• Title/Summary/Keyword: 손상깊이

Search Result 209, Processing Time 0.028 seconds

Tunnelling in Bangkok - Two Case Studies (방콕의 터널공사 - 두 개의 사례연구)

  • Teparaksa, Wanchai;Cho, Gye-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.7 no.2
    • /
    • pp.153-163
    • /
    • 2005
  • This paper presents two case studies for tunnelling in Bangkok: a subway tunnel site and a flood diversion tunnel site. The first case study is related to ground displacement response for dual tunnel Bangkok MRT subway. The MRT subway project of Bangkok city consists of dual tunnels about 20 km long with 18 subway stations. The tunnels are seated in the firm first stiff silty clay layer between 15-22 m in depth below ground surface. The behavior of ground deformation response based on instrumentation is presented. The back analysis based on plain strain FEM analysis is also presented and agrees with field performance. The shear strain of FEM analysis is in the range of 0.1-1% and in accordance with the results of self boring pressuremeter tests. Meanwhile, the second case study is related to the EPB tunnelling bored underneath through underground obstruction. The Premprachakorn flood diversion tunnel is the shortcut tunnel to divert the flood water in rainy season into the Choapraya river. The tunnel was bored by means of EPB shield tunnelling in very stiff silty clay layer at about 20-24 m in depth. During flood diversion tunnel bored underneath the existing Bangkok main water supply tunnel and pile foundation of the bridge, instrumentation was monitored and compared with predicted FEM analysis. The prevention risk potential by means of predicting damage assessment is also presented and discussed.

  • PDF

Development and Thermal Distribution of An RF Capacitive Heating Device (유전가열장치의 개발과 온열분포)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon;Loh, John-Kyu;Kim, Byung-Soo
    • Radiation Oncology Journal
    • /
    • v.5 no.1
    • /
    • pp.49-58
    • /
    • 1987
  • Hypertermia for the treatment of cancer has been introduced for a long time and the biological effect for the use of hyperthermia to treat malignant tumors has been well established and encouraging clinical results have been obserbed. Unfortunately, however, the engineering or technical aspects of hyperthermia for the deep seated tumors has not been satisfactory. We developed the radiofrequency capactive hyperthermia device (Greenytherm-GY8) in cooperation with Yonsei Cancer Center and Green Cross Medical Corporation. It was composed with $8{\sim}10MHz$ RF generator, capacitive electrode, matching system, cooling system, temperature measuring system and control PC computer. The thermal profile was investigated in agar phantom, animals and in human tumors, heated with capactivie RF device. Deep and homogeneous heating could be achieved in a large phantom of 25cm diameter and 19cm thick when heated with a pair of 23cm diameter electrodes, coupled to both bases of the phantom, when the size of the two electrodes was not the same, the region near the smaller electrode was preferentially heated. It was, therefore, possible to control the depth of heating by choosing proper size of electrodes. Therapeutic temperature $(42^{\circ}C{\sim}43^{\circ}C)$ could be obtained in the living animal experiments. Indications are that deep heating of humn tumors might be achieved with the capacitive method, provided that subcutaenous fat layer is cooled by temperature controlled bolus and large size of electrodes.

  • PDF

A Study on Quantitative Thickness Evaluation Using Film Density Variation in Film Radiography (Film Radiography에서 농도차를 이용한 정량적 두께 평가에 관한 연구)

  • Lee, Sung-Sik;Lee, Jeong-Ki;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.5
    • /
    • pp.356-362
    • /
    • 1999
  • Based on the assumption that film density increases exponentially with exposure in the industrial radiographic film. an equation representing the characteristic curves of industrial radiographic films and a new density-thickness relation are suggested. The accuracy and reliability of the suggested relation has been tested using radiographs of a carbon steel step wedge with known thickness variation by polychromatic X-ray and ${\gamma}$-ray ($Ir^{192}$). The experimental results were well agreed to the proposed relation in the range of film densities from 1.0 to 3.5 and it was more accurate than the conventional relation. It is also found that ${\gamma}$-ray is more effective in this purpose than polychromatic X-ray, which results in variation of effective linear absorption coefficient due to beam hardening effect as thickness increases. Therefore using the equation and experimentally determined parameters the quantitative evaluation of thickness variation is possible and it can be used to evaluate the depth of local corrosion of pressure vessels in plants.

