• Title/Summary/Keyword: 세기조절 방사선 치료

Search Result 154, Processing Time 0.02 seconds

A Study on the Incidence of Side Effects according to the Number of Beams in Intensity-modulated Radiation Therapy for Prostate Cancer using 15 MV (15 MV를 이용한 전립샘암 세기조절 방사선치료 시 빔의 개수에 따른 부작용 발생률에 관한 연구)

  • Joo-Ah Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.481-487
    • /
    • 2023
  • In this study, we analyzed the incidence of side effects of photoneutron dose according to the number of beams during intensity-modulated radiotherapy of prostate cancer using 15 MV. The radiation treatment plan design for intensity-modulated radiation therapy for prostate cancer was established with a prescription dose of 220 cGy per dose and a total of 7260 cGy for 33 treatments. The linear accelerator used in the experiment is Varian's True Beam STx (Varian, USA). Photoneutron dose was generated by using 15 MV energy in the planning target volume (PTV). The treatment plan was designed with IMRT 5, 7, and 9 portals using the Eclipse System (Varian Ver 10.0, USA). An optically stimulated luminescence albedo neutron dosimeter (Landauer Inc., USA) was used to measure photoneutron dose. IMRT 5 portals, 1.7 per 1,000, 7 portals, 1.8 per 1,000, 9 portals, 2.0 per 1,000 were calculated as the probability of experiencing side effects on the thyroid gland due to photoneutron dose. This study studies the risk of secondary radiation exposure dose that can occur during intensity-modulated radiation therapy, and it is considered that it will be used as useful data in relation to stochastic effects in the future.

Comparison of Intensity-modulated Radiation Therapy (IMRT), Uniform Scanning Proton Therapy (USPT), and Intensity-modulated Proton Therapy (IMPT) for Prostate Cancer: A Treatment Planning Study (전립선 암 환자의 IMRT, USPT, 및 IMPT 기법에 따른 치료효과 비교)

  • Son, Kihong;Cho, Seungryong;Kim, Jin Sung;Han, Youngyih;Ju, Sang Gyu;Ahn, Sung Hwan;Shin, Eunhyuk;Shin, Jung Suk;Park, Won;Pyo, Hongryul;Choi, Doo Ho
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.154-161
    • /
    • 2013
  • This study assessed compared photon and proton treatment techniques, such as intensity modulated radiation therapy (IMRT), uniform scanning proton therapy (USPT), and intensity modulated proton therapy (IMPT), for a total of 10 prostate cancers. All treatment plans delivered 70 Gy to 95% of the planned target volume in 28 fractions. IMRT plans had 7 fields for the step and shoot technique, while USPT and IMPT plans employed two equally weighted, parallel-opposed lateral fields to deliver the prescribed dose to the planned target. Inverse planning was then incorporated to optimize IMPT. The homogeneity index (HI) and conformity index (CI) for the target and the normal tissue complication probability (NTCP) for organ at risk (OAR) were calculated. Although the mean HI and CI for target were not significantly different for each treatment techniques, the NTCP of the rectum was 2.233, 3.326, and 1.707 for IMRT, USPT, and IMPT, respectively. The NTCP of the bladder was 0.008, 0.003, and 0.002 respectively. The NTCP values at the rectum and bladder were significantly lower using IMPT. Our study shows that using proton therapy, particularly IMPT, to treat prostate cancer could be beneficial compared to 7-field IMRT with similar target coverage. Given these results, radiotherapy using protons, particularly optimized IMPT, is a worthwhile treatment option for prostate cancer.

Study of Energy Dependency in Intensity Modulated Radiation Therapy of Brain Tumor (세기조절방사선치료를 이용한 뇌종양에서 에너지 의존성에 관한 연구)

  • 김성규
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.104-108
    • /
    • 2002
  • As intensity modulated radiation therapy compared with conventional radiation therapy, tumor target dose increased and normal tissues and critical organs dose reduced. In brain tumor, treatment planning of intensity modulated radiation therapy was practiced in 4MV, 6MV, 15MV X-ray energy. In these X-ray energy, was considered the dose distribution and dose volume histogram. As 4MV X-ray compared with 6MV and 15MV, maximum dose of right optic-nerve increased 10.1%, 8.4%. Right eye increased 5.2%, 2.7%. And left optic-nerve, left eye, optic chiasm and brainstem increased 1.7% - 5.2%. Even though maximum dose of PTV and these critical organs show different from 1.7% - 10.1% according to X-ray energies, these are a piont dose. Therefore in brain tumor, treatment planning of intensity modulated radiation therapy in 9 treatment field showed no relation with energy dependency.

