• Title/Summary/Keyword: 소아 방사선

Search Result 676, Processing Time 0.026 seconds

CEPHALOMETRIC ANALYSIS FOR CHILDREN WITH NORMAL OCCLUSION IN THE PRIMARY DENTITION (정상교합을 가진 유치열기 아동의 두부방사선 계측학적 연구)

  • Suh, Moon-Sun;Son, Heung-Kyu;Baik, Hyung-Sun;Choi, Hyung-Jun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.109-118
    • /
    • 2005
  • In the field of pediatric dentistry, comparison and analysis of cephalogram values of children are important fir evaluation of growth and development, and are essential to evaluate the craniofacial form and growth pattern for early diagnosis of malocclusion. For this, cephalographic norm values are important, but not many studies on the primary dentition exist. To compare the past norm values of normal occlusion in the primary dentition with current norms, preschool children, 4 to 5 years of age, with normal occlusion in the primary dentition who visited our hospital were examined. Among these children, 46 children with normal facial form and developmental status were chosen for evaluation of cephalogram values. The following results were as follows: 1. For skeletal values, the angular values showed no significant differences between males and females, and the linear values were generally greater in males than females. 2. SNA was $81.3^{\circ}$, SNB was $76.6^{\circ}$ and ANB difference was $4.7^{\circ}$. 3. The ratio for Mandibular body length to Anterior cranial base length was 0.9 : 1 for both male and female and the ratio for posterior facial height to anterior facial height was 61.4 % for male, 62.0 % for female. 4. For dental values, IMPA was $84.2^{\circ}$ and UA to SN was $90.8^{\circ}$. 5. The upper lip to Ricketts esthetic line was positioned 2.6 mm anteriorly, and the lower lip to Ricketts esthetic line was positioned 2.5 mm anteriorly.

  • PDF

THE COMPARATIVE STUDY OF CORRELATION ON HAND-WRIST WITH CERVICAL VERTEBRAE FOR SKELETAL MATURATION IN MIXED DENTITION CHILDREN WITH NORMAL OCCLUSION (혼합치열기 정상교합아동의 수완부골과 경추골의 성숙도 비교 연구)

  • Kim, Myoung-Gook;Yang, Kyu-Ho;Choi, Nam-Ki;Kim, Seon-Mi;Kim, Jee-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.3
    • /
    • pp.237-243
    • /
    • 2011
  • The purpose of study is for the certified correlations of hand-wrist radiograph with cervical vertebrae for skeletal maturation in children. Normal evaluation devices of growth stage is sexual feature, biological age, tooth development stage, height and weight. Evaluation of growth potential is very important for childhood and puberty. The skeletal developmental stages were evaluated by using the hand-wrist radiograph and cephalometric radiograph that obtained from 6 to 18 years old children. 1. Chronologic age was not more suitable indicator of skeletal development compared to Skeletal Maturity Indicators(SMI) and Cervical Vertebrae Maturation(CVM) stages. 2. SMI and CVM stages for females occurred earlier than that for male. 3. SMI 1 and 2 stages were corresponded to CVM 1; SMI 3,4 = CVM 2; SMI 5,6 = CVM 3. 4. Reproducibility and reliability of observer for SMI and CVM were excellent. This results suggest CVM stage is comparable to SMI stage in terms of evaluating the skeletal development.

A CEPHALOMETRIC STUDY BY DOWNS ANALYSIS IN THE CHILDREN WITH NORMAL OCCLUSION (정상교합아동의 Downs 분석법에 의한 두부방사선 계측학적 연구)

  • Choi, Nam-Ki;Jeong, Byung-Cho;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.3
    • /
    • pp.295-303
    • /
    • 2002
  • This study was performed to establish the cephalometric standards in Downs analysis and to compare them with other races. The lateral cephalograms of 88 Korean children (47 boys, 41 girls) with normal occlusion and acceptable profile between 7 and 11 years of age were taken and Downs analysis was done. Results were as follows: 1. Norms of Korean boys, girls and both sexes at 7, 9, 11 years of age by Downs analysis were established. 2. There were no statistically significant differences between boys and girls about ten measurements in each group, but significant differences in the occlusal plane angle, lower 1 to occlusal plane angle, interincisal angle, upper 1 to APog plane among 3 groups(p<0.05)(p<0.01). 3. Facial angle, AB plane angle, Y-axis, lower 1 to occlusal plane angle and lower 1 to mandibular plane angle showed increasing tendency whereas angle of convexity, mandibular plane angle, occlusal plane angle and interincisal angle did decreasing tendency according to aging. 4. In comparison among races, measurements in Korean children were generally larger than those of Caucasian and Greek except for small interincisal angle, but Korean were similar to Japanese, Chinese, Israeli, Negro about all measurements.