  • PDF

The Effects of the Spat Planting Time and Environmental Factors in the Arkshell, Scapharca broughtonii Schrenck Culture (피조개(Scapharca broughtonii Schrenck) 양식시 살포시기와 환경 특성의 영향)

  • Kim, Jeong-Bae;Lee, Sang-Yong;Jung, Choon-Goo;Jung, Chang-Su;Son, Sang-Gyu
    • Journal of Aquaculture
    • /
    • v.20 no.1
    • /
    • pp.31-40
    • /
    • 2007
  • To find out the effect of the spat planting time and environmental factors in the arkshell, Scapharca broughtonii (Schrenck), we investigated the growth, survival rate of arkshell and habitat characteristics in Gamak Bay, Yeoja Bay and Saryang Island. We planted artificial spats of arkshell in Gamak Bay and Yeoja Bay at November 2004, and also planted domestic and Chinese natural spats in Saryang Island at March 2005. We measured growth, survival rate of arkshell, physiochemical parameters of the water mass (water temperature, salinity, dissolved oxygen, nutrients and chlorophyll a) and characteristics of the sediment (oxygen penetration depth, oxygen microprofiles, ignition loss and chemical oxygen demand) by monthly. The cumulative survival ratio of arkshell in Gamak Bay was the highest at December, whereas the ratio of arkshell in Yeoja Bay was recorded as 0% at October. The monthly growth rates of arkshell length in Gamak Bay and Yeoja Bay were the highest in May and the growth rate of the Korean arkshell in Saryang Island was higher than Chinese ones significantly. The high mortality (> 65%) of the arkshell in Yeoja Bay during summer probably caused by high water temperature, inflow of low salinity water, and low dissolved oxygen concentration in sediment. The concentrations of nutrient and sediment COD were considered to play an important role in the monthly survival ratio of arkshell in Gamak Bay and Sarayng Island. We suggest that the growth and mortality of arkshell might be influenced to the planting time of spat and the habitat characteristics.

Fracture Characteristics of Ductile Fiber Reinforced Cement based Composites by Collision of Steel Projectile (비상체의 충돌에 의한 고인성 섬유보강 시멘트복합체의 파괴특성)

  • Nam, Jeong-Soo;Kim, Gyu-Yong;Kim, Hong-Seop;Kim, Jung-Hyun;Han, Sang-Hyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.4
    • /
    • pp.92-100
    • /
    • 2015
  • The aim of this study is to evaluate the fracture characteristics of ductile fiber reinforced cement based composites with 1.5 volume ratio of polyvinyl alcohol and steel fiber by high velocity impact of steel projectile. We used gunpowder impact facility to evaluate the fracture characteristics of ductile fiber reinforced cement based composites by collision of steel projectile, and the impact velocity was from about 150 to 1,000m/s. The results of evaluation on the fracture characteristics of ductile fiber reinforced cement based composites were penetration grade, which is the kinetic energy more than three times of no-fiber reinforced specimen (Plain). In addition, ductile fiber reinforced cement based composites did not occurred critical damage other than the debris. In the case of mass loss, Plain specimen was proportional to kinetic energy of steel projectile, while ductile fiber reinforced cement based composites was not significantly affected by kinetic energy of steel projectile. In particular, this tendency had a close relationship with the fracture characteristics of back side of specimens, and the scabbing inhibiting efficiency of PVA specimen was higher than S specimen. In the results of verifying relationship between front and back side calculated by local damage, scabbing occurred at the region close to the back side in the ductile fiber reinforced cement based composites unlike Plain specimen. Thus, in this study, we examined principal fracture behaviors of ductile fiber reinforced cement based composites under collision of steel projectile, and verified that impact resistance performance was improved as compared to Plain specimen.

