• Title/Summary/Keyword: 소형 입자영상유속계

Search Result 5, Processing Time 0.025 seconds

원형실린더의 벽면효과에 관한 연구

  • Bae, Bong-Gap;O, U-Jun;Choe, Min-Seon;Jo, Dae-Hwan;Lee, -GyeongU
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2009.10a
    • /
    • pp.134-135
    • /
    • 2009
  • 선박에서 주로 채택되는 열교환기는 쉘튜브형과 판형열교환기로 분류된다. 이 연구에서는 소형쉘튜브형 열교환기의 설계에서 중요한 요소인 냉각튜브와 벽면과의 간격에 따른 유동특성을 입자영상유속계를 이용하여 계측하였다. 연구 결과 벽면과의 거리변화에 따른 임계간격비는 0.25전후로 추정되었으며 벽면효과에 따른 정량적 데이터를 확보하였다.

  • PDF

Spray Pattern Analysis of the Injector in a Small Liquid-Rocket Engine (소형 액체로켓엔진 인젝터의 분무패턴 분석)

  • Jung, Hun;Kim, Jin-Seok;Kim, Jeong-Soo;Park, Jeong;Kim, Sung-Cho;Jang, Ki-Won
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.146-149
    • /
    • 2006
  • Spray characteristics of an injector employed in mono-propellant hydrazine thrusters were investigated by PIV(particle image velocimetry) and LDA/PDA(laser/phase Doppler anemometry) techniques. The instanteneous plane image data captured by PIV measurement were examined in order to judge a pass-fail criteria of spray injection performance according to the specific pressure supplied. LDA/PDA technique were also applied to measure the velocity and droplet size of spray were not obtained from PIV measurement. The objective of this experimental study was the clear understanding of spray characteristics as well as the derivation of injector performance to understand clearly the spray characteristics by comparing the both results.

  • PDF

Development and Application of a Miniature Stereo-PIV System (Miniature Stereo-PIV 시스템의 개발과 응용)

  • Kim, K.C.;Chetelat, Olivier;Kim, S.H.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.11
    • /
    • pp.1637-1644
    • /
    • 2003
  • Stereoscopic particle image velocimetry is a measurement technique to acquire three dimensional velocity field by two cameras. With a laser sheet illumination, the third velocity component can be deduced from out-of$.$plane velocity components using a stereoscopic matching method. Most industrial fluid flows are three dimensional turbulent flows, so it is necessary to use the stereoscopic PIV measurement method. However the existing stereoscopic PIV system seems hard to use since it is very expensive and complex. In this study we have developed a Miniature Stereo-PIV(MSPIV) system based on the concept of the Miniature PIV system which we have already developed. In this paper, we address the design and some primitive experimental results of the Miniature Stereo-PIV system. The Miniature Stereo-PIV system features relatively modest performances, but is considerably smaller, cheaper and easy to handle. The proposed Miniature Stereo-PIV system uses two one-chip-only CMOS cameras with digital output. Only two other chips are needed, one for a buffer memory and one for an interfacing logic that controls the system. Images are transferred to a personal computer (PC) via its standard parallel port. No extra hardware is required (in particular, no frame grabber board is needed).

A Study on Frequency Characteristics of Wake Flow a Circular Cylinder with Control Cylinder (제어봉이 부착된 원관 후류의 주파수특성에 관한 연구)

  • Choe, Sang-Bom;Han, Won-Hui;Cho, Dae-Hwan;Gim, Ok-Sok
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2007.11a
    • /
    • pp.177-183
    • /
    • 2007
  • Flow characteristics of the cylinder wake controlled with a small control cylinder were experimentally investigated by the PN (Particle Image Velocimetry) technique. Flow visualization of the flow around a circular cylinder was conducted in the Circulating Water Channel. The control cylinder having diameter of d=5mm, 10mm and 20mm was installed behind a circular cylinder of D=50mm. And the Reynolds number were $Re=4.9{\times}10^3,\;Re=9.9{times}10^3$ and $Re=1.9{\times}10^4$. In this study, the frequency characteristics of the controlled wake were analyzed by using spectral analysis of the measured wake velocity signals. As a result, the controlled wake had smaller vortex shedding frequency than that of circular cylinder wake by the effect of the control cylinder. Governing parameters of the flow control were d/D, and Reynolds number and they largely influenced the frequency characteristics of the cylinder wake. And vortex shedding frequency appeared most lowly at d=0.2D

  • PDF

Effects of Fuel-Injection Pressure on the Spray Breakup Characteristics in Small LRE Injector (소형 액체로켓엔진 인젝터의 분무 분열특성에 대한 연료분사압력의 영향)

  • Jung, Hun;Kim, Sung-Cho;Park, Jeong;Kim, Jeong-Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.3
    • /
    • pp.50-57
    • /
    • 2007
  • Spray characteristics of an injector in a small liquid rocket engine (LRE) is characterized by Particle Image Velocimetry (PIV) and Dual-mode Phase Doppler Anemometry (DPDA). Instantaneous plane images captured by PIV are examined for the qualitative prediction of spray breakup with the setup of evaluation technique for effect of spray angles on injector performance. DPDA is also applied in order to quantify the average velocity, turbulent intensity, SMD, and number density of spray droplets along the spray stream distance leading to precise observation of spray atomization behavior. An objective of the study is the derivation of design parameters of new injectors and the establishment of performance criteria through the clear understanding of spray characteristics.