• 제목/요약/키워드: 소음 저감

검색결과 1,673건 처리시간 0.027초

도로연변 환경시설에 의한 교통소음 저감방안에 관한 연구 (A study on Traffic Noise control by the Environmental facilities around Roadway)

  • 설증민;정용
    • 환경위생공학
    • /
    • 제3권2호
    • /
    • pp.43-60
    • /
    • 1988
  • This study was carried out to determine traffic noise level and analyze noise reduction effects of various sound protection facilities in the area of Seoul, Inch'on, Songchoo and Seoul- Busan Expressway from March to Octover, 1987. The results were as follows; 1. As compared with the environmental standards and the traffic noise level in heavy noise areas, traffic noise levels observed were shown in higher than environmental standards. The noise levels in Seoul were determined at 12.8-18.2 dB(A) in daytime and 19.0-26.9 dB (A) in nighttime. And incase of inch'on, it were 6.7-9.6 dB(A) in daytime, 7.9-18.9 dB(A) in nighttime, respectively. 2. The environmental noise level observed in the backside of protection facilities, such as apartment, soundproof barrier and houses, which were constructed in paralled to the road was lower about 3-5 dB(A) than perpendicular to theroad. Noise recuction effect of upper stairs in apartment was higher than lower stairs. 3. The predicted noise level obtained from the equation $({\triangle}L\;=\; -10\;log\;(^{I'1}/Ii)\;was\;\pm\;1dB$ (A) and the correlation coefficient (r) was 0.923. 4. The noise reduction effect in backside of apartment was measured at on sites and predicted by total noise loss equation. The predicted noise level was 60.9 dB(A) and the measured level was 60.6 dB(A), respectively. 5. The narrow width landscape less than 10m width was almost no effect for the protection of traffic noise. According to the synthesis of the above results, the noise level of the road was exceeding mostly the environmental standard in the heavy traffic areas. The counterplan should be set as well. The insulation of noise protection facilities were effective by the location with near distance from the road edge. The reduction effect of double window in apartment was represented so much. The prediction model could be applied to estimate the noise levels in the roadside as well as the effectiveness for the noise protection facilities.

  • PDF

Bifurcating을 적용한 집중권 PMLSM의 보조극 설치에 관한 연구 (A Study on Auxiliary Pole Installation of Concentrated Winding PMLSM with Bifurcating of Armature Teeth)

  • 김용재
    • 한국전자통신학회논문지
    • /
    • 제7권5호
    • /
    • pp.1067-1072
    • /
    • 2012
  • 현재 선형 전동기는 많은 연구가 진행되어 그 응용분야가 산업전반에 확대되고 있다. 이중 반송장치 분야에서 영구자석 선형 동기 전동기(Permanent Magnet Linear Synchronous Motor:이하 PMLSM)가 각광을 받고 있다. 영구자석 선형 동기 전동기는 구조적으로 간단하며 고속화 고추력화 등의 장점을 가지고 있지만 전기자를 반송경로 전장에 배치하는 지상 1차측 시스템을 장거리 반송장치에 적용하면 재료비용의 증가 및 제작시간 증가 등의 문제점이 발생한다. 따라서 전기자를 분산(불연속) 배치하는 방식이 제안되고 있다. 하지만 이러한 전기자 분산배치 방식은 구조적으로 단부가 존재하고 이러한 단부에 의해 코깅력이 발생한다. 이는 추력 맥동의 원인이 되며, 소음과 진동을 발생시킨다. 따라서, 본 연구에서는 전기자를 분산배치 할 경우 필연적으로 생기는 단부에 의한 코깅력을 저감하기 위해 Bifurcating을 적용한 집중권 PMLSM에 보조극 설치법을 제안한다. 또한 그에 따른 단부 코깅력 특성을 2차원 유한요소법(FEA)을 이용하여 분석하였다.

