• Title/Summary/Keyword: 소아 물리치료 평가

Search Result 16, Processing Time 0.023 seconds

Survey About Current Status of Pediatric and Adolescent Physical Therapy: Focus on Pediatric and Adolescent Rehabilitation Hospitals in Seoul and Gyeonggi Province (소아 청소년 물리치료 실태 조사: 서울 경기 지역 소아 청소년 재활병원을 중심으로)

  • Kim, Jeong-soo;Min, Kyoung-chul
    • Therapeutic Science for Rehabilitation
    • /
    • v.12 no.4
    • /
    • pp.67-80
    • /
    • 2023
  • Objective : This study aimed to investigate the current status of physical therapy in children and adolescents. Methods : Sixty questionnaires from physical therapists treating children and adolescents with disabilities were analyzed. The questionnaire consisted of questions on physical therapy, participants, satisfaction, and the assessment of pediatric and adolescent physical therapy. Descriptive statistics and frequencies were used to investigate the current status, participants, and satisfaction. Differences between physical therapy participation difficulty, importance-ability of major aspects of pediatric and adolescent physical therapy, and therapy goal frequency were analyzed using paired T-test. Results : 11 to 15 cases (66.7%) and one-on-one treatment (95.0%) were performed independently (95.0%). The main ages of the subjects were preschool and school, the diagnoses were brain lesions and developmental delay, and treatment was conducted for up to 20 years or older. Satisfaction with pediatric and adolescent physical therapy was high (70.0%), as was the intensity of work (71.7%). Neurodevelopmental therapy, gait training, and goal-directed rehabilitation were the main treatments, and Gross Motor Function Measures of 88 and 66, respectively, were used. Respondents said that current fee system is inadequate (66.1%) and appropriate fee system is needed. Conclusion : This study extensively investigated the content of and factors related to pediatric and adolescent physical therapy. Based on the current situation, efforts to improve the expertise and continuity of pediatric and adolescent physical therapists and apply the latest treatment techniques are required.

Changes in Activities of Daily Living of Children with Spastic Cerebral Palsy According to Gross Motor Function Classification System After One Year of Physical and Occupational Therapy (물리 및 작업치료 1년 후 대동작 기능분류체계에 따른 경직성 뇌성마비 아동의 일상생활동작 변화)

  • Lee, Kwon-Woo;Kim, Won-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.431-440
    • /
    • 2019
  • This study was conducted to investigate changes in activities of daily living (ADLs) according to the Gross Motor Function Classification System (GMFCS) after one year of physical and occupational therapy and to compare the responsiveness of ADL tools. A total of 48 children with spastic cerebral palsy participated in the study. The GMFCS, Functional Independence Measure for Children (WeeFIM), and Pediatric Evaluation of Disability Inventory (PEDI) were measured. The results showed that the GMFCS was significantly correlated with the PEDI (p<0.05), while there was a significant difference in the change of ADLs measured by the PEDI, but not the WeeFIM. There was a significant difference in the changes in ADLs according to the GMFCS, and the change in ADLs in the high functional level group was significantly higher than in the low functional level group (p<0.05). After physical and occupational therapy, the degree of improvement of ADLs varied according to the GMFCS, but seemed to be improved in a clinically meaningfully way. The PEDI is sensitive to changes in ADLs, so it may be used widely in clinical practice.

The Distribution of Pediatric Patients According to Accessibility to Dental Facilities in Pusan National University Dental Hospital (치과의료기관 접근성에 따른 부산대학교 치과병원 소아치과의 신환 분포)

  • Haena, Lee;Soyoung, Park;Jonghyun, Shin;Taesung, Jeong;Eungyung, Lee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.4
    • /
    • pp.368-378
    • /
    • 2022
  • The purpose of this study was to analyze the accessibility to dental facilities and the differences in chief complaints of new patients who visited Pusan National University Dental Hospital. We collected information from electronic medical records for 1,820 new patients. The accessibility was analyzed by measuring the distance from the patient's house to the dental facilities. The distance was categorized into 10 km sections, and the presence or absence of a local pediatric dental clinic within 10 km of the patient's house was also categorized. As the distance between the house and Pusan National University Dental Hospital increased, the proportion of patients who visited for dental caries decreased, and orthodontic treatment increased. Dental caries accounts for 27.9% of less than 10 km and 20.5% over 30 km. Orthodontic treatment accounts for 25.4% within 10 km and 27.3% more than 30 km away. The presence or absence of a local pediatric dental clinic within 10 km did not significantly affect the distribution of chief complaints. This study can be used as basic research data to establish effective treatment measures that can improve the physical and geographical accessibility of patients visiting pediatric dentistry.

