베이즈 분류기를 이용한 수냉식 냉동기의 고장 진단 방법에 관한 실험적 연구 (An Experimental Study on Fault Detection and Diagnosis Method for a Water Chiller Using Bayes Classifier)

  • 이흥주;장영수;강병하
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.36-41
    • /
    • 2008
  • Fault detection and diagnosis(FDD) system is beneficial in equipment management by providing the operator with tools which can help find out a failure of the system. An experimental study has been performed on fault detection and diagnosis method for a water chiller. Bayes classifier, which is one of classical pattern classifiers, is adopted in deciding whether fault occurred or not. FDD algorithm can detect refrigerant leak failure, when 20% amount of charged refrigerant for normal operation leaks from the water chiller. The refrigerant leak failure caused COP reduction by 6.7% compared with normal operation performance. When two kinds of faults, such as a decrease in the mass flow rate of cooling water and temperature sensor fault of cooling water inlet, are detected, COP is a little decreased by these faults.

  • PDF

베이즈 분류기를 이용한 수냉식 냉동기의 고장 진단 방법에 관한 실험적 연구 (An Experimental Study on Fault Detection and Diagnosis Method for a Water Chiller Using Bayes Classifier)

  • 이흥주;장영수;강병하
    • 설비공학논문집
    • /
    • 제20권7호
    • /
    • pp.508-516
    • /
    • 2008
  • Fault detection and diagnosis(FDD) system is beneficial in equipment management by providing the operator with tools which can help find out a failure of the system. An experimental study has been performed on fault detection and diagnosis method for a water chiller. Bayes classifier, which is one of classical pattern classifiers, is adopted in deciding whether fault occurred or not. Failure modes in this study include refrigerant leakage, decrease in mass flow rate of the chilled water and cooling water, and sensor error of the cooling water inlet temperature. It is possible to detect and diagnose faults in this study by adopting FDD algorithm using only four parameters(compressor outlet temperature, chilled water inlet temperature, cooling water outlet temperature and compressor power consumption). Refrigerant leakage failure is detected at 20% of refrigerant leakage. When mass flow rate of the chilled and cooling water decrease more than 8% or 12%, FDD algorithm can detect the faults. The deviation of temperature sensor over $0.6^{\circ}C$ can be detected as fault.

냉각성능 분석오류 (Mistakes of Cooling Tower Performance Analysis)

  • 권오익
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권3호
    • /
    • pp.397-404
    • /
    • 2004
  • 냉각탑이란 석유화학플랜트, 철강플랜트 등과 같은 생산 공정이나 냉동기를 비롯한 각종 기계장치에서 발생된 열을 수냉식 열 교환장치에서 물로 직접 냉각시킬 때 공정유체의 열을 전달받아 데워진 물을 대기의 공기와 직접 접촉시켜 물의 증발 잠열을 이용하여 원하는 온도로 냉각시켜 주는 기계장치이다.(중략)

가스냉난방기용 4성분계 흡수용액의 수증기 흡수특성에 관한 실험적 연구 (A experimental study of water vapor absorption characteristics using four components solution for gas fired absorption chiller)

  • 이용원;오영삼;박달령;백영순
    • 한국가스학회지
    • /
    • 제2권4호
    • /
    • pp.47-52
    • /
    • 1998
  • 수냉식 흡수식 냉동기에 주로 사용되고 있는 LiBr/water 흡수용액을 대체할 수 있는 신흡수 용액으로 제안된 흡수용액중 4성분계 흡수용액($LiBr+LiNO_3+LiC1+H_2O$)의 수증기 흡수성능을 수직관 흡수기를 사용하여 시험하였다. 시험변수로는 입구농도, 입구온도, 냉각수 입구온도, 용액유량을 변경하였다. 수증기 흡수특성 시험 결과 4성분계 용액이 LiBr/water용액보다 $2\%$ 높은 농도에서 대둥한 흡수력을 가짐을 알 수 있었다. 그러나 4성분계 흡수용액이 LiBr/water용액보다 $3\%$정도 용해도가 높으므로 실제 흡수식 냉동기에 적용시 LiBr용액보다 우수한 흡수능력을 가질 수 있어 소형, 공냉형 흡수식 냉동기에 적용이 가능하다.