전기자 분산배치 집중권 PMLSM의 전기자 간격에 따른 단부 코깅력 최소화 (End Edge Cogging Force Minimization according to the Distance between Armatures of Stationary Discontinuous Armature PMLSM with Concentrated Winding)

  • 김용재
    • 한국전자통신학회논문지
    • /
    • 제8권8호
    • /
    • pp.1241-1246
    • /
    • 2013
  • 현재 일반적인 반송 장치에서는 전기자를 반송 경로 전장에 배치하는 지상 1차측 시스템이 적용되고 있다. 하지만 이러한 시스템을 장거리 반송 장치에 적용하면 초기 설치비용과 제작시간이 상승하는 문제점이 발생한다. 이러한 문제점을 해결하기 위해 전기자를 분산시켜 배치하는 방식이 제시되고 있다. 하지만 전기자 분산배치 방식은 전기자가 존재하지 않는 구간에서 외란 발생 시 가동자가 정지할 수 있으며 이 때 전기자에 의한 제어가 불가능하게 되어 가동자를 이동 시킬 수 없는 문제점을 내재하고 있다. 따라서 이러한 문제점을 해결하기 위한 전기자 간격 결정이 매우 중요하다. 또한 전기자를 분산배치 할 경우 단부가 발생하게 된다. 이는 가동자가 전기자에 진입 또는 반출 시에 코깅력을 크게 발생시켜 추력 맥동의 원인이 되며, 소음과 진동을 발생시키므로 저감하여야 한다. 따라서 본 논문에서는 전기자를 분산 배치함에 따라 존재하는 단부 코깅력을 유한요소법을 이용한 2-D 수치해석을 통해 파악하고 이를 최소화하기 위한 전기자 간격을 도출하고자 한다.

도심지 내 복층 저소음포장 설치에 따른 소음저감 사례연구 (A Case Study on Noise Reduction Effect of Two-layer Porous Asphalt Pavement in an Urban Area)

  • 정종석;소정락;이수형;양홍석
    • 한국도로학회논문집
    • /
    • 제18권5호
    • /
    • pp.49-56
    • /
    • 2016
  • PURPOSES : In this study, noise reduction effect of a two-layer porous asphalt pavement was investigated through site measurement and computer simulation. METHODS : To examine noise reduction effect, a 3 km long quiet pavement was installed by removing previous normal pavement, which had a rather low porosity. The studied site was a high-rise apartment building surrounded by the quiet pavement and Seoul ring road with heavy traffic volume, indicating relatively high background noise. RESULTS : The measurement result before and after installing the quiet pavement showed a noise reduction effect of 4.3 dB(A) at a distance of 7.5 m from the road. After validating the accuracy of simulation using SoundPLAN, the reduction in SPL(sound pressure level) at the facades by the quiet pavement was predicted by considering five different road conditions generating traffic noise from each road or in the combination of the quiet pavement and Seoul ring road. In the case of no noise from Seoul ring road, noise reduction at the facades was 4.2 dB(A) on average for 702 housing units. With background noise from Seoul ring road, however, the average SPL decreased to 2.0 dB(A). Regarding subjective response of noise, the number of housing units with a noise reduction of over 3 dB(A) was 229 out of 706 units (approximately 32%). For 77 housing units, the noise reduction was between 1~3 dB(A), while it was less than 1 dB(A) for 400 housing units. CONCLUSIONS : The overall result indicates that the quiet pavement is useful to reduce noise evenly at low and high floors compared to noise barriers, especially in the urban situation where background noise is low.

