• Title/Summary/Keyword: 세정수

Search Result 676, Processing Time 0.032 seconds

Hydraulic Cleaning Effect on Fouling Mechanisms in Pressurized Membrane Water Treatment (가압식 멤브레인 수처리에서 수리학적 세정이 파울링 기작에 미치는 영향)

  • Charfi, Amine;Jang, Hoseok;Kim, Jeonghwan
    • Membrane Journal
    • /
    • v.27 no.6
    • /
    • pp.519-527
    • /
    • 2017
  • Membrane fouling is the main issue hindering the expansion of low pressure membrane processes for surface water treatment. Therefore, applying periodic hydraulic cleaning for fouling control should be well optimized. Better understanding of membrane fouling associated with periodic hydraulic cleaning would be useful to optimize membrane cleaning strategies. By comparing experimental permeability data with the classical Hermia blocking laws, this study aims at analyzing membrane fouling and understanding dominant fouling mechanisms occurring when filtering a synthetic surface water solution with a pressurized membrane process during six filtration cycles of 30 min each, separated with cyclic cleaning of 1 min by backwashing and forward flushing separately and combined. When applying single cleaning technique, membrane fouling during the first cycles was controlled by complete blocking mechanism while the last cycles were dominated by cake formation. Nevertheless, when combining cleaning technique better membrane regeneration was obtained and fouling was mainly due to cake formation.

High Temperature Application of Iron Removal Chemical Cleaning Solvent in the Secondary Side of Nuclear Steam Generators (증기발생기 2차측 제철화학세정액의 고온적용)

  • Hur, D.H.;Lee, E.H.;Chung, H.S.;Kim, U.C.
    • Nuclear Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.140-148
    • /
    • 1994
  • A qualification test was performed for the iron removal chemical cleaning of the secondary side of nuclear steam generators at the selected temperature, 1$25^{\circ}C$, higher than the standard application temperature, 93$^{\circ}C$. The field cleaning condition for a nuclear unit was tested in a bench scale test loop including a SUS 316 stainless steel autoclave with one gallon capacity as a test vessel. The kinetics of sludge dissolution, corrosion of the secondary side materials and change of solvent chemistry were monitored. Test results indicated that more thorough cleaning was accomplished in less than half of the cleaning time required at 93$^{\circ}C$. And the total corrosions of the secondary side materials were found to be less than the values at 93$^{\circ}C$. While the solvent is recirculated and heated by an external chemical cleaning equipment for the conventional 93$^{\circ}C$ process, the secondary side is heated by the lateral heat of the primary coolant without the recirculation of the cleaning solution, and the solvent is mixed by vigorous boiling induced by periodic ventilation for the high temperature process. The requirement that the reactor coolant pumps should be running during the cleaning operation is the major disadvantage of the high temperature process which also should be considered when chemical cleaning is planned for steam generators under operation.

  • PDF

Application of Super Sonic Wave Technic to Textile Industry (섬유산업에 초음파 응용기술)

  • Seo, Mal Yong;Lee, Suk Young
    • Textile Coloration and Finishing
    • /
    • v.8 no.4
    • /
    • pp.59-68
    • /
    • 1996
  • 섬유산업에 초음파의 이용은 극히 새로운 것이 아니며, 초음파를 이용하여 시간단축과 공정개선 등에 관한 많은 문헌들도 있다. 게다가 세정과 기계분야, 안정된 분산용액의 제조에 두드러지게 활용되고 있는 기술이며, 다른 새로운 분야로도 연구확대되고 있다. 주로 세정조에 구성되어 있는 초음파발생자치는 세정효율을 높이기 때문에 응용확대가 기대된다. 특별한 장치가 필요없기 때문에 음화학반응에서 관심이 모아지고 있다. 초음파는 이제 광범위한 습식공정에 영향을 미치는 기술로 이해되고 있다. 이 자료는 이미 연구된 결과를 재조명하고 초음파를 이용하므로서 얻을 수 있는 이점에 대해서 어떤 것이 있는지에 대해 살펴보고자 한다.