Via Cleaning Process for Laser TSV process (Laser TSV 공정에 있어서 Via 세정에 관한 연구)

  • Seo, Won;Park, Jae-Hyun;Lee, Ji-Young;Cho, Min-Kyo;Kim, Gu-Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.1
    • /
    • pp.45-50
    • /
    • 2009
  • By Laser Through-Silicon-Via process, debris and particles occur when you are forming. Therefore the research of TSV cleaning become important to remove those particles and debris. Both chemical cleaning method that uses a surfactant and physical cleaning method that uses a brush were studied with the via of $30{\mu}m$ diameter and $100{\mu}m$ depth on the 8 inch CMOS Image Sensor wafer. On the DI water and a surfactant in mixture ratio of 2:1, debris show $73{\mu}m^2$ per $0.054mm^2$. Cleaning is superior by lower mixture ratio of DI water and surfactant. In addition, It is less than 5% of debris distribution in the laser condition changed by Laser's frequency and its speed and cleaning had no effect. In the physical cleaning, there are no crack and damage when the system condition is set by $1000{\sim}3000rpm$ strip, $50{\sim}3000rpm$ rinsing, and $200{\sim}300rpm$ brushing Therefore, debris and particles can be removed by enforced chemical method and physical method.

  • PDF

Use Impacts of Trail and Campsite on Natural Environments in Mt. Palgong Natural Park (팔공산자연공원에서의 등산로 및 야영장 이용이 자연환경에 미치는 영향)

  • 권태호
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.17 no.3
    • /
    • pp.21-34
    • /
    • 1990
  • Trail and campground deteriorations and their environmental changes of soil and vegetation were studied in Tonghwa -Sa district of Mt. Palgong Natural Park through 1988 into 1989. The results are summarized as follows : 1. The bare width of trail as one of the trail condition factor was significantly greater on the more heavily used trail. Deterioration types of trail which had higher frequency for a total of 45 observations were rock exposure(42%), trail deepening(40%) and root exposure(18%) in the high order. And also sound type on which the trail was not deteriorated at all amounted to 33% of all observations. 2. Ecological changes of soil and vegatation of trailsides were not found at a uniform tendency except that soil hardness was slightly decreased from trail edge to the forest, but they could be grouped by the type of user\`s behavior and site conditions. Use impacts on the natural environment of trailside in Mt. Palgong are still far from the severe harmulness. 3. Worse damages to compground condition were appeared in Bawi-gol than Susu-gol campsite. Types of mechanically damaged trees were tree with exposed root(63% ), scared tree(43% ), mutilated tree(30 % ) and felled tree in highly frequent order. And diameter increments of trees in campsites were oppressed by the campers. 4. Tree damage types and their frequencies could be basic as a means of which grasp the bounds of user's impacts. User's disturbance on campsite extended to the distance of 70∼90m from the core of campsite at Pawi-gol and 20∼30m at Susu-gol respectively. As the tolerant trees to use impact, Lespedeza maximowiczii, Rhus trichocarpa, Acer palmatum, Rubus crataegifolius and Celastrus orbiculatus were considered.

  • PDF

An Experimental Study on the Effect of Combined X-ray and Microwave Hyperthermia on the Rectum and Urinary Bladder of Rats (흰쥐의 직장과 방광에 X-선 조사와 마이크로파 온열요법의 효과에 관한 실험적 연구)