저소음 포장도로 시공에 따른 방음벽 높이 저감효과 예측 (Prediction of the Effect of Quiet Pavement on Reducing Barrier Height)

  • 양홍석;조현민;정종석;김명준
    • 한국도로학회논문집
    • /
    • 제18권5호
    • /
    • pp.31-37
    • /
    • 2016
  • PURPOSES : The purpose of this study is to evaluate the effect of the quiet pavement on reducing a barrier height by using a prediction tool called SoundPLAN. METHODS : Firstly, the prediction was carried out to evaluate the difference in the maximum noise level at a building facade between the normal and the quiet pavements without a barrier. After calculating the noise reduction effect by the quiet pavement, a comparable barrier height to obtain the same noise reduction effect with it was predicted according to designable factors including road-building distance(10 m, 20 m, 40 m) and road-barrier distance(5 m, 10 m, 20 m, 30 m). RESULTS : The result showed that within the considered designable factors, the maximum barrier height was 37 m, 52 m, and 55 m to have the same noise reduction effect by the quiet pavement reducing 1 dBA, 3 dBA, and 5 dBA, respectively. It was evaluated that the barrier height increased with the increase of the road-building and road-barrier distances. To simulate the real situation in urban areas and to evaluate the combined effect of the normal/quiet pavement and barrier, the barrier height was fixed as 6 m. It was predicted that the noise level would reduce to as low as 0.2 dBA by the combination of normal pavement and barrier. On the other hand, the combination of the quiet pavement and barrier reduced 1.2 dBA, 3.2 dBA, and 5.2 dBA, respectively, for quiet pavement reducing 1 dBA, 3 dBA, and 5 dBA. CONCLUSIONS : A guideline needs to be suggested to select appropriate noise abatement schemes by considering factors such as the roadbuilding and road-barrier distances.

3상 4선식에시 비선형 부하의 운전시 유도전동기의 특성 해석 (Characteristics Analysis of Induction Motor by Operation of Non-linear Loads under the 3-Phase 4-Wire Grid System)

  • 김종겸;박영진;이은웅
    • 조명전기설비학회논문지
    • /
    • 제20권8호
    • /
    • pp.54-62
    • /
    • 2006
  • 3상 4선식 전원공급 시스템에서 단상 및 3상 부하의 운전하에서 전압 불평형은 부하의 불평형 운전에 의해 발생되고, 전류 불평형은 떨어진 전압 품질에 의해 더욱 심해진다. 에너지 변환장치로 사용되는 여러 형태의 컨버터는 3상 4선식 배전시스템에 직접적으로 고조파 전류를 주입함으로서 고조파 왜란을 증가시킨다. 고조파 전류는 전동기 출력 토크를 감소시키고, 전동기를 과열 또는 소음을 증가시키며 회전자에 토크 맥동을 증가하여 기계적인 공진과 진동을 발생하는 등 여러 가지 부작용을 낳고 있다. 따라서 본 논문은 3상 4선식 배전시스템에서 선형 및 비선형 부하의 혼합 운전시 불평형과 고조파 성분에 의해 유도전동기의 특성 변화에 대한 연구로서 선형 단독운전, 비선형 부하 결합에 따른 특성 변화를 해석한 것으로서 단상 비선형 부하의 추가 운전시 5 고조파 필터로도 저감이 어려운 고조파로 인해 토크 맥동 횟수는 줄고 리플값은 증가함을 확인할 수 있었다.

워터젯 자유면을 이용한 암반발파 굴착공법의 효과 (Effects of free surface using waterjet cutting for rock blasting excavation)

  • 오태민;조계춘;지인택
    • 한국터널지하공간학회 논문집
    • /
    • 제15권1호
    • /
    • pp.49-57
    • /
    • 2013
  • 기존 발파를 이용한 암반굴착 공법은 효율적이나 심각한 수준의 발파진동 및 여굴/미굴을 발생시킨다. 이러한 단점을 보완하기 위해, 본 연구에서는 워터젯 절삭기술을 이용하여 터널 계획선을 따라 자유면을 형성한 후 발파하는 공법을 제안하고 있다. 제안공법은 (1) 발파진동/소음을 저감시키고, (2) 여굴/미굴을 최소화 시키고, (3) 굴착효율 극대화가 가능하다. 제안공법의 효과를 검증하기 위해 기존에 널리 쓰이고 있는 스무스 블라스팅(smooth blasting) 공법을 실험 대조군으로 설정하여 동일한 조건에서 현장실험을 수행하였다. 실험결과, 발파 진동은 최대 55% 감소하고 여굴/미굴은 거의 발생하지 않는 것으로 확인되었다. 또한 굴착효율은 기존공법에 비해 뛰어난 것으로 분석되었다. 본 연구에서 제안하고 있는 워터젯 자유면을 이용한 암반 발파공법은 도심지 굴착공사뿐만 아니라 지하구조물 구축공사에 널리 활용될 수 있을 것으로 기대된다.