  • PDF

Via Cleaning Process for Laser TSV process (Laser TSV 공정에 있어서 Via 세정에 관한 연구)

  • Seo, Won;Park, Jae-Hyun;Lee, Ji-Young;Cho, Min-Kyo;Kim, Gu-Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.1
    • /
    • pp.45-50
    • /
    • 2009
  • By Laser Through-Silicon-Via process, debris and particles occur when you are forming. Therefore the research of TSV cleaning become important to remove those particles and debris. Both chemical cleaning method that uses a surfactant and physical cleaning method that uses a brush were studied with the via of $30{\mu}m$ diameter and $100{\mu}m$ depth on the 8 inch CMOS Image Sensor wafer. On the DI water and a surfactant in mixture ratio of 2:1, debris show $73{\mu}m^2$ per $0.054mm^2$. Cleaning is superior by lower mixture ratio of DI water and surfactant. In addition, It is less than 5% of debris distribution in the laser condition changed by Laser's frequency and its speed and cleaning had no effect. In the physical cleaning, there are no crack and damage when the system condition is set by $1000{\sim}3000rpm$ strip, $50{\sim}3000rpm$ rinsing, and $200{\sim}300rpm$ brushing Therefore, debris and particles can be removed by enforced chemical method and physical method.

  • PDF

Improvement of Fouling in Membrane Separation Process for Leachate Treatment using Ultrasound(I) : Analysis of Ultrasonic Parameters (초음파를 이용한 침출수 처리를 위한 막분리 공정의 막힘현상 개선(I) : 초음파의 영향인자 평가)

  • Kim, Seok-Wan;Lim, Jae-Lim;Lee, Jun-Geol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.2
    • /
    • pp.197-206
    • /
    • 2006
  • This study evaluated the effect of ultrasonic irradiation on improving the flux and cleaning efficiency in membrane process which is widely applied for the treatment of landfill leachate. The experiments on improvement of membrane flux according to the types of membranes(hallowfiber microfiltration, MF and tubular ultrafiltration, UF) were performed with changing frequency($40{\sim}120$ kHz), intensity ($200{\sim}500$ W) and irradiation time of ultrasound as well us operation pressure($0.1{\sim}2.3kg/cm^2$). Membrane was fouled for the first 50 min with primary treated leachate and then the change in flux according to ultrasonic irradiation period was observed for 70 min. Parameters influenced to the recovery ratio corresponding the net flux on pure water and to the enhancement ratio applied after ultrasonic irradiation on the flux were analyzed. In same condition, the flux was improved in proportion to ultrasonic intensity while the improvement of flux was inversely proportional to ultrasonic frequency. The cleaning effect of membrane was delayed and reduced when operation pressure of membrane was high. The recovery ratio and enhancement ratio for $0.1{\mu}m$ MF membrane were 10% and 500%, respectively while those were maximized at $75{\sim}98%\;and\;40{\sim}50%$ for UF membrane for 10,000 and 100,000 MWCO, respectively. In conclusion, it was confirmed that ultrasonic cleaning using mechanical vibration is alternative to water or chemical cleaning for improving membrane flux.

Recycling Technique of Nano TiO2-Coated Silica-bead (나노광촉매가 코팅된 실리카 비드의 재생 연구)

  • Do, Young-Woong;Ha, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3269-3273
    • /
    • 2009
  • In this study, recycling methods of nano $TiO_2$-coated silica-bead were conducted in order to solve a deactivation problem of bead that had been invented for decomposition of pollutants in aqueous solution. Surface cleansing was selected as the recycling method for used beads. The surface cleansing was done with four different solutions such as distilled water, surfactant, acetone, and ethyl alcohol(ethanol). The recycling process consists of cleansing and calcination. After cleaning the used (deactivated) beads, calcination was done at $100^{\circ}C$, $200^{\circ}C$ and $300^{\circ}C$ for 30 minutes, respectively. This process was repeated three times. The activity of the recycled bead was measured by photo-degradation of methylene blue. The result shows that acetone cleansing and calcination at $100^{\circ}C$ for 30 minutes was the most efficient recycling method.

A Technicial Patent Study on Recycled Water of Face Washing in Toilet Seat (양변기의 세면수 재활용에 대한 기술적 특허 고찰)

  • Lim, Sang-Ho;Choi, Byung-Joo;Kim, Seok-Gwon
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.735-738
    • /
    • 2009
  • 본 연구분석은 세면대에서 사용한 세면수를 화장실 변기의 세정수로 재활용 할 수 있도록 하는 절수식 일체형 세면대와 양변기 기술에 대한 특허분석으로, 국내외의 특허 동향을 파악하고자 함과 관련사의 기술동향 및 핵심특허 분석을 통하여 연구개발 방향을 설정 점검하고, 기술추이 및 사업성 검토, 연구개발 예산의 효율적 기초자료로 활용하고자 함이다.