  • Lee, Kyung-Ja;Rhee, Chung-Sik
    • Radiation Oncology Journal
    • /
    • v.4 no.2
    • /
    • pp.115-128
    • /
    • 1986
  • Hyperthermia can enhance the radiation effect as a synergistic reaction in combined X-ray irradiation and hyperthermia; hyperthermia sensitize radioresistant S-phase cells and inhibit cellular recovery from sublethal damage. We fabricated 100 watts, 2450 MHz microwave applicator for hyperthermia and planned the method and condition of heating and measured the temperature by using Agar phantom as a preliminary test. For biological examination, 102 rats were divided into 4 groups as hyperthermia, X-ray irradiation (6Gy-15Gy), combined X-ray and hyperthermia, and normal control groups. Microscopic examination of the rectum and bladder was done and the results were as followings: 1. The microwave generator with 100 watts, 2450MHz magnetron could be heating up to $40^{\circ}{\sim}50^{\circ}C$ for one hour in living tissue. 2. The thermal distribution in tissue equivalent phantom with microwave can be maintained at $40^{\circ}{\sim}44^{\circ}C$ in area of 3cm in depth and 2-10cm in diameter. 3. In Hyperthermia alone group, there was submucosal edema of the rectum but no histologic change in the urinary bladder was seen. 4. The minimal necrosis of the mucosa was appeared in the rectum and bladder after 15 days of 6 Gy and 8 Gy irradiation respectively. The minimal necrosis of the muscle layer of rectum and bladder was appeared after 15 days of 8Gy and 60days of 10Gy irradiation respectively. 5. In combined group of radiation and hyperthermia, thermal enhancement ratio (calculated at necrosis of mucosa and muscle layer) of rectum and bladder was 1.0, and it suggest that there is no change of tolerance dose of normal rectum and bladder.

  • PDF

An Experimental Study on the Thermal Property of Concrete under the Load Ratio Condition in Fire (화재시 하중재하에 따른 콘크리트의 열적특성에 관한 실험적 연구)

  • Kim, Hyung-Jun;Kim, Heung-Youl;Park, Kyung-Hun;Jung, Jae-Young;Kwan, Ki-Hyuk
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.66-74
    • /
    • 2009
  • When a fire occurs, the concrete structure's strength decreases by the increasing temperature under the fire in certain condition of constant load. And, the ratio of the axial force is changed by such decreased strength so that the structure is deformed. In this research, considering such case, we have conducted an actual fire test for the concrete lining with constant loading condition and various fire conditions. The specimen adopts the shape condition for small practical specimen defined by the EFNARC and we used 24MPa, 40MPa and 50MPa to analyze the thermal properties by the strength. The ratio of loading is imposed by a certain loading condition based on 20% and 40% of the sectional stress in concrete and MHC Fire is selected to realize the thermal impact of the concrete by rapid increasing temperature. As the result of the experiment, in the same ratio of loading, the 50MPa specimen shows more cracks and spalling as time goes on. The area damaged by the fire, according to the functional criteria of the concrete lining under the fire in ITA, does not satisfy with the standard in lack of 50mm depth from the heating surface at total 200mm lining.

A Field Test on Bearing Capacity Characteristics of Materials for Ground Cavity Restoration Based on Plate Bearing Test (평판재하시험을 이용한 공동 복구재료의 지지특성에 관한 현장실험)

  • Park, Jeong-Jun;Shin, Heesoo;Kim, Dongwook;You, Seung-Kyong;Yun, Jung-Mann;Hong, Gigwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.4
    • /
    • pp.293-304
    • /
    • 2018
  • This paper described a results of field test based on plate bearing test of the restoration material, which was developed to restore the ground cavity due to sewerage damage. The analysis of bearing capacity characteristics on the restoration materials was performed by experimental results. The results showed that the load bearing capacity in the maximum stress condition of the foundation ground is about 66%-70%, when the expansion mat is embedded at the bottom of 0.1 m and 0.2 m from the ground surface. However, The load bearing capacity of expansion mat according to embedded depth was not large. The load bearing capacity of concrete mats was about 82%-90% compared with that of ground surface, and it showed about 50% of the load bearing capacity compared with the expansion mat. As a result of analysis of allowable bearing capacity according to restoration materials, it was confirmed that the allowable bearing capacity of the expansion mat and the concrete was about 130%-150% and about 160% more than the foundation ground, respectively.