• Title/Summary/Keyword: 소화전

Search Result 43, Processing Time 0.021 seconds

Preparation of Calcium-fortified Soymilk and in Vitro Digestion Properties of Its Protein and Calcium (칼슘강화 두유의 제조 및 단백질과 칼슘의 체외 소화특성)

  • Pyun, Jin-Won;Hwang, In-Kyeong
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.995-1000
    • /
    • 1996
  • The present study was attempted to preprare calcium-fortified soymilk using proteases to improve calcium intolerance of soymilk protein and to evaluate its nutritional properties. The protease from Bacillus polymyxa was chosen as an enzyme source because it produced the least bitter taste and calcium-aggregation of soymilk among various enzymes. The optimum treatment time was 10 minutes at $50^{\circ}C$ for the best result. In vitro protein digestibility of calcium-fortified soymilks was comparable with that of control soymilk. Calcium in the digested soymilks was mostly in the ionic form and the amount of ionic calcium increased in accordance with the amount of fortified calcium in soymilk. This suggests that fortified calcium in the soymilk is bioavailable.

  • PDF

A Study on the Improvement of Disaster and Safety Management for Local Cultural Heritages (지방문화재 재난안전관리 개선방안에 관한 연구)

  • Kim, Twe-Hwan;Kim, Jung-Gon;Been, Ju-Hee
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.3
    • /
    • pp.358-366
    • /
    • 2019
  • Purpose: This paper aims to clarify the problems and to examine the improvement methods by investigating the management condition of local-designated cultural property of which management is relatively poor in comparison with state-designated cultural heritage. Method: In order to grasp the management situation of the local-designated cultural heritage, a research on cultural heritage management situation and problems will be carried out with 35 cultual heritages in Goryeong-gun. Also, the improvement methods about the property type vulnerability on the basis of interview with cultual property managers, fire-fighting officers and civil servants, etc. Results: Local cultural heritages were investigated to be very vulnerable to the fire of wooden buildings, the theft of movable cultural heritages, and the effects of wind and water damage. It is because cultural heritages are scattered over wide areas fundamentally. As the result, it has difficulty in the patrols of police officers and fire fighters, and in the situation that it lacks disaster monitoring and CCTV for countermeasures to replace them, electronic security including fire hydrant, sensors, etc and fire extinguishing facilities and so on. It is difficult for local governments managing local-designated cultural heritages to enhance their management systems directly due to their lack of budget and manpower. Conclusion: In order to strengthen disaster and safety management system for the cultural heritages designated by local governments, they have to clarify disaster countermeasure task of fire fighting, police, and cultural heritage managers prepare their manuals, and systematize them through disaster drill mainly in local autonomous governments. Also, so as to establish a surveillance system every day, they have to enhance the community for local cultural heritage manage consisting of local volunteer fire departments, local voluntary disaster prevention organizations, volunteers, etc.

Development of remote control automatic fire extinguishing system for fire suppression in double-deck tunnel (복층터널 화재대응을 위한 원격 자동소화 시스템 개발 연구)

  • Park, Jinouk;Yoo, Yongho;Kim, Yangkyun;Park, Byoungjik;Kim, Whiseong;Park, Sangheon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.167-175
    • /
    • 2019
  • To effectively deal with the fire in tunnel which is mostly the vehicle fire, it's more important to suppress the fire at early stage. In urban tunnel, however, accessibility to the scene of fire by the fire fighter is very limited due to severe traffic congestion which causes the difficulty with firefighting activity in timely manner and such a problem would be further worsened in underground road (double-deck tunnel) which has been increasingly extended and deepened. In preparation for the disaster in Korea, the range of life safety facilities for installation is defined based on category of the extension and fire protection referring to risk hazard index which is determined depending on tunnel length and conditions, and particularly to directly deal with the tunnel fire, fire extinguisher, indoor hydrant and sprinkler are designated as the mandatory facilities depending on category. But such fire extinguishing installations are found inappropriate functionally and technically and thus the measure to improve the system needs to be taken. Particularly in a double-deck tunnel which accommodates the traffic in both directions within a single tunnel of which section is divided by intermediate slab, the facility or the system which functions more rapidly and effectively is more than important. This study, thus, is intended to supplement the problems with existing tunnel life safety system (fire extinguishing) and develop the remote-controlled automatic fire extinguishing system which is optimized for a double-deck tunnel. Consequently, the system considering low floor height and extended length as well as indoor hydrant for a wide range of use have been developed together with the performance verification and the process for commercialization before applying to the tunnel is underway now.