• Title/Summary/Keyword: 소음 레벨

Search Result 366, Processing Time 0.032 seconds

Field Test and Evaluation of Noise from Wind Turbine Generators at Yongdang and Hangwon in Jeju Island (제주도 용당/행원 풍력발전기 현장 소음 실증)

  • Cheong, Cheol-Ung;Jeong, Sung-Su;Cheung, Wan-Sup;Shin, Su-Hyun;Jeon, Se-Jong;Lee, Saeng-Hui
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.818-821
    • /
    • 2005
  • The sound measurement procedures of IEC 61400-11 are applied to field test and evaluation of noise emission from 1.5 MW wind turbine generator (WTG) at Yongdang and 660 kW WTG at Hangwon in Jeju Island. Apparent sound power level, wind speed dependence and third-octave band levels are evaluated for both of WTGs. 1.5 MW WTG at Yongdang is found to emit lower sound power than 660 kW one at Hangwon, which seems to be due to lower rotating speed of the rotor of WTG at Yongdang. Equivalent continuous sound pressure levels (ECSPL) of 660 kW WTG at Hangwon vary more widely with wind speed than those of 1.5 MW WTG at Yongdang. The reason for this is believed to be the fixed blade rotating speed of WTG at Yongdang. One-third octave band analysis of the measured data show that the band components around 400-500 Hz are dominant for 1.5 MW WTG at Yongdang and those around 1K Hz are dominant for 660 kW WTG at Hangwon.

  • PDF

Towards better acoustic conditions in school buildings in Korea-a need for Korean standard for classroom acoustics (국내 교육시설의 음향기준 제정의 필요성 제고)

  • Young-Ji Choi
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.113-123
    • /
    • 2023
  • This paper describes the acoustical conditions of elementary school and high school classrooms as well as university classrooms in Korea and suggests a need for Korean acoustic standards and guidelines for classroom design. Current standards and guidelines of classroom acoustics in several countries were briefly introduced to understand their acoustical performance criteria for background noise levels and reverberation times, and noise isolation design requirements in various types of classrooms. The results of several acoustic survey of domestic classrooms in elementary school, high school, and university were described and compared to provide information of the acoustic characteristics of Korean school classrooms. The survey includes occupied and unoccupied data on the acoustical conditions, noise levels, and noise isolation performance in the classrooms. Acoustical parameter values for achieving 'good' speech intelligibility in active university classrooms were also presented.

Experimental Study on Flow Noise in a T-Junction Pipe at Different Flow Velocity (유동속도에 따른 T-접합관의 유동소음에 관한 실험적 연구)

  • Jian-bin Hu;Hou-lin Liu;Kai Wang;Guang-xin Ding;Yu-bo Jin;He-ming Liu;Hyoung-bum Kim
    • Journal of the Korean Society of Visualization
    • /
    • v.22 no.2
    • /
    • pp.55-62
    • /
    • 2024
  • Using an internal flow noise test bench, this study investigates the variation in internal flow noise at the inlet and outlet monitoring points of a DN100 T-junction pipe under different flow velocities. Results indicate that with increasing flow velocity, both the sound pressure level and total sound pressure level at the inlet and outlet monitoring points increase. The highest total sound pressure level is observed at the vertical outlet monitoring point B, followed by the horizontal inlet monitoring point A, with the lowest at the horizontal outlet monitoring point C. At a constant flow velocity, the sound pressure level at the inlet and outlet points initially increases and then decreases as frequency increases.

