• Title/Summary/Keyword: 성능기반내진설계

Search Result 106, Processing Time 0.028 seconds

Seismic Performance Evaluation of SRC Composite Column using Direct Displacement Based Design Method (직접변위기반 설계법에 의한 SRC 합성기둥의 내진성능평가)

  • Jung, In-Kju;Park, Soon-Eung;Kim, Dong-Hyuk
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.3
    • /
    • pp.63-70
    • /
    • 2012
  • In this study, the displacement-based design concept, the performance by the existing reinforced concerte column and steel reinforced concrete composite column for SRC purchased the maximum design ground acceleration improvement compared to the performance design. SRC have several advantages such as strength enhancement and high ductility. H-beam or steel tubes were used for embedded elements of the SRC composite columns. SRC cross-section for the P-M diagram and analysis on the nominal bending monent SRC designed for composite columns for disparity estimation is presented to the displacement-based seismic design. Performance improvement of the performance-based design performance targets for the design seismic displacement and design criteria for the direct displacement-based design methods and to improve the seismic performance due to the displacement coefficient method is proposed to design. SRC compared with the RC column designed to improve the performance and displacement ductility ratio displacement results in the performance design results showed significantly improved performance.

Seismic Performance-Based Design for Breakwater (방파제의 성능기반 내진설계법)

  • Kim, Young-Jun;Park, Inn-Joon
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.12
    • /
    • pp.91-101
    • /
    • 2022
  • The 1995 Kobe earthquake caused a massive damage to the Port of Kobe. Therefore, it was pointed out that it was impossible to design port structures for Level II (Mw 6.5) earthquakes with quasi-static analysis and Allowable Stress Design methods. In Japan and the United States, where earthquakes are frequent, the most advanced design standards for port facilities are introduced and applied, and the existing seismic design standards have been converted to performance-based design. Since 1999, the Korean Port Seismic Design Act has established a definition of necessary facilities and seismic grades through research on facilities that require seismic design and their seismic grades. It has also established a performance-based seismic design method based on experimental verification. In the performance-based seismic design method of the breakwater proposed in this study, the acceleration time history on the surface of the original ground was subjected to a fast Fourier transform, followed by a filter processing that corrected the frequency characteristics corresponding to the maximum allowable displacement with respect to performance level of the breakwater and the filtered spectrum. The horizontal seismic coefficient for the equivalent static analysis considering the displacement was calculated by inversely transforming (i.e., subjected to an inverse fast Fourier transform) into the acceleration time history and obtaining the maximum acceleration value. In addition, experiments and numerical analysis were performed to verify the performance-based seismic design method of breakwaters suitable for domestic earthquake levels.

Seismic Performance Improved Design of Reinforced Concrete Columns Strengthened by Steel Jackets Using Displacement-based Design (스틸재킷 보강 철근콘크리트 기둥의 변위기반 내진 성능 개선 설계 방법)

  • Jung, In-Kju;Park, Moon-Ho;Cho, Chang-Geun
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.1
    • /
    • pp.11-18
    • /
    • 2010
  • In this study, a procedure of performance-based design for the seismic retrofit of reinforced concrete columns strengthened by steel jackets has been presented. In order to predict the target displacement of retrofitted columns, a nonlinear analysis of reinforced concrete columns retrofitted with steel jackets has been developed based on a segmental model with the fiber cross-sectional approach. The seismic displacement level of retrofitted columns is estimated both by the direct displacement-based design method and by the displacement coefficient method. In examples of seismic retrofitted columns, the current seismic retrofit procedure gives good results in improvements of displacement levels and displacement ductilities of retrofitted columns.

Performance based seismic design for the seismic evaluation of cable-stayed bridges (성능기반 내진설계법을 이용한 사장교의 지진해석)

  • Kwak, Hyo-Gyoung;Shin, Dong-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.461-462
    • /
    • 2009
  • Since the modal pushover analysis (MPA) is introduced by A.K.Chopra in 2002, it has been the leading procedure for the seismic evalution of structures. However it has scarcely used on bridge structures dueing to its inherent limitation. In this paper, MPA is applied on cable-stayed bridges to check its applicability on such structures.

  • PDF

Displacement Based Seismic Performance Improved Design of RC Column Retrofitted Steel Jacket (변위기반 설계법에 의한 RC 기둥의 Steel Jacket 보강 내진성능개선 설계법)

  • Jung, In-Kju;Cho, Chang-Geun;Park, Soon-Eung
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.4
    • /
    • pp.49-57
    • /
    • 2010
  • This study is the research appling the representative Displacement-Based Design which is the basic concept of Direct Displacement Based Design proposed by Chopra and Goel to original Reinforced Concrete structure and determining the thickness of retrofit Steel Jacket about the Maximum design ground acceleration, and developing the more improved Algorithm as well as program by the Retrofit Design method and Nonlinear analysis by the Performance design method before and after reinforcement appling the determined retrofit thickness. To predict the target displacement of retrofitted columns, a nonlinear analysis model of reinforced concrete columns has been developed to be based on the nonlinear fiber cross-sectional and segmental analysis model, and the seismic displacement level of retrofitted columns is estimated by two procedures, the direct displacement-based design method and the displacement coefficient method. In examples of seismic retrofit design, the current seismic improved design method gives good results in improvements of displacement levels and displacement ductilities of retrofitted columns.

