• Title/Summary/Keyword: 소방설비

Search Result 595, Processing Time 0.022 seconds

A Comparative study of the performance for hose reel hydrant system and indoor hydrant system (호스릴옥내소화전설비와 옥내소화전설비의 성능 비교 연구)

  • Nam, Jun-Seok;Baek, Chang-Sun;Kim, Joon-Bae;Kang, Tae-Young;Park, Sung-Ock;Han, Jae-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.104-107
    • /
    • 2008
  • The performance of hose reel hydrant system and indoor hydrant system was tested comparatively. At that result, a hose reel hydrant system are excellent and have the same performance as indoor hydrant system. If hose reel hydrant system has the performance that pressure is more than 0.17 MPa and flow-rate is over 130 LPM at the nozzle, it can be substituted for indoor hydrant system.

  • PDF

Quantity of the Agent in the Piping System of Low Pressure Carbon Dioxide Extinguishing Systems (저압이산화탄소 소화설비의 방출배관내 약제량)

  • Kim, Wee-Kyong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.136-139
    • /
    • 2011
  • 국가화재안전기준 107 및 107A에서 할로겐화합물 소화설비와 청정소화약제 소화설비 설계시 하나의 방호구역을 담당하는 저장용기의 소화약제의 체적합계보다 소화약제의 방출시 방출경로가 되는 배관(집합관을 포함한다)의 내용적의 비율이 설정된 값 이상인 경우 당해 방호구역에 대한 설비는 별도의 독립방식으로 하도록 요구하고 있다. 이산화탄소 소화설비의 경우에는 이산화탄소의 증기압이 충분히 높으므로 방출배관의 용적에 대한 제한사항이 포함되어 있지 않으나 저압이산화탄소 소화설비의 경우 약제의 저장온도가 낮으므로 방출시 기화되어 설계시 의도한 방출량을 만족시키지 못할 수 있다. 본 논문에서는 저압이산화탄소 소화설비에 대한 방출배관 용적 제한 필요성에 대하여 논의하였다.

  • PDF

Measures applied for fire protection system of Light gauge strainesss steel pipe and the fittings for ordinary piping (일반배관용 스테인리스강관 및 이음쇠의 소화설비 적용 방안)

  • Nam, Jun-Seok;Choi, Jin-Jong;Kim, Yong-Ho;Park, Joo-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.83-86
    • /
    • 2011
  • 옥내소화전설비, 스프링클러설비 등 수계소화설비에 일반배관용 스테인리스강관과 그 연결에 필요한 이음쇠의 사용가능성을 적용사례, 내식성 등을 통해 확인하였고, 기존 수계소화 설비의 배관에 대한 개선방안을 도출하였다. 일반배관용 스테인리스강관 및 이음쇠는 국내의 경우 수도용으로 활발히 사용되고 있으며, 독일 영국 일본 미국 등의 수계소화설비에 사용되고 있음을 확인할 수 있었다. 강관과 이음쇠의 연결상태에서 내식성을 확인하기 위해 0.5 %와 3.5 %의 소금물을 관내에 주입한 후 28일 보관한 결과 이상이 없음을 확인하였다. 또한, 기존에 설치되어있는 수계소화설비는 배관계의 온도차에 의한 보상방법이 되어있지 않아 작동물질의 열팽창에 따라 강관, 이음쇠의 파손이 발생할 수 있음을 확인하었다.

  • PDF

A Study of the Suppression System based on the Fire Protection System the Korea Cultural Property due to the Forest Fire -About Water Mist System- (산림화재로부터 문화재를 보호하는 소방시설에 관한 연구 -미분무수설비를 중심으로-)

  • Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.44-51
    • /
    • 2007
  • Most of the Korea temples of cultural property are wooden buildings and easy combusted. They are often located in mountain area far away from the city. It is very difficult to approach the fight area. The putting out is very difficult in the initial fire time. And for protecting the cultural property in the long-term continuous fire source there are some restrictions in water source and suppression system. In this paper the initial putting out fire due to the forest fire and the protection of cultural property in the long-term continuous fire source were researched. The improved project about fire control facilities of the Korea cultural property was proposed. In the proposed project the facilities using Water mist which can reduce more loss than existing facilities using water are applied. In view of the topographic position the method of eliminating the energy of combustibles and wall for cutting off the heat in the fire control facilities are also mentioned.

A study on the penetration of the builing fire compartment (방화구획 관통부에 관한 연구)

  • Park, Jong-Jin;Yoon, Myong-O
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.37-41
    • /
    • 2010
  • 스프링클러설비와 방화구획 구성요소는 화재시 매우 중요한 역할을 한다. 그러나 기존에 15층이하 아파트는 스프링클러설비가 없어 화재시 방화구획에 의존해야 되는데 방화구획 관련 설계, 시공, 감리가 미비하여 화재에 쉽게 노출되어 있다. 설비슬리브, 전선관, 덕트등이 방화구획으로 되어 있는 부분을 관통하는 경우 그틈을 시멘트모르타르나 기타 불연재료로 메우도록 규정하고 있으나 화재발생시 관통부를 메운 재료의 내화성능 부실, 균열, 탈락 등으로 화재안전성이 떨어진다. 현장에서의 설계, 시공, 감리등 대응하는 자세가 너무 허술하다. 설계에 방화댐퍼, 관통부 틈새의 내용이 반영 되지 않고 건축, 기계, 전기, 통신, 소방등 각 분야의 허가 도면에 도장이 날인되어 나타난다. 시공자는 잘못된 설계도면을 가지고 허가 도면이라며 도면되로 시공한다. 또한 실리콘, 우레탄폼등을 방화구획 관통부 틈새에 주입하며, 작업자도 비숙련자로서 개념도 없이 방화용실란트와 우레탄폼을 혼용해가며 작업을 한다.