A study of the measurement systems implementation for the interior impulse noise (실내 충격소음 측정시스템 구현에 관한 연구)

  • Song, Kee-Hyeok;Chung, Sung-Hak
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.6
    • /
    • pp.93-100
    • /
    • 2014
  • The objective of this study is to propose the measurement system implementation method for the evaluation and measurement of the indoor-impulsive over 170 dB noise source. For the purpose of measuring impulse noise, design and implementation constructed followed subsystems of the testing center, microphone, ear simulator, head and torso simulator and so on. Measurement systems for the accuracy and reliability of impulse noise are implemented when measuring 3 ways of measurements method by the simultaneous measurement system design. For the accuracy and reliability of three mutually indoor-impulse noise measurements were compared, three kinds of measuring methods in accordance with the peak sound pressure level and octave band. Comparing the results of data, the indoor-impulse noise by analyzing a frequency characteristic was validated in difference for the statistical significance. Result are determined by the influence of the reflected wave. Therefore, the flexible size of the interior test site while interior impulse noise measurement system was constructed. Throughout this system can be affected by parameters that are the impulse noise source and the corresponding frequency-characteristic analysis to determine the spectrum of the reflected wave. And, in the near future, indoor impulse noise measurement systems for acquisition and analysis are utilized in useful data.

Regression Analysis of an Excavator Sound Power Level (굴착기의 음향파워레벨 회귀분석)

  • Gu, Jin-Hoi;Lee, Jae-Won;Seo, Chung-Youl;Jang, Seong-Ki;Choi, Kyung-Hee;Han, Jin-Seok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.3
    • /
    • pp.203-207
    • /
    • 2012
  • The noise emitted from an excavator has long been a cause of environmental disputes, while causing displeasure to the nearby residents. So, the ministry of environment adopted the construction machinery noise labeling system to encourage the construction machinery manufacturing companies to develop the low noise construction machinery voluntarily. But, as the quality of life improves, a growing number of people desire the comfortable and quite environment to live in. Under the situation, noise from the construction machinery has been a major cause for stress and complaints. When the noise dispute happened in the construction site, the sound pressure level of the construction machinery like a excavator was measured at the lot boundary of the noise victim's residence to judge how much noise damage occur. But the sound pressure level of the construction machinery is measured differently according to the acoustic environment of construction site and the measuring position, respectively, which makes it difficulty to judge whether the noise damage occur or not. As the sound power level of noise source is not affected by the acoustic environment of construction site and the measuring position, if we use the information of the sound power level, it will be easy to judge whether the noise damage occur and to establish the soundproofing measures. Therefore, we derive the sound power level regression model of the excavator to judge whether the noise emitted from the excavator damages to residents near the construction site. Also, the sound power level regression model of the excavator drawn in this paper will help construction companies to plan the noise reduction program in the construction sites.

Prediction and Reduction of Alarm Sound Propagated through Elevator Shaft (엘리베이터 샤프트를 통한 경보음 전달 예측과 개선)

  • Jeong, Jeong-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.89-96
    • /
    • 2019
  • In this study, alarm sound generated as a priority alert system propagation through an elevator shaft in apartment buildings were simulated using room acoustic simulation software. The simulations were conducted on three kinds of elevator hall plan with a different number of elevators and placement. First, the elevator shaft without sound absorption material was simulated as a condition of the present. When the distance from the alarm sound generating floor became farther, alarm sound level was decreased. However, the alarm sound level three-floor distance was about 54 dB(A)~56 dB(A) which were louder than a background sound level of typical apartment buildings. Sound absorption material placement proposed by previous studies were simulated and the alarm sound levels were decreased about 12 dB~16 dB. These levels were similar or lower than the background level of apartment buildings. From these results, it can be concluded that placing sound absorption material on the surface of the elevator shaft wall can be one of the methods to control the alarm sound as regulated in NFSC.

On an Adaptation of Announcement Sound Level in White Noise Environment (백색소음 환경에서 음성안내레벨 적응에 관한 연구)

  • Yun, Jong-Jin;Bae, Myung-Jin
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.49 no.1
    • /
    • pp.112-118
    • /
    • 2012
  • In daily life, there are many information broadcasting by using voice information systems. If surrounding noises are mixed with the information signals, the clarity of the signal become down graded too much to understand. Surrounding noises are not uniformed, but very irregular signals always changing. Therefore, it is very hard to control the output signals along with the irregular signals. This paper suggests a method to change the level of the voice information adapting to the surround noise in the white noise environment. The surround noise level is measured by subtracting the stored output voice signal from the voice signal degraded by the noise. The noise is used to estimation of SNR. And, the method to change the output level of voice signal adapting to the noise level. The suggested adaptive voice information system has the advantage to improve listeners' speech perception and to use amplifier's energy effectively.

