models were provided so as to measure seepage losses, when constant water depths maintained at the heads of the channels were 7.3cm and 5.7cm, respectively. The results obtained in this experiment are presented as follows: 1) A cumulative seepage loss per unit length at a point in the channel varies in accordance with time and flow depth. The general equation of cumulative seepage loss may be as follows(Ref. to Table V.25): $$q_{cum}=\int_{o}^aq(a)dt+\int_a^bq(b)dt+\int_b^tq(c)dt$$ 2) In case that the variation of water depth through the channel is slight, the total seepage loss may be computed by applying the following general equation: $$\={q}_{cum}{\cdot}x=\int_o^tq_{cum}\frac{{\partial}x}{{\partial}t}dt$$ 3) Because seepage loss varies considerably according to water depth in case that the variation of flow depth through the channel is great, seepage loss should be computed by taking account of the change of flow depth. 4) The relation between time and traveling distance of water flow may be presented as the following general equation(Ref. to Table V.29): $$x=pt^r$$ 5) The ratios of the seepage losses of the straight channel to the curved channel are 1:1.03 for a flow depth of 7.3cm and 1:1.068 for that of 5.7cm. 6) The ratios of the seepage losses occurring through the bottom to those through the inclined plane in the channel cross-section are 1:2.24 for a water depth of 8cm and 1:2.47 for a depth of 10cm in case that soil-layer is 30cm in thickness. Similarly, those ratios are 1:2.62 and 1:2.93 in case of a soil-layer thickness of 40cm(Ref. to Table V.5).

  • PDF

SDGs approach towards Building Resilience to Disaster and Climate Change (재해에 대한 리질리넌스 확보를 위한 지속가능개발목표의 이행)

  • Hong, Ilpyo;Park, Jihyeon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.77-77
    • /
    • 2016
  • 최근 기후변화로 인한 수문기상학적인 극한 사상들은 점점 대형화되고 있고, 그 발생빈도 또한 잦아지고 있다. 인구의 증가와 급격한 도시화, 자산 가치의 증가 등으로 물과 관련된 재해로 인한 피해는 점점 더 규모가 커지고 있다. 홍수와 가뭄, 허리케인, 쓰나미와 같이 물과 관련된 재해는 그 영향을 받는 사람들의 수로 본다면 지구상의 재해 중 90%를 차지하고 있을 만큼 그 규모가 크다 할 수 있으며, 전세계적으로 물관련 재해로 인한 재산상의 피해를 약 1,000억 달러 규모로 추산하고 있는데, 2030년에는 그 현재의 두 배가 될 것으로 예측하고 있다. 이와 같은 재해로 인한 피해는 개도국이나 최빈국뿐만 아니라 관련 인프라가 잘 구축되어 있는 선진국 또한 예외는 아니다. 2015년 9월 UN 세계지속가능 정상 회의에서 각국의 수반들 또한 17개의 "지속가능개발목표(Sustainable Development Goals; SDGs)"를 채택함으로서 post-2015 아젠다가 세계를 지속가능하고 균형 있게 바꾸어 나가기 위해서 취해야 하는 가장 시급하고 필요한 과감한 혁신적인 조치임을 인식하였다. 재해경감과 지속가능개발은 2005년 채택된 "효고프레임웍(Hyogo Framework for Action) 2005-2015"에서 도 중요하게 다루어 졌다. 2015년 3월 제3차 세계재해경감대회에서 채택된 "센다이 프레임웍(Sendai Framework for Disaster Risk Reduction) 2015-2030"은 Post-2015 개발의제의 첫 번째 합의 결의안이라 할 수 있으며, 인명피해의 실질적인 감소와 재해에 의한 영향으로 피해 보는 사람들의 수를 줄이고, 경제적 손실과 대형 인프라 피해의 경감을 주요 타겟으로 하고 있다. 이와 같은 리질리언스의 중요성은 SDGs의 Goal 11인 "안전하고 지속가능한 도시와 정주지 조성(Make cities and human settlements inclusive, safe, resilient and sustainable)"에서 강조되고 있을 뿐만 아니라 다양한 골에서 재해로 부터의 리질리언스 확보에 대한 필요성을 강조하고 있다. 재해 위험을 경감시키기 위해서 국제적으로, 지역적으로 또는 국경을 넘어서는 협력 관계의 구축이 중앙정부나 지방정부를 비롯한 국가적으로 절대적으로 필요한 노력이라 할 수 있다. 특히나, Post-2015 개발 아젠다에 대한 기후변화와 재해경감을 위한 금융지원을 포함한 최빈국, 개도국, 군소 도서국가들과 중견국 선진국들의 양자간이나 다자간 협력 채널을 통한 역량 강화가 필요하다.

  • PDF

Development and Application of Reliability Index based on Hydraulic Uniformity in Water Distribution Networks (상수관망의 수리학적 균등성을 이용한 신뢰도 지표의 개발 및 적용)

  • Jeong, Gimoon;Kang, Doosun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.6-6
    • /
    • 2019
  • 상수관망시스템은 공급원으로부터 수요처까지의 용수공급을 위해 구축된 관수로 기반의 사회기반시설물로서, 주로 생활 및 산업 용수를 공급하므로 대규모 사회 경제적 피해를 방지하기 위해서는 안정적인 용수공급 능력이 요구된다. 네트워크의 다양한 특성에 의해 표현되는 상수관망시스템의 신뢰도(reliability)는 크게 시스템 내 구성요소의 안정성(mechanical reliability)과 용수공급의 기능적 안정성(hydraulic reliability)으로 구분할 수 있다. 특히, 시스템의 용수공급 안정성에 주목한 수리학적 신뢰도 연구는 많은 연구자들에 의해 지속적으로 수행된 바 있으며, 다양한 평가방법 및 지표들이 제시되어 활용 중에 있다. 기존의 수리학적 신뢰도 지표들은 주로 수요절점(demand node)에서의 공급가능 수량 및 수압을 바탕으로 산정되었다. 그러나, 절점(node)에서의 공급 상태는 결과에 해당하며, 원인 분석을 위해서는 관로(pipe)의 배치 및 규격을 분석해야 하는 번거로움이 존재한다. 이러한 단점을 보완하기 위해, 본 연구에서는 직접 관로(pipe)의 공급 특성을 분석하여 네트워크의 신뢰도를 평가함으로써, 신뢰도 저하의 원인 분석 및 시스템 개선에 효율적으로 활용할 수 있는 신뢰도 지표를 산정하고자 하였다. 본 연구에서는 상수관로 내 수리학적 기울기가 전반적으로 균등할수록 설계 비용대비 공급 신뢰도, 즉 용수공급 효율이 개선되는 특징을 바탕으로, 네트워크 내 총 에너지 손실로부터 각 관로의 길이, 유량 등의 특성을 고려한 등가 수리경사(Equivalent hydraulic gradient)를 유도하여 모든 관로의 적정 수리경사로 제안하였다. 따라서 각 관로의 실제 수리경사를 대상으로 관로별 수리학적 균등성 지수(pipe hydraulic uniformity index)를 산정하였으며, 더 나아가 전체 시스템의 균등성 지수(system hydraulic uniformity index)를 산정하였다. 제안된 신뢰도 지표는 가상의 네트워크에서 지역 내 용수 사용량이 증가하는 등 용수공급 안정성을 저해하는 몇 가지 시나리오를 바탕으로 검증하였으며, 또한 기존 지표들의 신뢰도 평가 결과와 비교, 분석하였다. 본 연구는 향후 네트워크 최적 설계의 목적함수로 활용하거나, 네트워크의 보강계획 수립에 기여할 것으로 기대된다.

  • PDF