  • PDF

Evaluation of Cancer Incidence Rate using Exposure Dose to Surrounding Normal Organs during Radiation Therapy for Prostate Cancer (전립선암의 방사선 치료 시 주변 정상장기 피폭선량을 이용한 암발생확률 평가)

  • Lee, Joo-Ah
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.351-356
    • /
    • 2022
  • The purpose of this study was to evaluate the cancer incidence rate and provide basic data by measuring the photoneutron dose generated during intensity-modulated radiation therapy and volumetric modulated arc therapy used in radiation therapy for prostate cancer. The optically stimulated luminescence albedo neutron dosimeter for neutron measurement was placed on the Rando phantom in the abdomen and thyroid and photoneutron dose generated was measured. As a result of the study, intensity-modulated radiation therapy (7 portal) was measured to be higher than volumetric rotational radiation therapy in both abdominal and thyroid locations. When the cancer incidence rate was evaluated using the nominal risk coefficient of ICRP 103, the cancer incidence rate due to exposure to the colon and thyroid during intensity-modulated radiation therapy was 9.9 per 1,000 people, and volumetric rotational radiation therapy for 1,000 people. It was 3.5 per person. Based on the principle of ALARA (As low as reasonably archievable), it is considered to be a guideline for minimizing the exposure dose to normal organs in the establishment of a radiation treatment plan.

Decrease of Irradiated Volume using Rotational Treatment by Avoidance Sector in Radiation Therapy for Esophageal Cancer (식도암의 방사선치료에서 부분 각도에 의한 회전 치료를 이용한 조사체적의 감소)

  • Hwang, Chulhwan;Kim, Seong Hu;Koo, Jae Heung;Son, Jong Ki
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.583-592
    • /
    • 2018
  • In this study, plans to apply 3D conformal radiotherapy, intensity modulated radiotherapy, and volumetric intensity modulated arc radiotherapy to esophageal cancer radiotherapy were compared. In particular, arc therapy was applied to reduce irradiated volume and spread of low-dose during intensity modulated radiation therapy and volumetric intensity modulated arc radiotherapy by limiting part of irradiated angle, in order to compare target doses and dose for surrounding normal tissues of the two methods and those of 3D conformal radiotherapy. No significant difference in target dose was found among the three methods. The 5 Gy volume(V5) of the lung showed 56.53% of conformal radiotherapy, 52.03% of intensity modulated radiotherapy, and 47.84% of volumetric modulated arc therapy(CRT-IMRT p=0.035, CRT-VMAT p<0.001, IMRT-VMAT p<0.001). The 10 Gy volume(V10) showed a significant difference in conformal radiotherapy 35.12%, intensity modulated radiotherapy 34.04%, and volumetric modulated arc radiotherapy 33.28%, showing significant difference in intensity modulated radiotherapy(p=0.018), volumetric modulated arc therapy(p=0.035), no significant difference in dose was found at 20 Gy volume. The mean dose and 20 Gy volume of the heart were not significantly different according to the treatment plan, but the 30 and 40 Gy volumes were 37.16% and 22.46% in the volumetric modulated arc radiotherapy, showing significant differences(p=0.028) in comparison with conformal radiotherapy. It is believed that, by limiting part of the irradiated angle during intensity modulated radiotherapy and volumetric intensity modulated arc radiotherapy, the irradiated volume and, thereby, the 5-10 Gy area and toxicity of the lung can be reduced while maintaining dose distribution of the target dose.

Study on the Photoneutrons Produced in 15 MV Medical Linear Accelerators : Comparison of Three-Dimensional Conformal Radiotherapy and Intensity-Modulated Radiotherapy (15 MV 의료용 선형가속기에서 발생되는 광중성자의 선량 평가 - 3차원입체조형방사선치료와 세기조절방사선치료의 비교 -)