  • PDF

Dose Evaluation of Childhood Leukemia in Total Body Irradiation (소아백혈병의 전신방사선조사시 선량평가)

  • Lee, Dongyeon;Ko, Seongjin;Kang, Sesik;Kim, Changsoo;Kim, Donghyun;Kim, Junghoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.4
    • /
    • pp.259-264
    • /
    • 2013
  • Total body irradiation in the treatment of childhood leukemia, which is one of the pre-treatment with stem cell transplantation is being used, the current organization using compensators are treated. However, under the terms of the compensator organization long-term impact on the human body, it is difficult to assess directly. In this study, we use the mathematical simulation of radiation exposures body energy and the distance to the crew and the patient (source surface distance, SSD), and patients with tissue compensators change of the distance along the body of the organ doses were evaluated. As a result, the surface dose of energy 4 MV, SSD 280 cm, tissue compensators and the patient when the distance 30 cm 5.84 G / min showed the highest levels. In addition, patients with tissue compensators and the distance apart when 30 cm TBI represents the ideal dose distribution was found.

Entrance Skin Dose According to Age and Body Size for Pediatric Chest Radiography (소아 흉부촬영 시 나이와 체격에 따른 입사피부선량)

  • Shin, Gwi-Soon;Min, Ki-Yeul;Kim, Doo-Han;Lee, Kwang-Jae;Park, Ji-Hwan;Lee, Gui-Won
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.327-334
    • /
    • 2010
  • Exposure during childhood results in higher risk for certain detrimental cancers than exposure during adulthood. We measured entrance skin dose (ESD) under 7-year children undergoing chest imaging and compared the relationship between ESD and age, height, weight, chest thickness. Though it is important to measure chest thickness for setting up the exposure condition of chest examination, it is difficult to measure chest thickness of children. We set up exposure parameters according to age because chest thickness of children has correlation with age. In the exposure parameters, for chest A-P examination under 2 year-children, tube voltage (kVp) in hospital A was higher than that in hospital B while tube current (mAs) was higher in hospital B, thus the ESD values were about 1.7 times higher in hospital B. However, for chest P-A examination over 4 year-children, the tube voltage was 7 kVp higher in hospital B, the tube current were same in all two systems, and focus to image receptor distance (FID) in hospital B (180 cm) was longer than that in hospital A (130 cm), thus the ESD values were 1.4 times higher in hospital A. For same ages, the ESD values for chest A-P examinations were higher than those for chest P-A examinations. Comparing ESD according to age, ESD values were $154{\mu}Gy$, $194{\mu}Gy$ and $138{\mu}Gy$ for children under 1 year, 1 to under 4 years and 4 to under 7 years of age, respectively. These values were lower than reference level ($200{\mu}Gy$) recommended in JART (japan association of radiological technologists), however these were higher than reference values recommended by EC (european commission), NRPB (national radiological protection board) and NIFDS (national institute of food & drug safety evaluation). In conclusion, the values of ESD were affected by exposure parameters from radiographer's past experience more than x-ray system. ESD values for older children were not always higher than those for younger children. Therefore we need to establish our own DRLs (diagnostic reference levels) according to age of the children in order to optimize pediatric patient protection.

CARIES DIAGNOSIS BY DIAGNODENT'S LASER FLUORESCENCE DETECTION IN VITRO (레이저형광측정을 통한 Diagnodent의 우식진단에 관한 생체외 연구)

  • Kim, Seong-Hyeong;Lee, Kwang-Hee;Kim, Dae-Eop;Park, Jong-Seok
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.24-31
    • /
    • 2000
  • The purpose of study was to compare the laser fluorescence detection by Diagnodent(KaVo, Germany), visual inspection using dental explorers, and conventional dental radiography as diagnostic tests for dental caries. One hundred and three human premolars and molars which had no caries or fissure caries were tested by the three methods. Diagnodent scores increased as the scores of the other two tests increased(P<0.01) There were significant relationships between visual inspection scores and Diagnodent scores(Pearson 0.676, Spearman 0.694) and between radiography scores and Diagnodent scores(Pearson 0.623, Spearman 0.658) (P<0.01, all). Diagnodent test proved to have high sensitivity and low specificity and more studies are necessary to present the diagnostic criteria for progressive caries stages.

