• Title/Summary/Keyword: 수격 현상

Search Result 71, Processing Time 0.028 seconds

Simulation of Water Hammer Mitigation at Seobyun Pumping Station (서변 가압장에서 수격현상 완화에 대한 연구)

  • Kim, Sang Hyun;Park, Nam Sik;Jung, Bong Seog;Lee, Dong Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.2
    • /
    • pp.95-104
    • /
    • 1999
  • A simulation of water hammer, introduced by abruptly varied motion of a pumping machine, was performed at a one of typical pumping station in Korea. Impact of hydraulic structure such as check valve, pressure relief valve and air valve in mitigating water hammer effect was estimated gradually. Method of characteristic was employed for the effective calculation of discharge and head. The relationship between various hydraulic structures and flow was properly integrated on the base of the method of characteristic. The methodology in this approach can provide significant contribution in decision making procedure for the design of hydraulic structure at a typical pumping station in Korea.

  • PDF

Characteristics of Forced Vibration of Valve-pipe Systems with a Crack (크랙을 가진 밸브 배관계의 강제진동 특성)

  • Son, In-Soo;Kim, Chang-Ho;Cho, Jeong-Rae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.11
    • /
    • pp.1049-1056
    • /
    • 2012
  • The forced vibration response characteristics of a cracked pipe conveying fluid with a concentrated mass are investigated in this paper. Based on the Euler-Bernoulli beam theory, the equation of motion is derived by using Hamilton's principle. The effects of concentrated mass and fluid velocity on the forced vibration characteristics of a cracked pipe conveying fluid are studied. The deflection response is the mid-span deflection of a cracked pipe conveying fluid. As fluid velocity and crack depth are increased, the resonance frequency of the system is decreased. This study will contribute to the decision of optimum fluid velocity and crack detection for the valve-pipe systems.

Numerical Analysis of the Dynamical Characteristics of Fluid Flow Inside a Pipe with an Accumulator (축압기가 부착된 관로의 동특성 수치해석)

  • 서용권
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.5
    • /
    • pp.388-397
    • /
    • 2001
  • This paper addresses characteristics of compressible flow dynamics inside a pipe with an accumulator and an inlet orifice. It also presents a simple but stable numerical method associated with the accumulator-orifice calculation. In particular, a focus is given to developing a method of finding an optimum design of the accumulator-orifice system (i.e., the accumulator size and the throttle resistance) that gives the most effective dissipation of the water-hammering problem. It is found that there exists indeed an optimum set of parameter values for the most effective dissipation of the wave energy.

  • PDF

Design and Performance Prediction of an Air Chamber for Reduction of Water Hammering (수충격 완화용 공기 챔버의 설계 및 성능 예측에 관한 연구)

  • Kang, S.H.;Ryu, H.S.;Park, M.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.1
    • /
    • pp.57-64
    • /
    • 1992
  • A computer program was developed for the prediction of transient flow in a water supply system. where an air chamber is installed to reduce the water hammering. The governing equations based on a characteristic method are solved using a finite difference method. A design process of an air chamber is shown in the present paper considering the effects of the initial air volume and the discharge coefficients of the orifice on the total volume and over-all performance of the chamber.

  • PDF

A Study on the Nonlinear Behavior of Check Valve System (체크밸브의 비선형거동에 관한 연구)

  • 박철희;홍성철;박창배
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.35-41
    • /
    • 1993
  • 산업사회가 발전함에 따라 거대한 플랜트(plant)를 포함하여, 원자력 발전소 와 로켓트 등과 같이 구조적 안전성과 정확한 성능의 확보가 극히 중요시되 는 설비들이 많이 등장하고 있다. 이들 설비를 구성하고 있는 파이프계 (piping system)는 강성 또는 연성재료 및 각종 valve등으로 구성되어 있기 때문에, 고온 고압 고속의 유체가 파이프 내부를 흐를 때 일으키는 진동현상 및 플랜트의 과도운전 상황에서의 일어나는 수격현상(water hammer 또는 steam hammer)과 이로 기인한 제반 진동문제는 안전성확보 측면에서 많은 관심이 고조되고 있다. 이와 관련되어 유체유발진동에 관한 많은 연구들이 수행되었으며, 파이프계에 장착된 밸브에 대한 연구는 Weaver등에 의하여 실험적, 이론적으로 수행되었다. 그들은 유동방정식에서 비정상 베르누이 방 정식을 사용하여 내부유동방정식을 간략하게 유도하였으나, jet flow에 의한 유체의 운동량변화를 고려하지 않고 해석되어 그 결과에 의문이 제기된다. 그러므로 본 연구에서는 체크밸브(check valve)가 부착된 파이프계에서 일어 나는 유체유발진동 및 안정성에 관한 이론적 연구를 수행하여, 파이프계의 설계에 필요한 파라미터의 영향을 파악하고자 한다. 원자력 발전소와 같이 구조적 안정성이 요구되는 플랜트를 국내 기술로 설계 시공하려는 국내 실 정에서 이로 인한 파이프계에 발생할 수 있는 유체유발진동과 안정성을 예 측할 수 있는 해석이론은 파이프계의 설계 및 운전조건의 선정에 있어서 그 의의가 크다고 할 수 있겠다.