  • Yang, Oh-Nam;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.335-343
    • /
    • 2012
  • Intensity-modulated radiotherapy(IMRT) have the ability to provide better dose conformity and sparing of critical normal tissues than three-dimensional radiotherapy(3DCRT). Especially, with the benefit of health insurance in 2011, its use now increasingly in many modern radiotherapy departments. Also the use of linear accelerator with high-energy photon beams over 10 MV is increasing. As is well known, these linacs have the capacity to produce photonueutrons due to photonuclear reactions in materials with a large atomic number such as the target, flattening filters, collimators, and multi-leaf collimators(MLC). MLC-based IMRT treatments increase the monitor units and the probability of production of photoneutrons from photon-induced nuclear reactions. The purpose of this study is to quantitatively evaluate the dose of photoneutrons produced from 3DCRT and IMRT technique for Rando phantom in cervical cancer. We performed the treatment plans with 3DCRT and IMRT technique using Rando phantom for treatment of cervical cancer. An Rando phantom placed on the couch in the supine position was irradiated using 15 MV photon beams. Optically stimulated luminescence dosimeters(OSLD) were attached to 4 different locations (abdomen, chest, head and neck, eyes) and from center of field size and measured 5 times each of locations. Measured neutron dose from IMRT technique increased by 9.0, 8.6, 8.8, and 14 times than 3DCRT technique for abdomen, chest, head and neck, and eyes, respectively. When using IMRT with 15 MV photonbeams, the photoneutrons contributed a significant portion on out-of-field. It is difficult to prevent high energy photon beams to produce the phtoneutrons due to physical properties, if necessary, It is difficult to prevent high energy photon beams to produce the phtoneutrons due to physical properties, if necessary, it is need to provide the additional safe shielding on a linear accelerator and should therefore reduce the out-of-field dose.

A Study on Radiation Exposure using Nominal Risk Coefficients (명목위험계수를 활용한 방사선 피폭에 관한 연구)

  • Joo-Ah Lee;Jong-Gil Kwak;Cheol-Min Jeon
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.4
    • /
    • pp.383-389
    • /
    • 2024
  • In this study, we aimed to analyze the probability of secondary cancer occurring in the abdomen, a normal organ, due to photoneutron exposure during intensity-modulated radiotherapy for prostate cancer. The design of the radiation treatment plan for prostate cancer was established as a daily prescription dose of 220 cGy, a total of 35 treatments, and 7700 cGy. The experimental equipment was a True Beam STx (Varian, USA) linear accelerator from Varian. The energy used in the experiment was 15 MV, and the treatment plan was designed so that the photoneutron dose would be generated within the planning target volume (PTV). The radiation treatment plan was an Eclipse System (Varian Ver. 10.0, USA), and the number of irradiation portals was set to 5 to 9. The irradiation angle was designed so that 95% of the prescription dose area was set to 0 to 320°, and the number of beamlets per irradiation portal was set to 100. The optically stimulated luminescence dosimeter used in this study to measure the dose of photoneutrons was designed to measure photoneutron doses by coating 6LiCO3 on a device containing aluminum oxide components. It was studied that there is a minimum of 7.07 to 11 cases per 1,000 people with secondary cancer due to the photoneutron dose to the abdomen during intensity-modulated radiotherapy. In this study, we studied the risk of secondary radiation dose that may occur during intensity-modulated radiotherapy, and we expect that this will be used as meaningful data related to the probabilistic effects of radiation in the future.

Study of $\textrm{IMFAST}^{TM}$ Segmentation Algorithm with CORVUS TPS for Intensity Modulated Radiation Therapy (세기조절 방사선 치료에서 CORVUS TPS를 이용한 $\textrm{IMFAST}^{TM}$ Segmentation Algorithm의 연구)

  • Lee, Se-Byeong;Jino Bak;Cho, Kwang-Hwan;Chu, Sung-Sil;Lee, Chang-Geol;Lee, Suk;Hongryll Pyo;Suh, Chang-Ok
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.181-186
    • /
    • 2002
  • The IMRT planning depends on the algorithm of each planning system and MLC performance of each Linac system. Yonsei Cancer Center introduced an IMRT System at the beginning of February, 2002. The system consists of CORVUS (Nomos, U.S.A.) treatment planning system, LANTIS, PRIMEVIEW and PRIMART (Siemens, U.S.A) linac system. The optimization of CORVUS planning system with PRIMART is an important task to make a desirable quality treatment plan. Our Step & Shoot IMRT system uses Finite Size Pencil Beams (FSPB) dose model, simulated annealing optimization algorithm and IMFAST segmentation algorithm. We constructed treatment plans for four different patient cases with two basic beamlet sizes, 1.0$\times$1.0 $\textrm{cm}^2$ and 0.5$\times$1.0 $\textrm{cm}^2$, and four intensity steps, 5%, 10%, 20%, 33%. Each case's plan was evaluated with the dose volume histograms of target volumes and delivery efficiencies. The patient case of small target volume is sensitive at the change of intensity map's segmentation and it highlighted an effective treatment plan at marrow intensity step and small basic projection beamlet.