  • PDF

DENTAL CARE FORE MULTIPLE ROOTLESS TEETH : A CASE REPORT (다발성 무치근 치아에 대한 치과적 처치)

  • Lee, Mi-Sook;Lee, Keung-Ho;Choi, Yeong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.2
    • /
    • pp.316-322
    • /
    • 2001
  • Chemotherapy and radiotherapy used on pediatric oncology patients often causes dentofacial anomalies. Defects noted include tooth and root agenesis, root thinning, root shortening, localized enamel defect and maxillofacial underdevelopment. The effect of radiotherapy usually is confined to the radiation site but the effect of chemotherapy may be more wide spread becuase of its systemic distribution. Many pediatric cancers are treated with a combination of radiation and multiagent chemotherapy. Dental treatment affected by chemotherapy and radiation therapy damage to developing teeth and maxilloface includes retention of teeth, space maintenance, prosthetic considerations, requirements for oral hygiene. The following case related to multiple rootless teeth.

  • PDF

Factors Influencing Upper Airway Dimensions in Skeletal Class II Children and Adolescents: A CBCT Study (골격성 II급 소아·청소년의 상기도 공간에 영향을 미치는 요인 : CBCT 연구)

  • Kim, Byounghwa;Lee, Jewoo;Ra, Jiyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.1-11
    • /
    • 2021
  • The purpose of this study is to investigate factors influencing the upper airway dimensions in skeletal Class II children and adolescents. In total, 67 patients were selected. Airway volume and minimal cross-sectional area were three-dimensionally assessed. Craniofacial morphology and skeletal maturity were assessed on generated two-dimensional cephalograms. The measurements were analyzed using Mann-Whitney test, one-way ANOVA, Pearson's correlation, and multiple regression analysis. Upper airway dimensions were significantly smaller in pre-peak stage group, and positively associated with age. Anterior facial height and age were the most relevant factors for airway volume. Mandibular width and age were the most relevant factors for minimal cross-sectional area. Upper airway dimensions were significantly associated with age, skeletal maturity and craniofacial morphology in all three planes.

Facial Exposure Dose Assessment During Intraoral Radiography by Radiological Technologists (구내 촬영시 방사선사의 안면부 피폭선량 측정)

  • Yu, Hwan;Yang, Hanjoon
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.195-201
    • /
    • 2014
  • The study examined the changes in the decreased facial exposure dose for radiological technologists depending on increased distance between the workers and the X-ray tube head during intraoral radiography. First, the facial phantom similar to the human tissues was manufactured. The shooting examination was configured to the maxillary molars for adults (60kVp, 10mA, 50msec) and for children (60kVp, 10mA, 20msec), and the chamber was fixed where the facial part of the radiation worker would be placed using the intraoral radiography equipment. The distances between the X-ray tube head and the phantom were set to 10cm, 15cm, 20cm, 25cm, 30cm, 35cm, and 40cm. The phantom was radiated 20 times with each examination condition and the average scattered doses were examined. The rate at the distance of 40cm decreased by about 92.6% to 7.43% based on the scattered rays radiated at the distance of 10cm under the adult conditions. The rate at the distance of 40cm decreased by about 97.6% to 2.58% based on the scattered rays radiated at the distance of 10cm under the children conditions. Protection from the radiation exposure was required during the dental radiographic examination.

Awareness and Consciousness Survey of Worker's for Radiation Exposure Dose Reduction from Pediatric Brain CT Examination (소아두부 컴퓨터단층촬영검사에서 방사선피폭선량 저감화를 위한 근무자의 인식도와 의식도 조사)

  • Kim, Hyeon-Jin;Lee, Hyo-Yeong;Im, In-Chul;Yu, Yun-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.207-214
    • /
    • 2016
  • In this study, it was an investigation of the degree of awareness and consciousness of the radiology technicians about radiation protection working in the computed tomography room in Busan when the pediatric underwent brain CT scan. It was sorted by university hospital, general hospital and hospital and compared the scores of awareness and consciousness. As a result of awareness, university hospital had the highest point of 42.29 followed by general hospital and hospital of 38.43 and 34.06 respectively. On the other hand, the average score of consciousness was the highest in hospital of 29.19 followed by general hospital and university hospital of 24.68 and 21.37 respectively. It is considered to need assistance to cultivate an awareness of the radiation through refresher training and conferences, etc in order to increase the awareness of the general hospitals and hospitals for CT workers. In addition, it is also expected to pay for efforts to increase the consciousness of CT workers in university hospitals seeking the optimization of radiation protection and dose reduction of radiation exposure for the pediatric.