  • PDF

Evaluation of Seismic Performance for Bridge Using Capacity Spectrum Method (역량스펙트럼을 이용한 교량의 내진성능평가)

  • Park, Yeon-Soo;Choi, Sun-Min;Kin, Eung-Rok;Suh, Byoung-Chul
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.448-455
    • /
    • 2007
  • In 1992, the first design standard of quake proof bridge was established. However, most bridge structures which were constructed without considering earthquake in former times need performance of quakeproof property. Quakeproof analysis in current bridges, is based on analysis of load base which just has strength over the load of simple structures but is not checked through simple comparison of strength performance of structures so that we would like to check that ADRS method is reasonable or not using ADRS method(Accleration-Displacement Response Spectrum Method), a analysis method based on displacement of object of performance test. As the result of that, the capacity spectrum method can avoid complex dynamic analysis in analysis based on loads and it efficiently applies to design verification with normal checking for quakeproof performance and aimed performance of new structures. However we can not consider effects of high modes and it has problem that does not consider falling of performance in structures by repeated load.

  • PDF

Seismic Behavior Characteristics of Spherical Storage Tanks Supported by Inelastic Members and Performance-Based Seismic Design Based on Reliability (비선형지지구조 저장탱크의 지진거동 특성과 신뢰도 기반의 성능기반 내진설계)

  • Jang jeong min;Sun chang ho;Kim ick hyun;Choi jeong in
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.4
    • /
    • pp.27-33
    • /
    • 2023
  • In a petrochemical plant, various mechanical equipments and structures are interconnected to ensure operability. Since the production activities of petrochemical plants have a great impact on the national economy, it is very important to maintain not only structural safety but also the operability of the facilities. However, the current seismic design standards present the design requirements of facilities mainly aimed at preventing collapse, and do not provide the requirements for securing operability of facilities. Depending on the behavioral characteristics of the facility, operability of the facility can be secured by seismic performance levels other than the collapse prevention level, so it is necessary to present seismic design methods that can apply various seismic performance levels. Spherical (ball) storage tanks are supported by columns and braces and exhibit complex nonlinear behavior because of buckling and yielding of support members. In this study, nonlinear seismic behavior characteristics were statistically analyzed and a new performance-based seismic design method was proposed based on them.

Seismic Capacity Evaluation of Bridge Structure using Capacity Spectrum Method (역량스펙트럼법에 의한 교량 구조물의 내진성능평가)

  • 박연수;오백만;박철웅;서병철
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.5
    • /
    • pp.67-73
    • /
    • 2003
  • The present seismic analysis of Road-Bridge Design Standard is on a basis of load-based analysis which lets structures have the strength over load. In this study, the capacity spectrum method, a kind of displacement based method, which is evaluated by displacement of structure, is presented as an alternative to the analysis method based on load. Seismic capacity is performed about the existing reinforced concrete pier which has already secured seismic design by capacity spectrum method. As a result. capacity spectrum method could realistically evaluate the non-elastic behavior of structures easily and quickly and the displacement of structures for variable ground motion level. And it could efficiently apply to an evaluation of seismic capacity about the existing structure and a verification of design for capacity target of the new structure.

Development of Performance-Based Seismic Design of RC Column Retrofitted By FRP Jacket using Direct Displacement-Based Design (직접변위기반설계법에 의한 철근콘크리트 기둥의 FRP 피복보강 내진성능설계법의 개발)

  • Cho, Chang-Geun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.2 s.54
    • /
    • pp.105-113
    • /
    • 2007
  • In the current research, an algorithm of performance-based seismic retrofit design of reinforced concrete columns using FRP jacket has been proposed. For exact prediction of the nonlinear flexural analysis or FRP composite RC members, multiaxial constitutive laws of concrete and composite materials have been presented. For seismic retrofit design, an algorithm of direct displacement-based design method (DDM) proposed by Chopra and Goel (2001) has been newly applied to determine the design thickness of FRP jacket in seismic retrofit of reinforced concrete columns. To compare with the displacement coefficient method (DCM), the DDM gives an accurate prediction of the target displacement in highly nonlinear region, since the DCM uses the elastic stiffness before reaching the yield load as the effective stiffness but the DDM uses the secant stiffness.

Development of Performance-Based Seismic Design of RC Column Using FRP Jacket by Displacement Coefficient Method (FRP 보강 철근콘크리트기둥의 변위계수법에 의한 내진성능설계기법 개발)

  • Cho, Chang-Geun;Ha, Gee-Joo;Bae, Su-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.491-497
    • /
    • 2007
  • In the current research, the scheme of displacement-based seismic design for seismic retrofit of concrete structures using FRP composite materials has been proposed. An algorithm of the nonlinear flexural analysis of FRP composite concrete members has been presented under multiaxial constitutive laws of concrete and composite materials. An algorithm for performance-based seismic retrofit design of reinforced concrete columns with FRP jacket has been newly introduced to modify the displacement coefficient method used in reinforced concrete structures. From applications of retrofit design, the method are easy to apply in the practice of retrofit design and give practical prediction of nonlinear seismic performance evaluation of retrofitted structures.