Retrospective Study of Survival Rates According to the Type of Dental Restoration of Proximal Caries in Primary Molars (치과용 수복재료에 따른 유구치부 인접면 수복물의 생존율연구 : 후향적연구)

  • Jih, Myeongkwan;Lee, Sangho;Lee, Nanyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.3
    • /
    • pp.249-256
    • /
    • 2015
  • Restorative dental materials have advanced rapidly, with improved physical properties that improve survival rates. Accordingly, various materials can be selected. Amalgam, composite resin, glass-ionomer cement, and preformed stainless steel crowns have all been used widely for the restoration of dental caries in primary molars. The various dental materials used to treat proximal caries in the primary molars have distinct advantages and disadvantages. However, few studies have examined their survival rates. This retrospective study examined the 2-year survival rates of more than 700 class II restorations of proximal caries in primary molars clinically and radiologically according to the type of restoration. The study results should help in the selection of class II restorations for molars, one of the biggest concerns of pediatric dentists.

Relationship Between Function Classification Systems and the PEDI Functional Skills in Children With Cerebral Palsy (뇌성마비 아동에서 기능분류체계와 소아장애평가척도의 기능적 기술 사이 관련성)

  • Park, Eun-Young;Kim, Won-Ho
    • Physical Therapy Korea
    • /
    • v.21 no.3
    • /
    • pp.55-62
    • /
    • 2014
  • This study investigated the relationship between function classification systems and the Pediatric Evaluation of Disability Inventory (PEDI) functional skills in children with cerebral palsy (CP). Two hundred and eleven children with CP participated in this study. The Korean-Gross Motor Function Classification System (K-GMFCS), Korean-Manual Ability Classification System (K-MACS), Korean-Communication Function Classification System (K-CFCS), and self-care, mobility, and social function domains of the Korean-Pediatric Evaluation of Disability Inventory (K-PEDI) functional skills were measured by physical therapists or occupational therapists. All of the function classification systems were significantly correlated with PEDI functional skills ($r_s$=-.549 to -.826) (p<.05). Especially, K-GMFCS, K-MACS, and K-CFCS were correlated significantly with mobility, self-care, and social function, respectively. Using stepwise multiple regression analysis, we established that K-GMFCS, K-MACS, and K-CFCS were predictors of self-care skills (74.3%) and mobility skills (79.5%) of the K-PEDI (p<.05). In addition, K-CFCS and K-MACS were predictors of social function (65.9%) of the K-PEDI (p<.05). The information gathered in this study using the levels measured in the function classification systems may be useful to clinicians for estimating the PEDI functional skills in children with CP.

Implementation and Evaluation of the Electron Arc Plan on a Commercial Treatment Planning System with a Pencil Beam Algorithm (Pencil Beam 알고리즘 기반의 상용 치료계획 시스템을 이용한 전자선 회전 치료 계획의 구현 및 정확도 평가)

  • Kang, Sei-Kwon;Park, So-Ah;Hwang, Tae-Jin;Cheong, Kwang-Ho;Lee, Me-Yeon;Kim, Kyoung-Ju;Oh, Do-Hoon;Bae, Hoon-Sik
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.304-310
    • /
    • 2010
  • Less execution of the electron arc treatment could in large part be attributed to the lack of an adequate planning system. Unlike most linear accelerators providing the electron arc mode, no commercial planning systems for the electron arc plan are available at this time. In this work, with the expectation that an easily accessible planning system could promote electron arc therapy, a commercial planning system was commissioned and evaluated for the electron arc plan. For the electron arc plan with use of a Varian 21-EX, Pinnacle3 (ver. 7.4f), with an electron pencil beam algorithm, was commissioned in which the arc consisted of multiple static fields with a fixed beam opening. Film dosimetry and point measurements were executed for the evaluation of the computation. Beam modeling was not satisfactory with the calculation of lateral profiles. Contrary to good agreement within 1% of the calculated and measured depth profiles, the calculated lateral profiles showed underestimation compared with measurements, such that the distance-to-agreement (DTA) was 5.1 mm at a 50% dose level for 6 MeV and 6.7 mm for 12 MeV with similar results for the measured depths. Point and film measurements for the humanoid phantom revealed that the delivered dose was more than the calculation by approximately 10%. The electron arc plan, based on the pencil beam algorithm, provides qualitative information for the dose distribution. Dose verification before the treatment should be mandatory.

