• Title/Summary/Keyword: 소방도로

Search Result 308, Processing Time 0.021 seconds

Using AHP to Develop a Rehabilitation Room Management Model for Fire Officers at Disaster Sites (재난현장 소방공무원의 회복실 운영모델 개발)

  • Yim, Dong-Kyun;Chae, Jin
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.115-124
    • /
    • 2020
  • The purpose of this study was to provide an operational model of the rehabilitation room for fire officers at disaster sites to improve the safety and resilience of fire officers. Therefore, we analyzed the operation related elements of the rehabilitation room-such as overseas rehabilitation room operation cases and previous studies- and managed different factors including, but not limited to, management and human resources, equipment and facility, and accessibility and convenience factors; afterward, the relative importance and importance of sub-layers in each field were measured. The priority of items for the operation of the rehabilitation room for fire officers at disaster sites was elucidated; after expert analysis, it was found that human resources were the most crucial factor. Finally, it was found that, in descending order, accessibility and convenience, administrative, equipment, and facility factors were also essential. Based on this, we proposed a rehabilitation room operation guideline for disaster sites.

Impact of Earthquake Response Perception on Fire officials on Organizational Citizenship Behavior (소방공무원의 지진 대응인식이 조직시민행동에 미치는 영향)

  • Kim, JeeYun
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.343-352
    • /
    • 2020
  • Purpose: This study identifies the impact on composition of the firefighting organization, fire command ability, and public opinion operation on organizational citizenship behavior for fire officials to respond to the earthquake disaster, and provides practical implications as basic data for firefighting organizations to cope with the earthquake disaster. Method: Questionnaire survey was performed for 159 fire officials, and the surveyed data was statistically analyzed by using SPSS 22.0 program. Result: First, the results of the verification of the hypothesis showed that the composition of the fire organization, firefield command ability and public opinion operation have a positive impact on organizational citizenship behavior. Second, the relative contribution of independent variables to the dependent variables was identified in the order of composition of fire organization, fire command ability and public opinion operation. Conclusion: The implications of this study suggested from a practical perspective that the government needs to organize firefighting organizations, develop firefield command ability and operate public opinion in advance in order to respond to earthquakes.

A Study on the State of Utilizing Fire Facility in Fire Fighting (소방시설의 화재진압 활용실태에 관한 연구)

  • Lee, Chang-Seop
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.144-148
    • /
    • 2011
  • In this study I investigated that fire fighters utilize fire facilities properly or not, and found problems and solutions with interview and questionnaire. Fire fighters tend to utilize portable instruments. 62% of fire fighters have used fire facilities which is installed in building. The most useful facility is indoor fire hydrant, 42% of fire fighters have used that. The primary reason to avoid to use facility is that they think the facilities are not good at quick response. Almost fire fighters want improvement to enhance utilizing fire facilities. Finally in the fire scene, commander's initiative, fire fighter's ability, easiness of utilizing fire facilities, and fire fighter's creditibility about fire facilities are related to the degree of utilizing fire facilities.

침대매트리스 실물화재평가의 열방출율 측정에 대한 Uncertainty 연구

  • Park, Gye-Won;Jeong, Jae-Gun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.103-104
    • /
    • 2013
  • 본 연구에서는 침대 매트리스에 대해서, 실물규모 화재시험을 이용한 열방출율(Heat release rate: 이하 HRR)을 측정할 때의 불확도(Uncertainty) 산정을 위한 정보제공을 목적으로 함. 실제 실험데이터를 바탕으로 불확도에 영향 미치는 개별요인들을 도출한 개별 요인들의 합성을 통해 불확도를 산정하였음.

  • PDF

The Effects of Job Stress with Depression and Fatigue of Firemen (소방관의 직무스트레스가 우울 및 피로에 미치는 영향)

  • Kim, Kwang-Seok;Park, Jong;Park, Bu-Yeon;Kim, Sung-Gil;Hwang, Eun-Yeong
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.3
    • /
    • pp.223-231
    • /
    • 2014
  • This study aims to identify job stress of firemen and the relations between their job stress, depression and fatigue, targeting firemen who are working for local fire stations. We interviewed the subjects using a short-answer type questionnaire or a online questionnaire. The data collected were analysed with a use of SPSS WIN 15.0 for confidence analysis, correlation analysis, step-by-step multi-regression analysis, and covariance structure analysis(CSA). This study result tasks and emotional stress had a direct effect on depression and fatigue. Therefore, this study suggests that governmental management should be provided for firemen that are classified as a high-risk group in occupational characteristics. Above all, the causes of stress should be diagnosed, its management goals should be set, and effective intervention programs should be provided.