  • PDF

UF Separation of the Waste Water Containing Silicon Fine Particle (Si 미립자 함유 폐수의 UF 투과 특성)

  • 이석기;김우정;전재홍;곽순철;남석태;최호상
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.129-130
    • /
    • 1997
  • 1. 서론 : 반도체 제조공정중 wafer가공 공정에 사용되는 많은 양의 RO 초순수는 미세한 규소입자를 비롯하여 비교적 낮은 농도의 불순물을 포함하고 있으나, 현재 1차세정후 공정폐수로 전량 희석되어 폐기되고 있다. 반도체 제조공정에서 발생되는 이러한 세정폐수를 적절한 전처리와 분리막 처리를 통하여 유가물질인 Si 입자를 회수하고, 처리수를 재이용함으로써 환경오염의 감소 및 공업용수의 증대를 도모할 수 있다. 본 연구에서는 고분자 분리막을 이용하여 반도체 제조공정중 발생한 세정중의 유가물질인 Si를 회수하고, 용수를 재이용하기 위하여 한외여과용 평막을 제조하여 Si 함유 폐수에 대한 막성능을 평가하였으며, 또한 상용 tubular 및 hallow fiber막의 성능과도 비교하였다.

  • PDF

Steam Generator Chemical Cleaning (특집_제25회 한국원자력연차대회 - 증기발생기 화학 세정)

  • D'Annucci, Filippo;Mutius, Bernard
    • Nuclear industry
    • /
    • v.30 no.3
    • /
    • pp.52-56
    • /
    • 2010
  • 증기발생기 2차측 상태는 발전소 운영에 있어 중요한 역할을 수행한다. 기기, 배관 및 열교환기에서 발생되는 침적물은 증기발생기 튜브의 부식 원인이 될 수 있으며, 튜브와 튜브 지지판 사이의 공간을 차단한다. 2차측 침적물에 의한 튜브 파손으로 인해 일부 발전소에서는 강제적으로 발전을 정지하는 사례가 발생하였다. 또한 튜브 지지판의 침적물 축적으로 인해 정상 운전 동안 전력 생산을 감소하게 되는 결과를 초래한 발전소도 있었다. 따라서 증기발생기 2차측 상태 감시와 더불어 증기발생기 부품의 청결 유지는 필수 항목이라 할 수 있다. 웨스팅하우스에서는 증기발생기를 초기 제작 상태로 복구하고 2차측 침적물을 제거하기 위해 EPRI SGOG 증기발생기 화학 세정을 수 년간 이용하고 있다. 본고는 35개 이상의 발전소에서 성공적으로 이용하고 있는 화학 세정 프로세스 개요 및 프로세스를 적용하면서 취득한 경험을 요약한 것이다.

  • PDF

전기부상법을 이용한 토양세정 유출수 중 유수분리에 관한 연구 : 전해질에 의한 영향

  • 소정현;최상일;조장환;한상근;류두현
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.463-465
    • /
    • 2003
  • 전기분해에 의한 부상현상을 이용하여 유류로 오염된 토양 세정 후 발생되는 유출수 중 유분 등을 분리하기 위한 적정 운전조건을 찾고자 하였다. 전기분해 반응조(200 $\times$ 10 $\times$15cm)에 혼합 계면활성제 (POE5 : POE14, 1:1) 1% 용액에 디젤을 1,000mg/L 농도로 용해시켜 실험하였다. 양극에는 티나늄 코팅전극, 음극으로는 스테인레스 스틸전극을 이용하였다. 반응시간은 62분( 반응: 60분, 부상시간: 2분) 이었으며 전압은 6V였다. 전해질 첨가에 의한 영향을 알아보기 위하여 실험한 결과, 전해질을 첨가하였을 경우 첨가하지 않았을 때보다 40% 정도의 효율이 증가하였다. 적정 전해질, 주입농도 및 반응시간을 알아보기 위하여 1N NaCl과 NaOH의 농도를 변화시켜 가면서 실험하였다. NaCl의 경우 더 좋은 효율을 나타내었다. 전해질의 농도는 0.2 - 1.0% 의 농도 범위에서 NaCl와 NaOH 모두 농도에 따라 순차적으로 효율이 증가하였다. 두 전해질 모두 0.4 - 1.0% 농도 범위에서 평형에 도달하는 시간은 20분으로 나타났다.

  • PDF