• Title/Summary/Keyword: 소구치

Search Result 605, Processing Time 0.027 seconds

THE STUDY OF COMPARISON BEFORE AND AFTER ORTHODONTIC TREATMENT IN CLASS I BIALVEOLAR PROTRUSION CASES WITH FOUR BICUSPID EXTRACTION (제 1 소구치 발치를 동반한 제 I 급 치조성 양악 전돌 환자의 치료 전${\cdot}$후 비교에 관한 연구)

  • Kim, Hyung-Don;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.24 no.1 s.44
    • /
    • pp.149-159
    • /
    • 1994
  • The purposes of present study were to evaluate changes in models and lateral cephalometric head films during orthodontic treatment and to compare the amount of incisal retraction and anterior movement of molars with the two approaches of the retraction method of canine(sectional canine retractions vs sliding canine retractions) and the anchorage management(head gears vs no head gears, transpalatal arches vs no transpalatal arches and lingual arches vs no lingual arches) and to evaluate changes during orthodontic treatment in models with relation to lateral cephalometric head films. 67 Korean women with Angle's Class I bialveolar protrusion were selected, whose initial chronologic age was above 16 yrs. Models and lateral cephalometric head films were taken before and after orthodontic treatment with four bicuspid extraction. the results were obtained as follows. 1. Significant decreases were observed in intermolar width, arch length and arch perimeter of maxilla and mandible but significant difference was not observed in intercanine width of maxilla and mandible during treatment period. 2. The linear change of the upper incisor to upper lip was 2.84:1 and the linear change of the lower incisor to lower lip was 1.45:1 3. There were no significant differences between the two groups(sectional canine retractions vs sliding canine retractions), the !we groups(transpalatal arches vs no transpalatal arches) and the two groups(lingual arches vs no lingual arches) in the amount of incisal retraction and anterior movement of molars. There were a greater amount of maxillary incisal retraction and a lesser amount of anterior movement of maxillary molars with the use of head gears than no use of head gears. 4. Changes during orthodontic treatment in models with relation to lateral cephalometric head films were obtained as follows : 1) Maxilla Central incisors were moved 3.79mm backward, canines were moved 0.22mm laterally and 3.70mm backward, and molars were moved 0.535mm medially and 2.29mm forward. 2) Mandible Central incisors were moved 3.04mm backward, canines were moved 0.145mm laterally and 3.92mm backward, and molars were moved 0.755mm medially and 1.77mm forward.

  • PDF

A STUDY ON THE SHEAR BOND STRENGTH OF LIGHT-CURED GLASS IONOMER CEMENT (광중합형 글래스아이오노머 시멘트의 전단결합강도에 대한 연구)

  • Kim, Hyun-Yang;Tae, Ki-Chul;Kook, Yoon-Ah;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.689-698
    • /
    • 1998
  • The purpose of this study was to evaluate the shear bond strength of light cured glass ionomer cement to enamel surface which treated with $37\%$ phosphoric acid, $10\%$ polyacrylic acid, $1.23\%$ acidulated phosphate fluoride gel and no etching agent. To compare the shear bond strength of glass ionomer cement, light-cured composite resin and chemically-cured composite resin were empoloyed as controls. Eight experiments groups were composed. 10 specimens of each group were bonded by metal bracket by tested in universal testing machine for shear bond strength, in stereoscope for adhesive remnants index. The data were evaluated statistically by SPSS/PC+. The results were as follows. 1. Among the groups of $37\%$ phosphoric acid treated and dry and bonded with light cured glass ionomer, light cured composite resin, and chemically cured composite resin, the shear bond strength of glass ionomer group showed no significant difference to the others, but the shear bond strength of chemically cured resin showed statistically lower than that of light cured resin (p<0.05). 2. The shear bond strengths of glass ionomer cement to enamel treated group with $1.23\%$ acidulated phosphate fluoride gel and $10\%$ polyacrylic acid and $37\%$ phosphoric acid showed statistically higher than that of no etched enamel group(p<0.U). 3. In the groups of glass ionomer cement, the presence of moisture was not significantly effect to the shear bond strength (p<0.05). 4. After debonding, no etched enamel group showed less residual materials on the enamel surface than the group of enamel etched with $37\%$ Phosphoric acid.