Fire Hazard Analysis on Alternative AC Diesel Generator Building Newly Built In Nuclear Power Plant Operation (가동중 원자력발전소에 신축된 대체교류 디젤발전기건물 화재위험도분석)

  • Kim, Jeung-Wook;Choi, Jung-Sub;Jeong, Jae-Geun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.222-226
    • /
    • 2011
  • 원자력발전소 화재위험도분석이후 재평가 10년 주기가 도래하기 전에 대체교류 디젤발전기건물이 신축됨에 따라 동 건물에 대한 화재위험도분석이 필요하게 되었다. 본 논문에서는 국내 'A' 원자력발전소 대체교류 디젤발전기건물에 대한 화재위험도분석을 수행하였다. 분석결과 기술기준에 만족하게 설치되었고 안전정지에 미치는 영향이 없으나 설비운영측면에서 보완할 부분이 도출되었다. 본 논문에 적용된 분석방법, 연구결과 등은 향후 가동중 원자력발전소 신축건물 화재위험도분석시 유용하게 활용될 것으로 기대된다.

  • PDF

화재현장 연소가스 감지소자 감도성능검증 연구

  • Yu, Song-Hyeon;Choe, Mun-Su;Park, Sang-Tae;Hong, Seong-Ho;Yu, Sang-Pil
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.128-129
    • /
    • 2013
  • 화재 현장에는 소방대원의 생명에 위협이 될 수 있는 다양한 연소가스가 발생하며, 소방대원의 안전에 다양한 연소가스의 농도를 실시간으로 측정하는 것은 매우 중요하다. 현재 무선통신 기술의 발달과 센서 기술의 발전으로 저전력, 소형의 센서를 이용하여 무선으로 화재현장의 온습도조건, 발생가스의 농도, 소방대원의 생체신호를 화재현장의 지휘센터로 보내주는 기술의 개발이 진행되고 있다. 이러한 추세에 맞추어 측정된 가스의 농도를 실시간으로 지휘센터로 송수신하는 기술의 연구가 활발히 진행 중이다. 본 연구는 화재환경에서 주로 발생되는 CO, NO2, NH3를 위주로한 고온의 환경에서 농도를 측정하기 위한 방법에 대한 연구이다.

  • PDF

Development of Firefighting Performance Test Drills while Wearing Personal Protective Equipment (소방방화복을 착용했을 때의 소방진압 업무 적합도 평가 프로토콜의 개발)

  • Kim, Siyeon;Lee, Joo-Young
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.138-148
    • /
    • 2016
  • A firefighting simulation was developed in order to assess the physical work capacity of firefighters. The simulation consisted of eight common firefighting tasks, including walking with radiant heat for 3 min while wearing full personal protective equipment (PPE). Nine professional firefighters performed the test a total of three times with a 5 min rest interval between each session. The entire series of tests took approximately 30 min to complete ($381{\pm}30s$). Rectal temperatures were found to increase from $37.4{\pm}0.3^{\circ}C$ to $38.5{\pm}0.4^{\circ}C$, while heart rates were found to increase from $92{\pm}18bpm$ to $185{\pm}13bpm$ during testing. Time to completion of the test drills and non-modified physical fitness values showed a significantly negative correlation (r = -0.728, p < 0.05). Firefighters who had longer periods of firefighting service had longer duration time and also recorded higher scores using an integrated scoring system of time to completion (TTC) and physiological strain index (PhSI). The results indicated that the determination of TTC alone can be a misrepresentation of capability, as it neglects to account for accumulated heat strain. The simulated firefighting test provided a useful insight into physical fitness level, but also the comprehensive work capacity of the firefighters when assessed based on TTC and PhSI.