Sprinkler Layout Optimization Based on Fire Simulation and Mathematical Programming including Installation and Damage Costs (설치비와 피해액의 정형화를 통한 화재 시뮬레이션 및 수리계획법에 기반을 한 스프링클러의 배치 최적화)

  • Lee, Ki-Jun;Shin, Young-Sup T.;Hong, Gi-Hoon;Joo, Ki-Don;Shin, Dong-Il;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.2
    • /
    • pp.52-59
    • /
    • 2012
  • The sprinkler system is regarded as the most effective fire extinguishing system. In this study, we proposed a sprinkler layout optimization framework based on fire simulation and mathematical programming. As a case study, the target space in the form of ordinary residence was set up with the size of $5.2m(L){\times}5.4m(W){\times}2.4m(H)$, and we constructed the fire scenario that polyurethane couch was ignited through carelessness. And we simulated and analyzed fire speed, temperature change and heat release rate according to the type and number of sprinklers installed. Through the formulation of installation and damage costs depending on sprinklers, the sprinkler layout showing optimal performance was resulted from mathematical programming.

A Study on Damage Effects Assessment for Asphyxiation Accident due to Malfunction of Gas Type Fire Extinguishing System (가스계 소화설비 오작동으로 인한 질식사고의 피해영향 평가)

  • Kim, Eui-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.2
    • /
    • pp.36-43
    • /
    • 2020
  • Gas system fire extinguishing equipment is a very economically useful facility, but if it is not used for a long period of time after installing the equipment, there is possibility of rupture due to corrosion of containers and operation errors of equipment systems, and this is very dangerous. However, it is impossible to experiment to check whether the equipment is operating normally. If gas is temporarily released into the enclosed space due to rupture and malfunction, it can cause serious human damage due to gas suffocation. In this study, based on the suffocation death accident of gas system fire extinguishing facility, the inflow path of released gas and the possibility of death and time to death were estimated using a 3D scan and FLACS.

Study on the effective response method to reduce combustible metal fire (금속화재 위험감소 방안에 관한 이론적 연구)

  • Nam, Ki-Hun;Lee, Jun-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.600-606
    • /
    • 2018
  • A class D fire or combustible metal fire is characterized by the presence of burning metals. Only certain metals or metal compounds are flammable, including sodium and lithium. General fire extinguishing agents, such as dry chemical powder, water-based fire extinguish agents, and carbon dioxide, cannot be used in class D fires. This is because these agents cause adverse reactions or are ineffective. In addition, the amount of usage of combustible metals is increasing due to continuous development of the semiconductor and fuel cell industries. Despite this, Korea does not have standards and laws related to combustible metal fires. This paper suggests directions of the class D fire management policies to reduce the class D fire risk and impact by analyzing the standards and laws related to class D fires and combustible metal fire cases. The factors to make laws on class D fire prevention and response systems, and management system of dry sand were determined. These results may be used to help reduce the risk of class D fires and improve the response abilities.

선박 초기 화재 대응을 위한 소화기 가상 훈련

  • Jeong, Jin-Gi;An, Yeong-Jung
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2017.11a
    • /
    • pp.243-244
    • /
    • 2017
  • 본 연구에서는 선박 초기 화재 대응을 위한 소화기 가상 훈련에 대한 제안을 한다. 가상 훈련 구현 요소로써 장비 기반 상호작용 및 설명 텍스트 시각화를 제안하고 이에 대한 시스템적 구현을 보인다.

  • PDF

A study on the move mode digestion equipment development for early fire suppression (조기 화재진압용 이동형 소화장비 개발에 관한 연구)

  • Kim, Yoo-Shik;Son, Bong-Sea;Kno, Sung-Wang;Park, Jong-Won;Joo, Jong-Kil
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.121-124
    • /
    • 2012
  • 오늘날 급속한 산업사회 및 환경변화로 인하여 불특정 다수인들이 생활하는 공간들이 고층화 및 대형화가 가속되면서 여러 가지 문제점들이 나타나고 있으며, 그중 특히 소방안전에 있어서 현실을 만족하지 못하는 부분이 적지 않다. 이러한 문제점들을 보완하기 위하여 소방장비에 적용되어지는 소방펌프의 문제점들을 보완하고 이를 적극 활용하여 새로운 소화체계의 개선과 장비 운영의 효율화를 기하고자 하며, 앞서 연구 개발된 회전용적형 펌프에 기동성과 다양성을 접목하여 기존의 소방시스템에 적극 활용하고자 한다. 그간 법적인 문제로 인하여 원심펌프 이외의 펌프를 소방장비에 적용하기에는 현실적으로 적지 않은 어려움이 있었다. 전술한 문제점을 보완하여 기동성과 접근성을 도출하여 초기화재에 보다 효과적으로 대응하는 소방장비의 접목 가능성을 제시하고자 한다.

  • PDF

Change the control system of Fire protection system in NARO Space center (나로우주센터 화재 확산 방지 장치의 제어시스템 수정)

  • Kim, Sang-Heon;Oh, Jung-Sub;Yoon, Suk-Hwan;Lee, Sung-Jun;Oh, Seung-Hyub
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.381-384
    • /
    • 2012
  • 2010년 06월 09일 소형위성발사체의 비행시험을 준비 하던 중 화재확산방지 장치가 오작동 하는 사고가 발생 하였다. 이 사고로 소화수 100톤과 소화약제 3톤이 분출 되었고, 소형위성발사체의 비행시험은 하루 지연 되었다. 오작동의 직접적 원인은 제어기 부분의 오작동으로 판단되어, 관련 제어기 및 통신라인 부품들을 모두 교체하고, 발사통제동과 발사대간의 통신선로도 이중화 하였다. 아울러 제어기의 입출력 신호를 실시간으로 기록하기 위한 장비도 추가로 설치하여 전반적인 설비의 신뢰도를 높였다.

  • PDF

공동주택에 설치된 소화 및 제연시스템에 관한 화재연동 실태분석

  • Gang, Won-Seon;Son, Bong-Se;Jeong, Jong-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.161-162
    • /
    • 2013
  • 최근에 신축되는 주상복합건축물이나 대단위 아파트단지는 지상층에서 보면 각각이 독립되어 있는 별도의 소방대상물로 보이지만, 실제로는 지하층을 통하여 연결된 하나의 소방대상물이다. 이러한 건물의 지하층에서 화재가 발생하면 열이나 연기가 다른 동으로 확산되어 피해가 커질 수 있으며, 특정동의 소방펌프에서 고장이 발생하거나 우발적인 선로합선 등으로 인하여 수신기에 이상이 발생하면 전체 동에 설치된 소방시설이 정상적으로 작동되지 않는 경우가 발생하게 된다. 화재감지기의 신호에 따라 작동되는 제연댐퍼, 준비작동식 스프링 클러설비 등이 수신기에서 연동되는 과정을 인천송도에 위치한 글로벌주상복합 단지를 토대로 하여 소화 및 제연설비의 연동실태를 분석하였다.

  • PDF