  • PDF

A Change of Shear Bond Strength of Orthodontic Resin Adhesives under Water Immersion (침수후 시간에 따른 교정용 레진접착제의 전단결합강도 변화)

  • Lee, Je-Jun;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.783-789
    • /
    • 1998
  • The purpose of this study was to evaluate the changes of shear bond strengths and failure patterns in orthodontic resin adhesives according to the water immersion time. Metal brackets were bonded to the specimens involving the premolars with chemical-cured($Concise^{\circledR}$) and light-cured($Transbond^{\circledR}$) adhesives. The shear bond strength was measured on universal testing machine and the failure patterns were assessed with the adhesive remnant index(ARI) after storage in distilled water at $37^{\circ}C$ for 1 day, 1 week and 1, 3, and 6 months, respectively. The results were as follows. 1. The shear bond strengths at the 6 month in both Concise and Transbond were significantly higher than those at the 1 day, 1 week and 1 month(p<0.05). There were positive correlations between shear bond strength and water immersion time in both Concise and Transbond(P<0.01). 2. There were no significant differences in shear bond strength between Concise and Transbond. 3. The brackets were failed primarily at the bracket base-adhesive interface and there was no significant difference in the incidence of ARI scores according to the water immersion time.

  • PDF

The shear bond strength and adhesive failure pattern in bracket bonding with different light-curing methods (브라켓 접착시 광중합방식에 따른 전단결합강도와 파절양상 비교)

  • Shin, Jai-Ho;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.34 no.4 s.105
    • /
    • pp.333-342
    • /
    • 2004
  • The purpose of this study was to evaluate the clinical effectiveness of a plasma arc light and light emitting diode (LED), compared with shear bond strength and the failure pattern of brackets bonded with visible light in direct bonding. Brackets were bonded with Transbond XT to 60 human premolars embedded in the resin blocks according to different light-curing methods. Then, the shear bond strength of each group was measured using a universal testing machine (Instron) and the adhesive failure pattern after debonding was visually examined by light microscope. The results were as follows: 1. The shear bond strength showed no significant difference between the visible light and light emitting diode, but the plasma arc light exhibited a significantly lower shear bond strength compared with the visible light and light emitting diode. 2. In the visible light and light emitting diode, adhesive failure patterns were similar. Bond failure occurred more frequently at the enamel-adhesive interface. 3. The bonding failure of brackets bonded with plasma arc light occurred more frequently at the bracket-adhesive interface. The results of this study suggest that plasma arc light, light emitting diode and visible light are all clinically useful in the direct bonding of orthodontic brackets.

Effects of compressive stress on the expression of M-CSF, IL-$1{\beta}$, RANKL and OPG mRNA in periodontal ligament cells (압박력이 치주인대 세포의 M-CSF, IL-$1{\beta}$, RANKL 및 OPG mRNA 발현에 미치는 영향)

  • Kim, Ji-Woong;Lee, Ki-Soo;Nahm, Jong-Hyun;Kang, Yoon-Goo
    • The korean journal of orthodontics
    • /
    • v.39 no.4
    • /
    • pp.248-256
    • /
    • 2009
  • Objective: The aim of this study was to determine if human PDL cells can produce osteoclastogenic mRNA and examine how compressive stress affects the expression of osteoclastogenic mRNA in human PDL cells. Methods: Human PDL cells were obtained from biscupids extracted for orthodontic treatment. The compressive force was adjusted by increasing the number of cover glasses. PDL cells were subjected to a compressive force of 0.5, 1.0, 2.0, 3.0 or $4.0\;g/cm^2$ for 0.5, 1.5, 6, 24 or 48 hours. Reverse transcription polymerase chain reaction (RT-PCR) analysis was performed to examine levels of M-CSF, IL-$1{\beta}$, RANKL, OPG mRNA expression. Results: Human PDL cells could produce M-CSF mRNA. Human PDL cells under compressive stress showed increased M-CSF, IL-$1{\beta}$ and RANKL mRNAs expression in a force (up to $2\;g/cm^2$) and time-dependent manner. However, OPG mRNA expression was constant regardless of the level and duration of stress. Conclusions: Continuous compressive stress induced the mRNA expression of osteoclastogenic cytokines including M-CSF, RANKL, IL-$1{\beta}$ in PDL cells. Together with an unchanged OPG mRNA level, these results suggest that compressive stress-induced osteoclastogenesis in vivo is partly controlled by M-CSF, RANKL and IL-$1{\beta}$ expression in PDL cells.

