• Title/Summary/Keyword: 성능 위험

Search Result 1,192, Processing Time 0.031 seconds

The Accident Risk Detection System in Dashcam Video using Object Detection Algorithm (물체 탐지 알고리즘을 활용한 블랙박스 영상 내 사고 위험 감지 시스템)

  • Hong, Jin-seok;Han, Myeong-woo;Kim, Jeong-seon;Kim, Kyung-sup
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.364-368
    • /
    • 2018
  • In this paper, we use Faster R-CNN that is one of object detection algorithm and OpenCV that purposes computer vision, to implement the system that can detect danger when a vehicle attempts to change lanes into its own lane in videos of highway, national road, general road and etc. Also, the performance of implemented system is evaluated to prove that the performance is not bad.

  • PDF

실습선 한바다호의 운항성능에 관한 연구( I );선체감시장치 (HMS) 계측 데이터를 이용한 내항성능 평가

  • Jeong, Chang-Hyeon;Lee, Hyeong-Gi;Lee, Yun-Seok
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2007.12a
    • /
    • pp.31-33
    • /
    • 2007
  • 최근에 선박이 대형화, 고속화되면서 선수 충격파 영향으로 인하여 선체 또는 화물에 잦은 손상을 초래하기도 하고, 극단적인 상황에서는 선박이 절단되기도 한다. 본 논문에서는 내항성능 평가요소 중 하나인 상하가속도 값을 선교에 설치된 선체감시장치를 이용하여 해상상태별 변화량을 계측하고, 이를 모형시험 및 이론계산 결과와 상호 비교하였다. 또한 ITTC 에서 제시하는 내항성능 기준치와도 비교함으로써 실습선 한바다호의 내항성능을 확인하였다. 이러한 결과는 앞으로 경험할 수 있는 다양한 해상상태에서의 작업가능성 및 위험성 정도의 예측을 가능하게 함으로써 선박의 안전운항에 큰 도움이 될 것으로 판단되며, 또한 다양한 실선계측 자료를 통하여 조선소에서는 보다 우수한 성능의 선박 건조가 가능하리라 본다.

  • PDF

Categorizing Safety Management Elements for Fire Preparation and Assessemnt of Fire Hazard (화재에 대비한 지하공간의 안전관리 요소분류 및 화재위험성 평가방안)

  • Bae, Yoonshin;Park, Jihye
    • Journal of the Society of Disaster Information
    • /
    • v.7 no.2
    • /
    • pp.96-109
    • /
    • 2011
  • In this study, risk categorized five safety management elements(equipment and structure, evacuation, lifesaving and fire extinguishing, performance based fire safety plan, operations management) were classified in order to establish safety system of underground space. Using classified safety management elements, assessment of fire hazard was performed. After calculating the grade of evaluation categories, assessment of fire hazard was suggested. The three grades of evaluation categories are classified as to importance and four criteria of evaluation are classified as to check result based on subdivisions.

Design and Implementation of Quantitative Risk Analysis System for ISP Network (ISP(Internet Service Provider) 네트워크의 정량적인 위험분석을 위한 시스템 설계 및 구현)

  • 문호건;최진기;김형순
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.14 no.2
    • /
    • pp.101-111
    • /
    • 2004
  • Risk analysis process, which identifies vulnerabilities and threat causes of network assets and evaluates expected loss when some of network assets are damaged, is essential for diagnosing ISP network security levels and response planning. However, most existing risk analysis systems provide only methodological analysis procedures, and they can not reflect continually changing vulnerabilities and threats information of individual network system on real time. For this reason, this paper suggests new system design methodology which shows a scheme to collects and analyzes data from network intrusion detection system and vulnerability analysis system and estimate quantitative risk levels. Additionally, experimental performance of proposed system is shown.

Evaluation of The Hygrothermal Performance by Wall Layer Component of Wooden Houses Using WUFI Simulation Program (WUFI 시뮬레이션 프로그램을 이용한 목조주택 벽체 레이어 구성에 따른 hygrothermal 성능 평가)

  • Kang, Yujin;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.1
    • /
    • pp.75-84
    • /
    • 2016
  • Thermal performance of wooden houses used by building materials effectively contributing to building energy saving has been improved. However, the performance was decreased to the condensation and mould growth from exterior wall because the moisture control was difficult to high insulation and airtightness. Therefore, the hygrothermal performance of exterior wall, that selected 5 types of wooden houses, evaluated using the hygrothermal simulation program: heat and moisture behavior, condensation and mould growth risk. Wooden houses were selected Rural houses standard plans '10 and '14, $2^{{\prime}{\prime}}{\times}6^{{\prime}{\prime}}$ type, EIFS and wood-based passive house. And the wall A, B, C, D and E were determined by layer component of each wall. The U-value of exterior wall are 0.171, 0.172, 0.221, 0.150, $0.079W/m^2K$. The OSB absolute water content of the wall A and C was exceeds the reference value of 20%, and it was confirmed that condensation occur at insulation material inner surface through the condensation evaluation in the winter. The wall D and E showed excellent results with condensation and water content evaluation compared to others. However, mould growth risk assessment in all five types of wall had have risk. We were determined that hygrothermal performance difference of exterior wall occur the difference in the layer structure rather than in thermal performance.

An Experimental Study on the Radiant Heat of the Firedoors in Fire (화재시 방화문의 복사열에 관한 실험적 연구)

  • Jeon, Jun-Pyo;Jeon, Soo-Min;Cho, Nam-Wook;In, Ki-Ho;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.8-13
    • /
    • 2011
  • The fire compartments which are composed of fire walls and fire doors for buildings are compulsorily required to minimize the fire damage in Korea. The performance standards of fire doors for compartments are regulated by the notification of the ministry of land, transport and maritime affairs and are mainly about the Integrity of the doors not insulation. In this study, we measured the radiant heat of six different kinds of fire doors in fire and analyzed the results and presented the reasons of the need to consider adding the radiant heat standard for fire doors to the notification.