A Study on the Manufacturing Technology of Heat Pipes with a Sintered Metal Wick (소형 소결웍 히트파이프의 제조 기술개발에 관한 연구)

  • 김성대;성병호;강환국;김철주
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.11a
    • /
    • pp.291-297
    • /
    • 2003
  • For the present study, three heat pipes with different thickness of sintered metal wick were manufactured, and their operational performances, such as capillary limit and thermal resistance were tested and compared with theoretical predictions. Experimental results showed good agreement with those by the theoretical model, and that seemed to present that the sintering process we had developed ;n the present study was valid.

  • PDF

Comparison of the Heat transport Limitations for Screen Mesh Wick and Sintered Metal Wick Heat Pipes by Theoretical Analysis (이론적 해석에 의한 스크린 메쉬윅과 소결윅 히트파이프의 열수송 한계 비교)

  • Kim Keun-Bae;Kim Yoo
    • Journal of Energy Engineering
    • /
    • v.13 no.4
    • /
    • pp.267-274
    • /
    • 2004
  • Theoretical analysis for predicting the heat transport limitations of screen mesh wick and sintered wick heat pipes was performed. The heat pipe diameter was 8mm and water was used for working fluid. For the 250 mesh, each capillary pressures and heat transport limitations, thermal resistances were analyzed according to the operating temperatures, wick thicknesses and inclination angles, based on the effective capillary radius (r$\_$c/), porosity ($\varepsilon$) and permeability (K). The wick capillary limitation was increased as the operating temperature and the wick thickness were increased, and generally the sintered wick showed higher heat transport limitations than that of the screen wick. The thermal resistance of the screen wick was higher than that of the sintered wick and both thermal resistances were linearly increased as the wick thickness was increased.

A study on the characteristics of a frozen start up for a variable conductance heat pipe (가변전열 히트파이프의 저온 시동특성에 관한 연구)

  • Hong, Sung-Eun;Kang, Hwan-Kook;Cho, Kwang-Cheal
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.339-345
    • /
    • 2006
  • This these was conducted to investigate tile characteristics of a frozen start up for a VCHP which has water as a working fluid and Nitrogen as a non-condensible gas. The tested heat pipe was made of a copper tube with the outer diameter of 12.7 mm, the length of 340 mm, and the sintered metal wick had the thickness of 0.7 mm. This experiment was conflicted under the thermal load, inclined angle and cooling conditions.

  • PDF

The PALM system : Architecture and Network Performance (PALM시스템의 구조와 네트웍 성능)

  • Kim, Suk-Il
    • The Transactions of the Korea Information Processing Society
    • /
    • v.1 no.1
    • /
    • pp.105-113
    • /
    • 1994
  • This paper introduces the Parallel Advanced Loosely coupled Multiprocessor (PALM) architecture, which is based on HCH(m,p), where m is number of links per a communication processor (CP) and p is the number of application processors (APs) connected to the CP. communication links between a pair of CPs and/or between a CP and an AP, are made of dual-Port RAMs, which provide fast and reliable word-parallel communication between processors. Among the wide spectrum of HCH networks, HCH(m,2) is also known to be a cost optimal topology, such that HCH(m,2) consists of the largest number of APs retaining the minimal number of CPs and communication links. We also implement a testbed based on HCH(2,2). The experiment result shows that the small communication/computation ratio of the PALM system would realize fine-grain parallelism on message-passing MIMD systems.