A Study on the Enamel Surface Texture and Caries Susceptibility in Interdentally Stripped Teeth (치간삭제 후의 법랑질 표면조도와 치아우식 감수성에 관한 연구)

  • Kim, Kyong-Nim;Yoon, Young-Ju;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.31 no.6 s.89
    • /
    • pp.567-578
    • /
    • 2001
  • To investigate the difference of Texture exhibited on interproximal enamel surface with each different stripping method and the susceptibility of proximal enamel to demineralization after stripping and the application of a topical fluoride go] and sealant, one hundred human premolars, which were Previously extracted for orthodontic reasons were evaluated by means of Scanning electron microscopy and laser fluorescence. The results were as follows : 1. No matter what the initial stripping instrument was the furrows that resulted from all the stripping methods were not completely removed by careful polishing. 2. Among the enamel surfaces that were treated with three different initial abrasive instruments, followed by the same polishing method (Sof-$Lex^{(r)}$ disks), the enamel surfaces that were treated with 700 crosscut carbide bur showed the smoothest surfaces. 3. The stripped teeth, no matter what the initial stripping instrument was, were less resistant to initial demineralization than untreated teeth. But no difference in caries susceptibility according to differently stripped methods was found (p<(0.001). 4. Teeth treated with APF-gel or sealant were mote resistant to demineralization than those treated without other treatment after stripping (p<0.001). 5. Comparing groups treated with APF-gel to groups treated with sealant, the former was more resistant to demineralization than the tatter (p<0.05). In conclusion, enamel surfaces that were stripped jnterproximally were less resistant to demineralization even though various attempts were made to produce smooth, self-cleaning enamel surfaces. Therefore, additional treatment-sealant or calcifying/ fluoridating solution To the stripped enamel surfaces is recommended.

  • PDF

A three-dimensional finite element analysis of obturator prosthesis for edentulous maxilla (무치악 구개결손 환자를 위한 폐쇄장치의 삼차원 유한요소 분석)

  • Song, Woo-Seok;Kim, Myung-Joo;Lim, Young-Jun;Kwon, Ho-Beom
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.222-228
    • /
    • 2011
  • Purpose: The purposes of this study were to evaluate the stress distributions and the displacements of obturator for edentulous maxillectomy patients and to compare them with those of complete denture using three-dimensional finite element analysis. Materials and methods: Based on the CT image of edentulous patient, three-dimensional finite element model of edentulous maxillae was constructed. Three-dimensional finite element model of edentulous maxillae with palatal defect was also fabricated. On each model, complete denture and obturator prosthesis were created. Vertical static force of 200 N was applied on the left maxillary premolar and molar region. The von Mises stress values and the displacements of models were analyzed using three-dimensional finite element analysis. Results: Maximum von Mises stress values were recorded in the cortical bones of both models. The von Mises stress value in the complete denture model was 2.73 MPa and 2.69 MPa in the obturator model. High von Mises stress values were also observed on the tissue surface of prosthesis. The maximum value of the displacement in the obturator was higher than that of complete denture. Conclusion: The obturator showed a worse result in terms of stress distribution and displacement than complete denture. In the prosthodontic rehabilitation of edentulous maxillectomy patient accurate impression procedure based on patients'anatomy and application of prosthodontic principle should be considered.