  • PDF

Study on a Multi-pipe Water Hammer Phenomenon by using CFD of Rapid Valve Closing (전산유체해석(CFD)을 이용한 밸브의 급폐쇄에 따른 다중 배관 수격 현상에 관한 연구)

  • Park, No-Suk;Kim, Seong-Su;Kang, Moon-Sun;Choi, Jong-Woong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.4
    • /
    • pp.479-487
    • /
    • 2013
  • This study was to investigate characteristics for the pressure wave propagation and the maximum pressure near a rapid closure valve which was installed the end of multi piping network. The multi piping network consists of one inlet and three outlet with straight pipes. The diameter of the pipes including the valve was 100 mm, 80 mm, 80 mm respectively. The valve was rapidly closed with the instantaneous time which was 0.023s in the level for the water hammer. For the simulation, the influence of the pipe thickness and deformation due to pressure-wave-propagation was not considered. CFD was conducted under the following condition : the initial pressure was 1bar in the inlet and the mass flow rate was 7.83 kg/s in the outlet(the velocity in the pipe with 100 mm diameter was 1 m/s). As the valve have conditions that were status with and without fluid flow in the pipe after valve closing, the maximum pressure change and the frequency analysis were examined. As the results, the case that was status with fluid flow appeared the higher maximum pressure than another's, the maximum frequency band was about 10 ~ 11 Hz.

The Effect of Compliance Structures Near the Mechanical Heart Valve on Valve Surface Erosion (기계식 인공 판막 주위의 유연성 구조가 표면 괴식에 미치는 영향)

  • Lee, Hwan-Sung;Hwang, Sung-Won;Sun, Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.309-315
    • /
    • 2002
  • Since the discovery, in the 1980s, of erosion-pit-induced fractures in implanted mechanical heart valves. cavitation on the surface of mechanical heart valves has been widely studied as a possible cause of pitting. Several factors, including peak dp/dt of the ventricular pressure. maximum closing velocity of the leaflet, and squeeze flow. have been studied as indices of the cavitation threshold. In the present study. cavitation erosion on the surface of a mechanical valve was examined by focusing on squeeze flow and the water hammer phenomenon during the closing period of the valve. In this study, we measures pressure wave forms near a valve and closing velocities of a disk, which were placed in a holder with and without compliance. In case of all holders, pressure drop of below vapor pressure expect at near the surface disk. It was also found that the closing velocity of the disk increased and that cavitation erosion was enhanced too. These results suggest that disk closing velocity during the closing phase has signifiant effects on pitting erosion.

A Study of Interpolation Methods for the Water Hammer Analysis using the Method of Characteristics (특성선 방법을 이용한 관망 수격현상 해석의 보간방법연구)

  • Jung, Bong Seog;Kim, Chu In;Kim, Sang Hyun;Park, Nam Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.363-373
    • /
    • 2000
  • It is necessary to employ the interpolation technique to resolve problems, which are associated with the characteristic locus in time-distance space, in the unsteady analysis of pipe flow. Various interpolation methods such as linear timeline interpolation, linear spaceline interpolation, wave speed adjustment, cubic spaceline interpolation and cubic timeline interpolation have been suggested and tested to investigate the interpolation error. Performance of various interpolation techniques was evaluated both a single pipeline and a complex one. The range of error was calculated as the courant number varied between 0 and 1 in a single pipeline. Reorganization of computational element and proper selection of interpolation method are found to be prerequisites for the effective computation of unsteady analysis.

  • PDF

A Study on the Steam Hammering Characteristics by Sudden Closure of Main Stop Valve in the Main Steam Piping System of a Power Plant (화력발전소 주증기배관에서 밸브 차단에 따른 수증기 충격 특성에 관한 연구)

  • Ha, Ji-Soo;Lee, Boo-Youn
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.2
    • /
    • pp.70-77
    • /
    • 2013
  • The present study has been carried out to analyze the effect of steam hammering on the steam piping system including the final superheater, the high pressure turbine, check valve and the first reheater by sudden stoping of main stop valve in a power plant. For the present steam hammering analysis, the well known Flowmaster software has been used to model the steam piping system and the time dependent characteristics of pressure and steam mass flow rate has been conducted. Using the result of the unsteady pressure and steam mass flow rate, the forces acting on the elbows in the piping system has been derived. From the present analysis, it has been elucidated that the elbow just before the main stop valve and the elbow near the connection pipe between bypass pipe and check valve had the largest force among the elbows in the steam piping system. The structural safety diagnostics study on the elbow and the supporting structures of the steam piping system of a power plant will be conducted in the future by the present results of the forces acting on the elbow.

Water-hammer in the Pump Pipeline System with and without an Air-Chamber (에어챔버 설치에 따른 펌프관로계의 수격현상)

  • Lee, Sun-Kon;Yang, Cheol-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • When the pumps stopped in the operation by the power failure, the hydraulic transients take place in the sudden change of a velocity of pipe line. Each and every water hammer problem shows the critical stage to be greatly affected the facts of safety and reliability in case of power failure. The field tests of the water hammer executed at Cheong-Yang booster pump station having an air chamber. The effects were studied by both the practical experiments and the CFD(Computational Fluid Dynamics : Surge 2008). The result states that the system with water hammering protection equipment was much safer when power failure happens. The following data by a computational fluid dynamic analysis are to be shown below, securing the system stability and integrity. (1) With water hammering protection equipment. (1) Change of pressure : Up to $15.5\;kg/cm^2$ in contrary to estimating $16.88\;kg/cm^2$. (2) Change rate of water level : 52~33% in contrary to estimating 55~27%. (3) Note that the operational pressure of pump runs approx. 145 m, lowering 155 m of the regularity head of pump. (4) Note that the cycle of water hammering delays from 80 second to 100 second, together with easing the function of air value at the pneumatic lines. (2) Change of pressure without water hammering protection equipment : Approximate $22.86\;kg/cm^2$. The comprehensive result says that the computational fluid dynamics analysis would match well with the practical field-test. It was able to predict Max. or Min. water hammering time in a piping system. This study aims effectively to alleviate water hammering in a pipe line to be installed with air chamber at the pumping station and results in making the stability of pump system in the end.