  • PDF

Usefulness of Gated RapidArc Radiation Therapy Patient evaluation and applied with the Amplitude mode (호흡 동조 체적 세기조절 회전 방사선치료의 유용성 평가와 진폭모드를 이용한 환자적용)

  • Kim, Sung Ki;Lim, Hhyun Sil;Kim, Wan Sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.29-35
    • /
    • 2014
  • Purpose : This study has already started commercial Gated RapidArc automation equipment which was not previously in the Gated radiation therapy can be performed simultaneously with the VMAT Gated RapidArc radiation therapy to the accuracy of the analysis to evaluate the usability, Amplitude mode applied to the patient. Materials and Methods : The analysis of the distribution of radiation dose equivalent quality solid water phantom and GafChromic film was used Film QA film analysis program using the Gamma factor (3%, 3 mm). Three-dimensional dose distribution in order to check the accuracy of Matrixx dosimetry equipment and Compass was used for dose analysis program. Periodic breathing synchronized with solid phantom signals Phantom 4D Phantom and Varian RPM was created by breathing synchronized system, free breathing and breath holding at each of the dose distribution was analyzed. In order to apply to four patients from February 2013 to August 2013 with liver cancer targets enough to get a picture of 4DCT respiratory cycle and then patients are pratice to meet patient's breathing cycle phase mode using the patient eye goggles to see the pattern of the respiratory cycle to be able to follow exactly in a while 4DCT images were acquired. Gated RapidArc treatment Amplitude mode in order to create the breathing cycle breathing performed three times, and then at intervals of 40% to 60% 5-6 seconds and breathing exercises that can not stand (Fig. 5), 40% While they are treated 60% in the interval Beam On hold your breath when you press the button in a way that was treated with semi-automatic. Results : Non-respiratory and respiratory rotational intensity modulated radiation therapy technique absolute calculation dose of using computerized treatment plan were shown a difference of less than 1%, the difference between treatment technique was also less than 1%. Gamma (3%, 3 mm) and showed 99% agreement, each organ-specific dose difference were generally greater than 95% agreement. The rotational intensity modulated radiation therapy, respiratory synchronized to the respiratory cycle created Amplitude mode and the actual patient's breathing cycle could be seen that a good agreement. Conclusion : When you are treated Non-respiratory and respiratory method between volumetric intensity modulated radiation therapy rotation of the absolute dose and dose distribution showed a very good agreement. This breathing technique tuning volumetric intensity modulated radiation therapy using a rotary moving along the thoracic or abdominal breathing can be applied to the treatment of tumors is considered. The actual treatment of patients through the goggles of the respiratory cycle to create Amplitude mode Gated RapidArc treatment equipment that does not automatically apply to the results about 5-6 seconds stopped breathing in breathing synchronized rotary volumetric intensity modulated radiation therapy facilitate could see complement.

MU Fluence Reconstruction based-on Delivered Leaf Position: for IMRT Quality Assurance (세기조절방사선치료의 정도관리를 위한 모니터유닛 공간분포 재구성의 효용성 평가)

  • Park, So-Yeon;Park, Yang-Kyun;Park, Jong-Min;Choi, Chang-Heon;Ye, Sung-Joon
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.1
    • /
    • pp.28-34
    • /
    • 2011
  • The measurement-based verification for intensity modulated radiation therapy (IMRT) is a time-and labor-consuming procedure. Instead, this study aims to develop a MU fluence reconstruction method for IMRT QA. Total actual fluences from treatment planning system (TPS, Eclipse 8.6, Varian) were selected as a reference. Delivered leaf positions according to MU were extracted by the dynalog file generated after IMRT delivery. An in-house software was develop to reconstruct MU fluence from the acquired delivered leaf position data using MATLAB. We investigated five patient's plans delivered by both step-and-shoot IMRT and sliding window technologies. The total actual fluence was compared with the MU fluence reconstructed by using commercial software (Verisoft 3.1, PTW) and gamma analysis method (criteria: 3%/3 mm and 2%/1 mm). Gamma pass rates were $97.8{\pm}1.33$% and the reconstructed fluence was shown good agreement with RTP-based actual fluence. The fluence from step and shoot IMRT was shown slightly higher agreement with the actual fluence than that from sliding window IMRT. If moving from IMRT QA measurements toward independent computer calculations, the developed method can be used for IMRT QA. A point dose calculation method from reconstructed fluences is under development for the routine IMRT QA purpose.