Clinical evaluation of a new extraction method for intentional replantation (의도적 재식술을 위한 새로운 발치법의 임상 평가)

  • Choi, Yong-Hoon;Bae, Ji-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.3
    • /
    • pp.211-218
    • /
    • 2011
  • Purpose: Intentional replantation (IR) is a suitable treatment option when nonsurgical retreatment and periradicular surgery are unfeasible. For successful IR, fracture-free safe extraction is crucial step. Recently, a new extraction method of atraumatic safe extraction (ASE) for IR has been introduced. Patients and Methods: Ninety-six patients with the following conditions who underwent IR at the Department of Conservative Dentistry, Seoul National University Bundang Hospital, in 2010 were enrolled in this study: failed nonsurgical retreatment and periradicular surgery not recommended because of anatomical limitations or when rejected by the patient. Preoperative orthodontic extrusive force was applied for 2-3 weeks to increase mobility and periodontal ligament volume. A Physics Forceps was used for extraction and the success rate of ASE was assessed. Results: Ninety-six premolars and molars were treated by IR. The complete success rate (no crown and root fracture) was 93% (n = 89); the limited success rates because of partial root tip fracture and partial osteotomy were 2% (n = 2) and 5% (n = 5), respectively. The clinical and overall success rates of ASE were 95% and 100%, respectively; no failure was observed. Conclusions: ASE can be regarded as a reproducible, predictable method of extraction for IR.

Severe bidentoalveolar protrusion treated with lingual Biocreative therapy using palatal miniplate (구개측 미니플래이트를 이용한 양악 치아치조성 전돌환자에서의 설측 Biocreative therapy 적용)

  • Chung, Kyu-Rhim;Jeong, Do-Min;Park, Hyun-Jung;Kim, Seong-Hun;Nelson, Gerald
    • The korean journal of orthodontics
    • /
    • v.40 no.4
    • /
    • pp.276-287
    • /
    • 2010
  • This case report describes the treatment of a 23-year, 8-month-old female patient with a Class II malocclusion who showed severe bidentoalveolar protrusion and anterior crowding. The treatment plan consisted of extracting all the first premolars, decrowding and en masse retraction of the upper six anterior teeth and lower anteriors. The upper C-plate placed in the midpalatal area combined with lingual sheath fixtures were used as substitutes for posterior anchorage teeth during upper anterior retraction. Preadjusted brackets (0.022-inch) were used for upper anterior decrowding. A 0.9 mm diameter stainless steel lever-arm soldered to the main arch wire facilitated controlled retraction of upper anteriors. The upper and lower dentition was detailed using a tooth positioner during the finishing stage. Correct overbite and overjet were obtained by decrowding and retraction of the upper six anterior teeth into their proper positions. Use of the C-plate and lingual appliances provided ideal anchorage to enhance the improvement in facial balance. The active treatment period was 19 months. The treatment result was stable 13 months after debonding.

COMPARISON OF BOND STRENGTH OF A FIBER POST CEMENTED WITH VARIOUS RESIN CEMENTS (다양한 레진시멘트로 합착한 섬유포스트의 결합강도 비교)

  • Lee, Hyun-A;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.6
    • /
    • pp.499-506
    • /
    • 2008
  • The purpose of this study was to compare the push-out strength of a fiber post cemented with various resin cements. Newly extracted 36 human mandibular premolars which had single root canal were selected and their crown portions were removed. The root canal was instrumented using $PROTAPER^{TM}$ system and obturated using continuous wave technique. In each root, a 9-mm deep post space was prepared. #2 translucent fiber post (DT Light post, Bisco Inc., Schaumburg, IL, U.S.A.) was cemented using injection technique with Uni-dose needle tip (Bisco) and six different resin cements. The tested resin cements were Duo-Link (Bisco Inc., Schaumburg, IL, U.S.A.), Variolink II (Ivoclar-Vivadent AG, Schann, Liechtenstein), Panavia F (Kuraray Medical Inc., Okayama, Japan), Multilink Automix (Ivoclar-Vivadent AG, Schann, Liechtenstein), RelyX Unicem (3M ESPE Dental Products, St. Paul, MN, U.S.A.), and Maxcem (Kerr Co., CA, U.S.A.). After storage in distilled water for 24 hours, each root was transversally sectioned into approximately 1-mm thick sections. This procedure resulted in 6 serial sections per root. Push-out test wasperformed using a universal testing machine (EZ Test, Shimadzu Co.) with a crosshead speed of 1 mm/min. The data were analyzed with one-way ANOVA and Tukey HSD (p=0.05). The push-out strength of the groups which cemented fiber post with Panavia F and Multilink Automix were lower than those of the other groups. But, there were no statistically significant difference among groups at a probability level of 0.05.