75톤급 액체로켓엔진 연소기 시험설비 기본설계 (Preliminary Design of Test Facility for 75 tonf Class Liquid Rocket Engine Combustor)

  • 임병직;김종규;이광진;김문기;안규복;강동혁;서성현;한영민;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.353-358
    • /
    • 2009
  • 75톤급 액체로켓엔진의 성공적인 개발을 위해서는 각 구성품에 대한 다수의 시험이 수행되어야 하며 이러한 상황은 연소기에서도 동일하다. 하지만 한국항공우주연구원에서 운용 중인 시험설비는 75톤급 연소기를 정상 추력으로 수행하기에는 부족하다. 연소기 개발 시험에 접어들기 이전에 시험설비는 준비가 되어야 하기 때문에 시험설비의 구축이 급박하다. 본 논문에서는 이와 같은 긴급한 필요성으로 수행한 75톤급 액체로켓엔진 연소기 시험설비의 기본설계 내용을 기술한다.

  • PDF

권선방식 차이에 따른 영구자석 선형 동기 전동기의 단부 코깅력 해석 (Analysis of outlet edge cogging force at the Permanent Magnet Linear Synchronous Motor According to Difference of the Winding Method)

  • 김용재;김성진
    • 한국전자통신학회논문지
    • /
    • 제6권6호
    • /
    • pp.889-895
    • /
    • 2011
  • 영구자석 선형 동기 전동기(Permanent Magnet Linear Synchronous Motor:이하 PMLSM)는 구조적으로 간단하며 고속화 고추력화 등의 많은 장점을 가지고 있지만 전기자 권선부의 슬롯-치 구조로 인한 코깅력과 단부효과에 의한 코깅력이 발생한다. 이는 추력 맥동의 원인이 되며, 소음과 진동을 발생시킨다. 따라서, 본 연구에서는 전기자를 분산배치 할 경우 필연적으로 생기는 단부에 의한 코깅력을 저감하기 위해 PMLSM의 가동자에 보조극의 설치를 제안하였다. 또한 2차원 유한요소법(Finite Element Analysis)을 이용하여 단부 코깅력이 최소가 되는 보조극의 형태를 설계하고 전기자의 권선 방식에 따른 단부 코깅력 특성을 비교하였다.

덕트 밖에서 계산된 삽입 손실을 고려한 머플러 최적 설계 (Optimal Muffler Design Considering the Insertion Loss Calculated Outside the Duct)

  • 이종겸;오기승;이진우
    • 대한기계학회논문집A
    • /
    • 제40권5호
    • /
    • pp.497-503
    • /
    • 2016
  • 머플러의 확장방 내부에 격벽을 최적으로 배치하기 위한 음향 위상 최적화 문제를 정식화 한다. 목표 주파수에서 삽입 손실의 하한 값을 제한하며, 격벽의 부피를 목적 함수로 선정하여 최소화한다. 기존 연구에서는 투과 손실이나 덕트 내부에서 계산된 삽입 손실을 머플러의 소음 저감 특성으로 사용하였으나, 본 연구에서는 덕트 외부에서 계산된 삽입 손실을 사용한다. 음향 해석을 위해 유한 요소 모델이 사용되고, 각 유한 요소에 입사된 음파의 투과 정도는 "0"과 "1" 사이에서 연속적으로 변화하는 설계변수의 함수에 의해 결정된다. 입사파를 모두 반사시키는 강체들이 격벽을 형성한다. 목적 주파수와 허용하는 삽입손실 값에 따른 최적 위상을 비교한다.