Estimation of Jaw and MLC Transmission Factor Obtained by the Auto-modeling Process in the Pinnacle3 Treatment Planning System (피나클치료계획시스템에서 자동모델화과정으로 얻은 Jaw와 다엽콜리메이터의 투과 계수 평가)

  • Hwang, Tae-Jin;Kang, Sei-Kwon;Cheong, Kwang-Ho;Park, So-Ah;Lee, Me-Yeon;Kim, Kyoung-Ju;Oh, Do-Hoon;Bae, Hoon-Sik;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.269-276
    • /
    • 2009
  • Radiation treatment techniques using photon beam such as three-dimensional conformal radiation therapy (3D-CRT) as well as intensity modulated radiotherapy treatment (IMRT) demand accurate dose calculation in order to increase target coverage and spare healthy tissue. Both jaw collimator and multi-leaf collimators (MLCs) for photon beams have been used to achieve such goals. In the Pinnacle3 treatment planning system (TPS), which we are using in our clinics, a set of model parameters like jaw collimator transmission factor (JTF) and MLC transmission factor (MLCTF) are determined from the measured data because it is using a model-based photon dose algorithm. However, model parameters obtained by this auto-modeling process can be different from those by direct measurement, which can have a dosimetric effect on the dose distribution. In this paper we estimated JTF and MLCTF obtained by the auto-modeling process in the Pinnacle3 TPS. At first, we obtained JTF and MLCTF by direct measurement, which were the ratio of the output at the reference depth under the closed jaw collimator (MLCs for MLCTF) to that at the same depth with the field size $10{\times}10\;cm^2$ in the water phantom. And then JTF and MLCTF were also obtained by auto-modeling process. And we evaluated the dose difference through phantom and patient study in the 3D-CRT plan. For direct measurement, JTF was 0.001966 for 6 MV and 0.002971 for 10 MV, and MLCTF was 0.01657 for 6 MV and 0.01925 for 10 MV. On the other hand, for auto-modeling process, JTF was 0.001983 for 6 MV and 0.010431 for 10 MV, and MLCTF was 0.00188 for 6 MV and 0.00453 for 10 MV. JTF and MLCTF by direct measurement were very different from those by auto-modeling process and even more reasonable considering each beam quality of 6 MV and 10 MV. These different parameters affect the dose in the low-dose region. Since the wrong estimation of JTF and MLCTF can lead some dosimetric error, comparison of direct measurement and auto-modeling of JTF and MLCTF would be helpful during the beam commissioning.

  • PDF

The Correlation between Motor Capacity, Capability, and Performance in Children with Cerebral Palsy (뇌성마비 아동의 능력, 수행능력, 수행 간 상관관계)

  • Kim, JangGon;Kim, TaeYoon
    • 재활복지
    • /
    • v.20 no.3
    • /
    • pp.125-139
    • /
    • 2016
  • The aim of this study was to distinguish 3 concepts(capacity, capability, and performance) for the motor activities of children with cerebral palsy(CP) and examinate relation between capacity(can do in a standardized environment), capability(can do in daily environment), and performance(does do in daily environment). Cross-sectional analysis with a assessment record of children with CP (n=40; 19males, 21 females; mean age 6y 6mo, SD 3y 8mo) was performed. Levels of severity according to the Gross Motor Function Classification System(GMFCS) included level1(13%), level2(10%), level3(43%), level 4(33%), and level 5(3%). Motor activities capacity was assessed by the Gross Motor Function Measure (GMFM-66). Capability and performance were assessed using 2 scales(functional skill, caregiver assistance) of the Pediatric Evaluation of Disability Inventory(PEDI). Correlations between capacity and capability was 0.811(p < .05), and between capability and performance were high(r=0.711, p < .05). And the correlation between capacity and performance is the lowest(r=0.711, p < .05). Motor performance levels are only partly reflected by the motor capacity and motor capability levels in children with CP. Because performance is influenced by Contextual factors (particularly, social factors such as family function). This study suggests that it is necessary to distinguish and evaluate the capacity, capability, and performance in children with cerebral palsy.