A Response of the Shoal of Chub Mackerel ( Scomber Japonics , HOVTTYUN ) to Underwater Sound (수중음에 대한 고등어 어군의 반응)

  • 서두옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.25 no.1
    • /
    • pp.12-17
    • /
    • 1989
  • A field experiment was carried out of confirm the effect of underwater sound on the luring of fish school of chub mackerel in the coast of Idousyo Island. Underwater sound that was made use of luring of fish school was pure sound and interval pure sound which the frequencies of the sound were 150Hz and 200Hz, respectively. The results of the observation of hooking and recording paper of fish finder indicate that the effect of emitting sound at 20m in the depth of water was remarkable for the luring of fish school of chub mackerel. The vertical pure sound pressure level at 150Hz and 200Hz of the water layer that was lured the fish school of chub mackerel were 140.1dB and 146.dB at 30m, 121.0dB and 126.6dB at 70m and 141.9dB and 120.5dB at 120m in the depth of water, respectively.

  • PDF

Measurements and Data Processing for Blast Vibrations and Air-blasts (발파진동 및 발파소음의 측정 및 자료처리)

  • Choi, Byung-Hee;Ryu, Chang-Ha
    • Explosives and Blasting
    • /
    • v.33 no.3
    • /
    • pp.29-50
    • /
    • 2015
  • Safe blast criteria based on the concept of scaled distances can be obtained from the statistical analysis on measured peak particle velocity data of blast vibrations. Two types of scaled distance widely used in Korea are the square root scaled distance (SRSD) and cube root scaled distance (CRSD). In contrast to SRSD scheme, however, the function of maximum charge per delay for CRSD increases without bound after the intersection point of these two functions despite of the similar goodness of fits. To prevent structural damage that may be caused by the excessive charge in the case of CRSD, it is suggested that CRSD be used within a specified distance slightly beyond the intersection point. On the other hand, there are several attempts that predict vibration level(VL) from the peak particle velocity(PPV) or estimate VL based on the scaled distances without considering their frequency spectra. It appears that these attempts are conducted in blasting contracts only for the purpose of satisfying the environment-related law, which mainly deals with the annoyance aspects of noises and vibrations in human life. But, in principle there could no correlation between peaks of velocity and acceleration over entire frequency spectrum. Therefore, such correlations or estimations should be conducted only between the waves with the same or very similar frequency spectra. Finally, it is a known fact that structural damage due to ground vibration is related to PPV level, the safety level criteria for structures should be defined by allowable PPV levels together with their zero crossing frequencies (ZCF).

A Study on the Identification & Improvement of Dynamic Characteristics of Compressor Shell by Substructure Synthesis Method (부분구조합성법을 이용한 컴프레서 쉘의 동특성 규명 및 개선에 관한 연구)

  • Kim, Dong-Kyu;Kim, Jong-Bae;Go, Sang-Chul;Han, Kwang-Hee;Oh, Jae-Eung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.5
    • /
    • pp.99-106
    • /
    • 1996
  • The noise of a compressor is a major contributor to overall noise radiated from the refrigerator. The major source of the noise is radiated by the vibration of the compressor shell. In this study, to identify the dynamic characteristics of compressor shell, a compressor shell is divided into several components and these are analyzed with a commercial FEM(Finite Element Method) package such as MSC/NASTRAN. Using substructure synthesis method, the dynamic characteristics of the total system is identified. The coherence of each component to the total system is computed by using strain and kinetic energy. To increase the frequency of the first resonance mode which is most effective mode to the noise of the compressor shell, the improving strategy of dynamic characteristics is suggested by changing mass and stiffness of the coherence component to the first mode.

  • PDF