고온 원관형 히트파이프의 열전달 특성에 관한 실험 연구 (An Experimental Study on the Heat Transfer Characteristics of High-Temperature Cylindrical Heat Pipes)

  • 박수용;부준홍
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.70-76
    • /
    • 2004
  • High-temperature cylindrical sodium/stainless-steel heat pipes were manufactured and tested for transient as well as steady states. Total length of the heat pipe was 1 m and the diameter was 25.4 mm. Screen meshes of 3 different sizes were used to estimate the effect of mesh size on the thermal performance of the heat pipe. The minimum thermal resistance achieved was as low as 0.02$^{\circ}C$/W for the maximum thormal load of 2 ㎾. The average heat transfer coefficient in the evaporator was about 2,000 ㎾/$m^2$K and those in the condenser region were up to 5 times higher.

VTM 정광 염배소 산물에 대한 바나듐 수침출 거동 분석 및 고농도 바나듐 용액 제조 (The Water Leaching Behavior of Vanadium from a Salt-roasted VTM Concentrate and the Preparation of High-concentration Vanadium Solution)

  • 박유진;김리나;김민석;전호석;정경우
    • 자원리싸이클링
    • /
    • 제31권2호
    • /
    • pp.56-62
    • /
    • 2022
  • 본 연구에서는 탄산나트륨(Na2CO3)을 사용하여 염배소한 함바나듐 티탄철광(VTM)으로부터 바나듐의 수침출 거동을 고찰하였다. 자력선별 된 정광과 Na2CO3를 질량비 4:1로 혼합한 후 1050 ℃, 3시간 조건에서 염배소하고 로드밀을 사용해 D50=48.79 ㎛로 분쇄하여 연구에 사용하였으며 침출 온도와 광액 농도를 수침출 영향인자로 선정하였다. 연구 결과, 온도가 25, 55, 85 ℃로 증가할수록 바나듐의 침출율은 90.4, 88.2, 83.8%로 감소하였으며 광액 농도 10, 50, 100 w/v%에 따른 바나듐 침출율은 각각 90.4, 87.0, 87.0%로 변화가 크지 않았다. 이를 바탕으로 25 ℃, 100 w/v%, 300 rpm, 1시간의 조건에서 다단 침출을 수행한 결과, 총 4단 침출 후 최종 침출액의 바나듐 농도는 16.20 g/L로 분석되었다. 따라서 다단 침출을 통해 고농도 소듐바나데이트 용액의 제조가 가능하였다.