Dosimetric Influence of Implanted Gold Markers in Proton Therapy for Prostate Cancer (전립선암에 대한 양성자치료에서 금마커에 의한 방사선 선량분포의 영향)

  • Kwak, Jung-Won;Shin, Jung-Wook;Kim, Jin-Sung;Park, Sung-Yong;Shin, Dong-Ho;Yoon, Myong-Geun;Park, So-Ah;Kim, Dong-Wook;Lim, Young-Gyeung;Lee, Se-Byeong
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.291-297
    • /
    • 2010
  • This study examined the dosimetric influence of implanted gold markers in proton therapy and the effects of their positions in the spread-out Bragg peak (SOBP) proton beam. The implanted cylindrical gold markers were 3 mm long and 1.2 mm in diameter. The dosimetric influence of the gold markers was determined with markers at various locations in a proton-beam field. Spatial dose distributions were measured using a three-dimensional moving water phantom and a stereotactic diode detector with an effective diameter of 0.5 mm. Also, a film dosimetry was performed using Gafchromic External Beam Treatment (EBT) film. The GEANT4 simulation toolkit was used for Monte-Carlo simulations to confirm the measurements and to construct the dose-volume histogram with implanting markers. Motion data were obtained from the portal images of 10 patients to investigate the effect of organ motions on the dosimetric influence of markers in the presence of a rectal balloon. The underdosed volume due to a single gold marker, in which the dose was less than 95% of a prescribed amount, was 0.15 cc. The underdosed volume due to the presence of a gold marker is much smaller than the target volume. However, the underdosed volume is inside the gross tumor volume and is not smeared out due to translational prostate motions. The positions of gold markers and the conditions of the proton-beam field give different impacts on the dose distribution of a target with implanted gold markers, and should be considered in all clinical proton-based therapies.

Error Analysis of Delivered Dose Reconstruction Using Cone-beam CT and MLC Log Data (콘빔 CT 및 MLC 로그데이터를 이용한 전달 선량 재구성 시 오차 분석)

  • Cheong, Kwang-Ho;Park, So-Ah;Kang, Sei-Kwon;Hwang, Tae-Jin;Lee, Me-Yeon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Oh, Do-Hoon
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.332-339
    • /
    • 2010
  • We aimed to setup an adaptive radiation therapy platform using cone-beam CT (CBCT) and multileaf collimator (MLC) log data and also intended to analyze a trend of dose calculation errors during the procedure based on a phantom study. We took CT and CBCT images of Catphan-600 (The Phantom Laboratory, USA) phantom, and made a simple step-and-shoot intensity-modulated radiation therapy (IMRT) plan based on the CT. Original plan doses were recalculated based on the CT ($CT_{plan}$) and the CBCT ($CBCT_{plan}$). Delivered monitor unit weights and leaves-positions during beam delivery for each MLC segment were extracted from the MLC log data then we reconstructed delivered doses based on the CT ($CT_{recon}$) and CBCT ($CBCT_{recon}$) respectively using the extracted information. Dose calculation errors were evaluated by two-dimensional dose discrepancies ($CT_{plan}$ was the benchmark), gamma index and dose-volume histograms (DVHs). From the dose differences and DVHs, it was estimated that the delivered dose was slightly greater than the planned dose; however, it was insignificant. Gamma index result showed that dose calculation error on CBCT using planned or reconstructed data were relatively greater than CT based calculation. In addition, there were significant discrepancies on the edge of each beam while those were less than errors due to inconsistency of CT and CBCT. $CBCT_{recon}$ showed coupled effects of above two kinds of errors; however, total error was decreased even though overall uncertainty for the evaluation of delivered dose on the CBCT was increased. Therefore, it is necessary to evaluate dose calculation errors separately as a setup error, dose calculation error due to CBCT image quality and reconstructed dose error which is actually what we want to know.