  • PDF

A Study on the Design Program Development of the Carbon Dioxide Fire Extinguishing System Using an Optimization (최적화 기법을 이용한 이산화탄소 소화설비의 설계프로그램 개발에 관한 연구)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.1-9
    • /
    • 2014
  • In this study, it was developed to the design program optimization the design factors of the carbon dioxide fire extinguishing system on the basis of design theory for the carbon dioxide fire extinguishing system, national emergency management agency (NEMA) notice No. 2012-11, KS B 6261 and steepest descent method of optimization. The design program was developed to C++ compiler based on established the logic and algorithms and was to operate on the Windows operating system. The optimization of design factors for the carbon dioxide fire extinguishing system are minimized subject to constraint on agent flow rate, emission time and design variables (pipe size etc.). It was verified to the design program performance for test system, and it was provided to the foundation for optimal design in fire fighting field. Also, it is considered to improve the efficiency of the fire extinguishing system and to maximize of fire suppression as the construction of the carbon dioxide extinguishing system based on the optimal design factors.

낙산사 소실과 화재예방을 위한 조계종의 장기 대책

  • Do, Yun-Su
    • 방재와보험
    • /
    • s.108
    • /
    • pp.12-17
    • /
    • 2005
  • 고색창연한 전각들이 거센 불기운에 주저앉고, 천 년 고찰의 역사가 불타버린 낙산사의 참혹한 모습에 안타까움과 함께 각종 재해에 무방비로 노출되어 있는 전국의 사찰과 문화유산에 대한 경각심을 일깨워야 할 때이다. 이에 일반에 공개되어 늘 화인과 접촉되어 있는 문화재의 특수성을 고려한 소방설비 대안 마련과 새로운 소방개념의 도입을 통해 문화재 보존의 허점을 개선해 나가고자 한다.

  • PDF

The Study on the Legal Improvement for Fire Protection in Wooden Architectural Heritage (목조건축 문화재의 화재방호를 위한 법규 개선에 관한 연구)

  • Kim, Dong Cheol;Roh, Sam Kew;Ham, Eun Gu
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.19-26
    • /
    • 2015
  • This study covers securing legal systems and institutions regarding the standards for installing fire prevention facilities to prevent fire on wooden architectural heritage. Conflicts among relevant laws were revealed and problems related to fire prevention performance, technical standards, responsibilities, etc. in the process of establishing legal fire prevention equipment and the equipment for self-extinguishing were identified through pondering over current legal systems of fire prevention facilities. To resolve the problems, at least the principle to preserve original shapes of wooden architectural heritage should be secured even though fire prevention facilities are installed and the installation process should be regulated by laws considering features of fire on wooden architectural heritage so that fire prevention performance can be guaranteed. The directions to improve installing system through legalization of design, construction, and audit review institutions and legalization of the technical standards for fire prevention facilities were suggested to guarantee performance when establishing fire prevention facilities for wooden architectural heritage.

Seismic Performance Evaluation of Sprinkler Facilities throughout Shaking Table Test (진동대 실험을 통한 스프링클러 설비의 내진성능 평가)

  • Nam, Min-Jun;Park, Seung-Hee;Kim, Dong-Jun;Yoon, Jong-Ku;Seo, Choon-Gyo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.54-57
    • /
    • 2012
  • 지진에 의한 2차 피해 중 화재로 인한 피해가 거의 대부분이다. 따라서, 소화설비의 내진설계는 반드시 필요하며 소화능력을 유지해야 한다. 본 연구에서는 진동대 실험을 통하여 스프링클러 설비의 내진성능을 평가하였다. 스프링클러 설비의 내진성능을 평가하기 위하여 일반 설비와 내진처리가 된 설비를 동시에 시공하여 그 성능을 평가하였다. 또한, 시설물의 거동특성을 파악하기 위하여 시설별 변위응답, 가속도 응답, 가속도 응답스펙트럼을 통하여 시설물에 대한 내진성능을 평가하였다.

  • PDF

Development of Vacuum Sprinkler Extinguishing System (부압식 스프링클러설비)

  • Oh, Ju-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.61-66
    • /
    • 2011
  • 부압식 스프링클러 설비는 우리나라에서 일반적으로 사용되고 있는 준비작동식이나 건식 또는 습식 스프링클러 설비의 2차측 배관내의 압력을 부압(진공)상태로 유지시켜 오작동(스프링클러 헤드의 파손 또는 배관의 누수) 시에 발생되는 소화수의 누수를 진공압(-0.05~-0.08MPa)으로 흡입하는 구조로 설계되어 수손피해에 대한 위험도를 제거 하여 기존의 스프링클러 시스템의 문제점을 해결 할 수 있는 획기적인 기술로 볼 수 있다. 또한 부압식 스프링클러 설비는 습식, 준비작동식에 해당하는 시설에 모두 적용이 가능하며 매년 국내, 외에서 건설되는 모든 대상물에도 설치가 가능하며 기존 설비된 건물에도 손쉽게 적용이 가능하여 앞으로 IT관련 산업, 반도체 제조공장, 호텔, 학교, 병원, 관공서, 지하철 역사, 정밀가공 제조설비 등 특히 내진설계에 적용되고 있는바 그 적용성이 무궁무진한바 본 부압식 스프링클러 시스템의 연구를 통한 확대에 대한 가능성은 무한할 것으로 예상된다.

  • PDF